References
- E. O. Doeblin, Measurement System and Application and Design. 4th ed. New York, NY: McGraw-Hill, 1990.
- B. G. Liptak, Process Measurement and Analysis. 4th ed. Oxford: Butterworth Heinman Ltd, 2003.
- D. Patranabis. Principle of Industrial Instrumentation. 3rd. New Delhi: Tata McGraw Hill, 2010.
- W. Bolton. Instrumentation and Control Systems. Newnes: Elsevier, 2nd ed. 2015.
- V. Tanyildizi, and H. Eren, “A new production technique for rotameters and venturimeters”, Measurement, Elsevier, Vol. 39, pp. 674–679, 7 Aug. 2006. doi: https://doi.org/10.1016/j.measurement.2005.12.011
- S. C. Bera, and H. Mandal, “A flow measurement technique using a Noncontact capacitance type orifice transducer for a conducting liquid,” IEEE Trans. Instrum. Meas., Vol. 61, no. 9, pp. 2553–2559, Sept. 2012. doi: https://doi.org/10.1109/TIM.2012.2192345
- S. Marick, S. K. Bera, and S. C. Bera, “A modified technique of flow transducer using bourdon tube as primary sensing element,” IEEE Sensors J., Vol. 14, no. 9, pp. 3033–3039, Sept. 2014. doi: https://doi.org/10.1109/JSEN.2014.2322199
- K. J. Kumaresh, P. Deepak Raj, and M. Sridharan, “Design of thin film capacitive sensor for flow measurement,” Recent Adv. Nano Sci. Technol., Vol. 3, pp. 1517–1524, 2015. 2016.
- R. C. Baker. Flow measurement Handbook. New York: Cambridge University Press, 2000.
- R. C. Baker, “The impact of component variation in the manufacturing process on variable area (VA) flowmeter performance,” Flow Meas. Instrum., Vol. 15, pp. 207–213, 2004. doi: https://doi.org/10.1016/j.flowmeasinst.2004.03.002
- T. Zhang, H. Wang, and D. Chen, “Smart floating element flowmeter based on a capacitive angular displacement transducer,” Flow Meas. Instrum., Vol. 16, pp. 1–6, 2005. doi: https://doi.org/10.1016/j.flowmeasinst.2004.08.001
- X. Li, Y. Liang, L. Fang, Q. He, and Y. Zhang, “The Reasearch on inductive gas rotameter transmission system,” Elsevier AASRI Procedia, Vol. 3, pp. 284–290, 2012. doi: https://doi.org/10.1016/j.aasri.2012.11.046
- B. Mo, F. Y. Jiang, and H. X. Zhang, “The Electronic part of the metal tube rotameter,” Applied Mechanics and Materials, Vol. 419, pp. 661–666, 2013. doi: https://doi.org/10.4028/www.scientific.net/AMM.419.661
- N. Mandal, B. Kumar, R. Sarkar, and S. C. Bera, “Design of a flow transmitter using an improved inductance bridge network and rotameter as sensor,” IEEE Trans. Instrument. Meas., Vol. 63, no. 12, pp. 3127–3136, Dec. 2014. doi: https://doi.org/10.1109/TIM.2014.2326770
- N. Mandal, B. Kumar, G. Rajita and B. Mondal, “A modified design of a flow transmitter using rotameter as a primary sensor and LVDT as a transducer,” Proceedings of the 2014 International Conference on Control, Instrumentation, Energy and Communication (CIEC), Calcutta, 2014.
- S. Sinha, D. Banerjee, N. Mandal, R. Sarkar and S.C. Bera, “Design and Implementation of Real-time flow measurement system using hall probe sensor and PC-based SCADA”, IEEE Sensors J., Vol. 15, no. 10, pp.5592–5599, Oct. 2015. doi: https://doi.org/10.1109/JSEN.2015.2442651
- C. N. Deepu, Y. Kumar, and V. Seshadri, “Design Analysis for. rotameter using CFD,” Int. J. Eng. Sci. Res. Technol., Vol. 5, pp. 305–312, 2015.
- T.-Z. Wei-Jiang, Y. Xu, X.-G. Huaxiang Wang, and P.-S. Jing-Lei, “The Effects of fluid viscosity on the orifice rotameter,” Meas. Sci. Rev., Vol. 16, pp. 87–95, 2016. doi: https://doi.org/10.1515/msr-2016-0012
- B. Kumar, S. K. Bera, and N. Mandal, “Design and development of an Electro-Optic type-flow transmitter using Mach–Zehnder interferometer,” IEEE Trans. Instrum. Meas., Vol. 65, no. 7, pp. 1716–1723, Jul. 2016. doi: https://doi.org/10.1109/TIM.2016.2540886
- J. Chen, X. Zheng, B. Li, Y. Cao, and N. Fan, “Study on magnetoresistive rotameter with high precision,” Flow Meas. Instrum., Vol. 58, pp. 120–119, 2017. doi: https://doi.org/10.1016/j.flowmeasinst.2017.09.015
- N. Mandal, and G. Rajita, “An accurate technique of measurement of flow rate using rotameter as a primary sensor and an improved op-amp based network,” Flow Meas. Instrum., Vol. 58, pp. 38–45, 2017. doi: https://doi.org/10.1016/j.flowmeasinst.2017.09.014