Performance Evaluation of ILC Controller for Anesthesia Process

, &

References

  • J. Y. Lan, M. F. Abbod, R.-G. Yeh, S.-Z. Fan, and J.-S. Shieh, “Intelligent modeling and control in anesthesia,” J. Med. Biol. Eng., Vol. 32, no. 5, pp. 293–308, 2012. DOI:10.5405/jmbe.1014
  • A. Savoca, and D. Manca, “A physiologically-based approach to model-predictive control of anesthesia and analgesia,” Biomed. Signal. Process. Control., Vol. 53, pp. 1–12, 2019. DOI:10.1016/j.bspc.2019.04.030
  • C. Rosow, and P. J. Manberg, “Bispectral index monitoring,” Anesthesiol Clin North Am, Vol. 19, no. 4, pp. 947–51, 2001. DOI:10.1016/S0889-8537(01)80018-3
  • C. Ionescu, J. Tenreiro Machado, R. De Keyser, J. Decruyenaere, and M. M. R. F. Struys, “Nonlinear dynamics of the patient’s response to drug effect during general anesthesia,” Communications Nonlinear Science Numerical Simulation, Vol. 20, pp. 914–26, 2015. DOI:10.1016/j.cnsns.2014.05.014
  • J. W. Johansen, P. S. Sebel, and D. M. Fisher “Development and clinical application electroencephalographic bispectrum monitoring,” Anesthesiology, Vol. 93, pp. 1336–44, 2000. DOI:10.1097/00000542-200011000-00029
  • H. Vierto-Oja, et aln., “Description of the entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy module,” Acta Anaesth. Scand., Vol. 48, pp. 154–61, 2004. DOI:10.1111/j.0001-5172.2004.00322.x
  • S. Bibian, G. A. Dumont, and T. Zikov, “Dynamic behavior of BIS, M-entropy and neuroSENSE brain function monitors,” J. Clin. Monit. Comput., Vol. 25, pp. 81–7, 2011. DOI:10.1007/s10877-010-9266-9
  • E. W. Jensen, et al., “Cerebral state index during propofol anesthesia: A comparison with the Bispectral index and the A-line ARX index,” Anesthesiology, Vol. 105, pp. 28–36, 2006. DOI:10.1097/00000542-200607000-00009
  • H. Litvan, et al., “Comparison of auditory evoked potentials and the A-line ARX index for monitoring the hypnotic level during sevofluane and propofol induction,” Acta Anaesth. Scand., Vol. 46, pp. 245–51, 2002. DOI:10.1034/j.1399-6576.2002.t01-1-460304.x
  • J. Bruhn, T. Bouillon, and S. L. Shafer, “Bispectral index (BIS) and burst suppression: revealing a part of the BIS algorithm,” J. Clin. Monit. Comput., Vol. 16, pp. 593–96, 2000. DOI:10.1023/A:1012216600170
  • J. W. Johansen, “Update on bispectral index monitoring,” Best Practice and Research: Clinical Anaesthesiology, Vol. 20, pp. 81–99, 2006. DOI:10.1016/j.bpa.2005.08.004
  • I. A. Iselin-Chaves, et al., “The effect of the interaction of propofol and alfentanil on recall, loss of consciousness, and the bispectral index,” Anesth. Analg., Vol. 87, pp. 949–55, 1998. DOI:10.1213/00000539-199810000-00038
  • T. J. Gan, P. S. Glass, A. Windsor, F. Payne, C. Rosow, P. Sebel, and P. Manberg, “Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia,” Anesthesiology, Vol. 87, pp. 808–15, 1997. DOI:10.1097/00000542-199710000-00014
  • A. Ekman, M. L. Lindholm, C. Lennmarken, and R. Sandin, “Reduction in the incidence of awareness using BIS monitoring,” Acta Anaesth. Scand., Vol. 48, pp. 20–6, 2004. DOI:10.1111/j.1399-6576.2004.00260.x
  • P. S. Myles, K. Leslie, J. McNeil, A. Forbes, and M. T. V. Chan, “Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial,” The Lancet, Vol. 363, pp. 1757–63, 2004. DOI:10.1016/S0140-6736(04)16300-9
  • J. W. Johansen, P. S. Sebel, and J. C. Sigl, “Clinical impact of hypnotic-titration guidelines based on EEG bispectral index (BIS) monitoring during routine anesthetic care,” J. Clin. Anesth., Vol. 12, pp. 433–43, 2000. DOI:10.1016/S0952-8180(00)00187-2
  • S. Abdulla, and P. Wen, “Depth of anaesthesia patient models and control,” in Proceedings of the 2011 IEEEIICME International Conference on Complex Medical Engineering May 22–25, Harbin, China, 2011, pp. 37–41.
  • J. M. Bailey, and W. M. Haddad, “Drug dosing control in clinical pharmacology,” IEEE Control Syst. Mag., Vol. 25, no. 2, pp. 35–51, 2005. DOI:10.1109/MCS.2005.1411383
  • A. R. Absalom, R. De Keyser, and M. M. R. F. Struys, “Closed loop anaesthesia: are we getting close to finding the Holy Grail,” Anesth. Analg, Vol. 112, pp. 516–8, 2011. DOI:10.1213/ANE.0b013e318203f5ad
  • C. H. Ting, R. H. Arnott, D. A. Linkens, and A. Angel, “Migrating from target-controlled infusion to closed-loop control in general anesthesia,” Computer Methods Programs Biomed, Vol. 75, pp. 127–39, 2004. DOI:10.1016/j.cmpb.2003.11.005
  • Y. Wang, Y. Yang, and Z. Zhao, “Robust stability analysis for an enhanced ILC-based PI controller,” J. Process Contr., Vol. 23, pp. 201–14, 2013. DOI:10.1016/j.jprocont.2012.08.004
  • S. Arimoto, S. Kawamura, and F. Miyazaki, “Bettering operation of robots by learning,” J. Robot. Syst., Vol. 1, pp. 123–40, 1984. DOI:10.1002/rob.4620010203
  • Y. Chen, K. L. Moore, and V. Bahl, “Improved path following of USUODIS by learning feedforward controller using B-spline network,” in Proceedings of the IEEE International Symposium on Computational Intelligence Robotics Automation, Banff, Canada, 2001, pp. 59–64.
  • D. De Roover, “Synthesis of a robust iterative learning controller using an approach,” in Proceedings of the Conference on Decision Control, Kobe, Japan, 1996, pp. 3044–49.
  • T. J. A. Devries, W. J. R. Velthuis, and J. Van Amerongen, “Learning feedforward control: A survey and historical note,” in Proceedings of the IFAC Conference on Mechatronic Systems, Darmstadt, Germany, 2000, pp. 949–54.
  • T. Y. Doh, J. H. Moon, K. B. Jin, and M. J. Chung, “Robust ILC with current feedback for uncertain linear systems,” Int. J. Syst. Sci., Vol. 30, pp. 39–47, 1999. DOI:10.1080/002077299292650
  • L. Merigoa, F. Padula, N. Latronico, M. Paltenghi, and A. Visioli, “Optimized PID control of propofol and remifentanil coadministration for general anesthesia,” Commun. Nonlinear Sci. Numer. Simulat., Vol. 72, pp. 194–212, 2019. DOI:10.1016/j.cnsns.2018.12.015
  • L. Merigoa, et al., “A model-based control scheme for depth of hypnosis in anesthesia,” Biomed. Signal. Process. Control., Vol. 42, pp. 216–29, 2018. DOI:10.1016/j.bspc.2018.01.023
  • I. Martín-Mateos, J. A. Méndez Pérez, J. A. Reboso Morales, and J. F. Gómez-González, “Adaptive pharmacokinetic and pharmacodynamic modelling to predict propofol effect using BIS-guided anesthesia,” Comput. Biol. Med., Vol. 75, pp. 173–80, 2016. DOI:10.1016/j.compbiomed.2016.06.007
  • F. Padula, C. Ionescu, N. Latronico, M. Paltenghi, A. Visioli, and G. Vivacqua, “Optimized PID control of depth of hypnosis in anesthesia,” Comput. Methods Programs Biomed., Vol. 144, pp. 21–35, 2017. DOI:10.1016/j.cmpb.2017.03.013
  • T. W. Schnider, C. F. Minto, S. L. Shafer, P. L. Gambus, C. Andresen, D. B. Goodale, and E. J. Youngs, “The influence of age on propofol pharmacodynamics,” Anesthesiology, Vol. 90, pp. 1502–16, 1999. DOI:10.1097/00000542-199906000-00003
  • Y. Sakuma, K. Sameshima, and R. Kohno, “An adaptive scheme of controlling dosage and dosing interval in general anesthesia by model predictive control using anesthetic depth model,” in 11th International Symposium on Medical Information and Communication Technology (ISMICT), 2017, pp. 77–81.
  • C. M. Ionescu, R. De Keyser, B. C. Torrico, T. De Smet, M. M. R. F. Struys, and J. E. Normey-Rico, “Robust predictive control strategy applied for propofol dosing using BIS as a controlled variable during anesthesia,” IEEE Trans. Biomed. Eng, Vol. 55, pp. 2161–70, 2008. DOI:10.1109/TBME.2008.923142
  • I. Nascu, A. Krieger, C. M. Ionescu, and E. Pistikopoulos, “Advanced model-basedcontrol studies for the induction and maintenance of intravenous anesthesia,” IEEE Trans. Biomed. Eng, Vol. 62, pp. 832–41, 2015. DOI:10.1109/TBME.2014.2365726
  • M. M. R. F. Struys, T. De Smet, S. Greenwald, A. R. Absalom, S. Binge, and E. P. Mortier, “Performance evaluation of two published closed-loop control systems using bispectral index monitoring: a simulation study,” Anesthesiology, Vol. 95, pp. 6–17, 2004. DOI:10.1097/00000542-200107000-00007
  • 451094F/Revised: February 2014 DIPRIVAN® (Propofol) INJECTABLE EMULSION, USP
  • S. Skogestad, “Probably the best simple PID tuning rules in the world,” in AIChE Annual Meeting, Reno, Nevada, 2001.
  • J. G. Ziegler, and N. B. Nichols, “Optimum settings for automatic controllers,” Trans. A.S.M.E, Vol. 64, pp. 759–768, 1942.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.