Friction and Wear Properties of a Charnley Artificial Hip Joint

Pages 389-399 | Published online: 25 Mar 2008

REFERENCES

  • Sonstegard , D. A. , Matthews , L. S. , and Kaufer , H. , “ The Surgical Replacement of the Human Knee Joint ,” Sci. Am. , 238 , 1 , pp 44 – 51 ( 1978 ).
  • Charnley , J. , “ Arthroplasty of the Hip—A New Operation ,” The Lancet , 1 , pp 1129 – 1132 ( 1961 ).
  • Charnley , J. , “ Factors in the Design of an Artificial Hip Joint ,” Proc. Inst. Mech. Eng. (London) , 181 , pt 3J , pp 104 – 111 ( 1966-67 ).
  • Amstutz , H. C. , “ Polymers as Bearing Materials for Total Hip Replacement: A Friction and Wear Analysis ,” J. Biomed. Mater. Res. , 3 , 3 , pp 547 – 568 ( 1968 ).
  • Seedhom , B. B. , Dowson , D. , and Wright , V. , “ Wear of Solid Phase Formed High Density Polyethylene in Relation to the Life of Artificial Hips and Knees ,” Wear , 24 , pp 35 – 51 ( 1973 ).
  • Miller , D. A. , et al., “ A Comparative Evaluation of the Wear of UltraHigh Molecular Weight Polyethylene Abraded by Ti-6Al-4V ,” Wear , 28 , pp 207 – 216 ( 1974 ).
  • Shen , C. and Dumbleton , J. H. , “ The Friction and Wear Behavior of Irradiated Very High Molecular Weight Polyethylene ,” Wear , 30 , pp 349 – 364 ( 1974 ).
  • Beutler , H. , Lehmann , M. , and Stahli , G. , “ Wear Behavior of Medical Engineering Materials ,” Wear , 33 , pp 337 – 350 ( 1975 ).
  • Ungethum , M. , “ Requirements of Operational Tests and Test Results in Total Hip and Knee Arthroplasty. Advances in Artificial Hip and Knee Joint Technology ,” Engineering in Medicine , 2 , M. Schaldach and D. Hohmann , eds., Springer-Verlang (Berlin), 1976 , pp 493 – 518
  • Rostoker , W. and Galante , J. O. , “ Some New Studies of the Wear Behavior of Ultra-High Molecular Weight Polyethylene ,” J. Biomed. Mater. Res. , 10 , 2 , pp 303 – 310 ( 1976 ).
  • Dumbleton , J. H. and Shen , C. , “ The Wear Behavior of Ultra-High Molecular Weight Polyethylene ,” Wear , 37 , pp 279 – 289 ( 1976 ).
  • McKellop , H. , et al, “ Wear Characteristics of UHMW Polyethylene: A Method for Accurately Measuring Extremely Low Wear Rates ,” J. Biomed. Mater. Res. , 12 , 6 , pp 895 – 927 ( 1978 ).
  • Atkinson , J. R. , Brown , K. J. , and Dowson , D. , “ The Wear of High Molecular Weight Polyethylene. Part I: The Wear of Isotropic Polyethylene Against Dry Stainless Steel in Unidirectional Motion ,” J. Lubr. Technol. , 100 , 2 , pp 208 – 218 ( 1978 ).
  • Jones , W. R. , Hady , W. F. , and Crugnola , A. , “ Effect of γ-Irradiation on the Friction and Wear of Ultrahigh Molecular Weight Polyethylene ,” Wear , 70 , pp 77 – 92 ( 1981 ).
  • McKellop , H. , et al. “ Friction and Wear Properties of Polymer, Metal, and Ceramic Prosthetic Joint Materials Evaluated on a Multichannel Screening Device ,” J. Biomed. Mater. Res. , 15 , 5 , pp 619 – 653 ( 1981 ).
  • Fusaro , R. L. , “ Effect of Sliding Speed and Contact Stress on Tribological Properties of Ultra-High-Molecular-Weight Polyethylene ,” NASA TP 2059, Nov. 1982 .
  • Dumbleton , J. H. , Miller , D. A. , and Miller , E. H. , “ A Simulator for Load Bearing Joints ,” Wear , 20 , pp 165 – 174 ( 1972 ).
  • Swanson , S. A. V. , Freeman , M. A. R. , and Heath , J. C. , Laboratory Tests on Total Joint Replacement Prostheses,” J. Bone Jt. Surg. , 55B , 4 , pp 759 – 773 ( 1973 ).
  • Walker , P. S. and Salvati , E. , “ The Measurement and Effects of Friction and Wear in Artificial Hip Joints ,” J. Biomed. Mat. Res. , 7 , 3 , pp 327 – 342 ( 1973 ).
  • Weightman , B. O. , et al, “ A Comparative Study of Total Hip Replacement Prosthesis,” “ J. Biomech. , 6 , 3 , pp 299 – 311 ( 1973 ).
  • Duff-Barclay , I. and Spillman , D. T. , “ Total Human Hip Joint Protheses—A Laboratory Study of Friction and Wear ,” Proc. Inst. Mech. Eng. (London) , 181 , pt.3J , pp 90 – 103 ( 1966-67 ).
  • Clarke , I. C. , “ Wear of Artificial Joint Materials IV. Hip Joint Simulator Studies ,” Eng. Med. , 10 , 4 , pp 189 – 198 ( 1981 ).
  • Swikert , M. A. and Johnson , R. L. , “ Simulated Studies of Wear and Friction in Total Hip Prosthesis Components with Various Ball Sizes and Surface Finishes ,” NASA TND-8174, Mar. 1976 .
  • Charnley , J. , “ Low Friction Anthroplasty of the Hip Joint ,” J. Bone and Jt. Surg. , 53B , pp 149 ( 1971 ).
  • Charnley , J. and Cupric , Z. , “ The Nine and Ten Year Results of the Low Friction Anthroplasty of the Hip ,” Clin. Orthop. Relat. Res. , 95 , pp 9 – 25 ( 1973 ).
  • Charnley , J. and Halley , D. K. , “ Rate of Wear in Total Hip Replacement ,” Clin. Orthop. Relat. Res. , 112 , pp 170 – 179 ( 1975 ).
  • Rose , R. M. , et al, “ On the True Wear Rate of Ultra High-Molecular-Weight Polyethylene in the Total Hip Prosthesis ,” J. Bone Jt. Surg. , 62A , pp 537 – 549 ( 1980 ).
  • Jones , W. R. , Jr. , Roberts , J. C. , and Ling , F. F. , “ Tribological Characteristics of a Composite Total-Surface Hip Replacement ,” NASA TP-1853, Jan. 1982 .
  • Dumbleton , J. C. : Tribology of Natural and Artificial Joints, Tribology Series , 3 , Elsevier ( Amsterdam ) ( 1981 ).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.