6. References
- Nakhleh, M. K.; Amal, H.; Jeries, R.; Broza, Y. Y.; Aboud, M.; Gharra, A.; Ivgi, H.; Khatib, S.; Badarneh, S.; Har-Shai, L.; et al. Diagnosis and Classification of 17 Diseases from 1404 Subjects Via Pattern Analysis of Exhaled Molecules. ACS Nano. 2017, 11, 112–125. doi:https://doi.org/10.1021/acsnano.6b04930
- Whittle, C. L.; Fakharzadeh, S.; Eades, J.; Preti, G. Human Breath Odors and Their Use in Diagnosis. Ann. N Y Acad. Sci. 2007, 1098, 252–266. doi:https://doi.org/10.1196/annals.1384.011
- Krilaviciute, A.; Heiss, J. A.; Leja, M.; Kupcinskas, J.; Haick, H.; Brenner, H. Detection of Cancer through Exhaled Breath: A Systematic Review. Oncotarget 2015, 6, 38643–38657. doi:https://doi.org/10.18632/oncotarget.5938
- Amal, H.; Shi, D. Y.; Ionescu, R.; Zhang, W.; Hua, Q. L.; Pan, Y. Y.; Tao, L.; Liu, H.; Haick, H. Assessment of Ovarian Cancer Conditions from Exhaled Breath. Int. J. Cancer. 2015, 136, E614–E622. doi:https://doi.org/10.1002/ijc.29166
- Buszewski, B.; Kesy, M.; Ligor, T.; Amann, A. Human Exhaled Air Analytics: biomarkers of Diseases. Biomed. Chromatogr. 2007, 21, 553–566. doi:https://doi.org/10.1002/bmc.835
- Broza, Y. Y.; Haick, H. Nanomaterial-Based Sensors for Detection of Disease by Volatile Organic Compounds. Nanomedicine (Lond) 2013, 8, 785–806. doi:https://doi.org/10.2217/nnm.13.64
- Lakowicz, J. R. Principles of fluorescence spectroscopy, Springer science & business media, 2013.
- Zhang, D.; Guo, D.; Yan, K. Breath Analysis for Medical Applications; Springer: Singapore, 2017.
- Shashkova, S.; Leake, M. C. Single-Molecule Fluorescence Microscopy Review: Shedding New Light on Old Problems. Biosci. Rep. 2017, 37, BSR20170031. doi:https://doi.org/10.1042/BSR20170031
- Rao, S. S.; John, R. V.; Patil, A. K.; Unnikrishnan, V. K.; George, S. D.; Pai, K. M.; Ongole, R.; Devasia, T.; Kartha, V. B.; Chidangil, S. Optical Biopsy and Optical Pathology: Affordable Health Care under Low-Resource Settings. J. Biomed. Photon. Eng. 2020, 6, 020309–1-11. doi:https://doi.org/10.18287/JBPE20.06.020309
- Iwata, T.; Katagiri, T.; Matsuura, Y. Real-Time Analysis of Isoprene in Breath by Using Ultraviolet-Absorption Spectroscopy with a Hollow Optical Fiber Gas Cell. Sensors 2016, 16, 2058. doi:https://doi.org/10.3390/s16122058
- Kamath, S. D.; Kartha, V. B.; Mahato, K. K. Dynamics of L-Tryptophan in Aqueous Solution by Simultaneous Laser Induced Fluorescence (LIF) and Photoacoustic Spectroscopy (PAS). Spectrochim. Acta A: Mol. Biomol. Spectrosc. 2008, 70, 187–194. doi:https://doi.org/10.1016/j.saa.2007.06.041
- Mitscherling, C.; Maul, C.; Gericke, K.-H. Ultra-Sensitive Detection of Nitric Oxide Isotopologues. Phys. Scr. 2009, 80, 048122. doi:https://doi.org/10.1016/j.saa.2007.06.041
- Mitscherling, C.; Lauenstein, J.; Maul, C.; Veselov, A. A.; Vasyutinskii, O. S.; Gericke, K.-H. Non-Invasive and Isotope-Selective Laser-Induced Fluorescence Spectroscopy of Nitric Oxide in Exhaled Air. J. Breath Res. 2007, 1, 026003–1-9. doi:https://doi.org/10.1088/1752-7155/1/2/026003
- Al-Taisan, N. A. A. Cavity-Enhanced Laser-Induced Fluorescence for Real-Time Breath Acetone Monitoring; Durham University: England, 2019.
- Robert, C. Simple, Stable, and Compact Multiple-Reflection Optical Cell for Very Long Optical Paths. Appl. Opt. 2007, 46, 5408–5418. doi:https://doi.org/10.1364/AO.46.005408
- Job, V.; Patel, N.; D'Cunha, R.; Kartha, V. B. High Resolution Diode Laser Measurements on the ν2 Bands of 14NH3 and 15NH31. J. Mol. Spectrosc. 1983, 101, 48–60. doi:https://doi.org/10.1016/0022-2852(83)90005-X
- Wang, C.; Sahay, P. Breath Analysis Using Laser Spectroscopic Techniques: breath Biomarkers, Spectral Fingerprints, and Detection Limits. Sensors (Basel) 2009, 9, 8230–8262. doi:https://doi.org/10.3390/s91008230
- Tuzson, B.; Mangold, M.; Looser, H.; Manninen, A.; Emmenegger, L. Compact Multipass Optical Cell for Laser Spectroscopy. Opt. Lett. 2013, 38, 257–259. doi:https://doi.org/10.1364/OL.38.000257
- Chen, W.; Laiho, S.; Vaittinen, O.; Halonen, L.; Ortiz, F.; Forsblom, C.; Groop, P.; Lehto, M.; Metsälä, M. Biochemical Pathways of Breath Ammonia (NH3) Generation in Patients with End-Stage Renal Disease Undergoing Hemodialysis. J. Breath Res. 2016, 10, 036011. doi:https://doi.org/10.1088/1752-7155/10/3/036011
- Manne, J.; Sukhorukov, O.; Jäger, W.; Tulip, J. Pulsed Quantum Cascade Laser-Based Cavity Ring-down Spectroscopy for Ammonia Detection in Breath. Appl. Opt. 2006, 45, 9230–9237. doi:https://doi.org/10.1364/AO.45.009230
- Ai, Y.; Li, J.; Li, Q.; Sun, M.; Li, Y.; Wang, C. Cavity Ringdown Spectroscopy of Nitric Oxide in the Ultraviolet Region for Human Breath Test. J. Breath Res. 2020, 14, 037101 doi:https://doi.org/10.1088/1752-7163/ab8184
- Manfred, K. M.; Kirkbride, J. M.; Ciaffoni, L.; Peverall, R.; Ritchie, G. A. Enhancing the Sensitivity of mid-IR Quantum Cascade Laser-based Cavity-enhanced Absorption Spectroscopy Using RF Current Perturbation . Opt. Lett. 2014, 39, 6811–6814. doi:https://doi.org/10.1364/OL.39.006811
- Hamilton, D.; Orr-Ewing, A. A Quantum Cascade Laser-Based Optical Feedback Cavity-Enhanced Absorption Spectrometer for the Simultaneous Measurement of CH4 and N2O in Air. Appl. Phys. B 2011, 102, 879–890. doi:https://doi.org/10.1007/s00340-010-4259-4
- Ventrillard-Courtillot, I.; Gonthiez, T.; Clerici, C.; Romanini, D. Multispecies Breath Analysis Faster than a Single Respiratory Cycle by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy. J. Biomed. Opt. 2009, 14, 064026 doi:https://doi.org/10.1117/1.3269677
- Ciaffoni, L.; Hancock, G.; Harrison, J. J.; van Helden, J.-P. H.; Langley, C. E.; Peverall, R.; Ritchie, G. A.; Wood, S. Demonstration of a Mid-infrared Cavity Enhanced Absorption Spectrometer for Breath Acetone Detection . Anal. Chem. 2013, 85, 846–850. doi:https://doi.org/10.1021/ac3031465
- Zaidi, S. H.; Yalin, A. Method and Apparatus for Measuring Trace Levels of CO in Human Breath Using Cavity Enhanced, Mid-Infared Absorption Spectroscopy, Google Patents, 2011.
- Manne, J.; Lim, A.; Jäger, W.; Tulip, J. Off-Axis Cavity Enhanced Spectroscopy Based on a Pulsed Quantum Cascade Laser for Sensitive Detection of Ammonia and Ethylene. Appl. Opt. 2010, 49, 5302–5308. doi:https://doi.org/10.1364/AO.49.005302
- Mędrzycki, R.; Wojtas, J.; Rutecka, B.; Bielecki, Z. 2013 Detection of Nitric Oxide in Exhaled Air Using Cavity Enhanced Absorption Spectroscopy. Electron Technology Conference 2013, International Society for Optics and Photonics, pp. 89021J. doi:https://doi.org/10.1117/12.2031089
- Gianella, M.; Ritchie, G. A. Cavity-Enhanced near-Infrared Laser Absorption Spectrometer for the Measurement of Acetonitrile in Breath. Anal. Chem. 2015, 87, 6881–6889. doi:https://doi.org/10.1021/acs.analchem.5b01341
- Richard, L.; Romanini, D.; Ventrillard, I. Nitric Oxide Analysis down to Ppt Levels by Optical-Feedback Cavity-Enhanced Absorption Spectroscopy. Sensors 2018, 18, 1997. doi:https://doi.org/10.3390/s18071997
- Zheng, K.; Zheng, C.; Zhang, Y.; Wang, Y.; Tittel, F. K. Review of Incoherent Broadband Cavity-Enhanced Absorption Spectroscopy (IBBCEAS) for Gas Sensing. Sensors 2018, 18, 3646. doi:https://doi.org/10.3390/s18113646
- Henderson, B.; Khodabakhsh, A.; Metsälä, M.; Ventrillard, I.; Schmidt, F. M.; Romanini, D.; Ritchie, G. A. D.; Te Lintel Hekkert, S.; Briot, R.; Risby, T.; et al. Laser Spectroscopy for Breath Analysis: Towards Clinical Implementation. Appl. Phys. B. 2018, 124, 1–21. doi:https://doi.org/10.1007/s00340-018-7030-x
- Harren, F. J.; Cotti, G.; Oomens, J.; Te Lintel Hekkert, S. Photoacoustic Spectroscopy in Trace Gas Monitoring. In Encyclopedia of Analytical Chemistry, Robert A. Meyers, Ed.; 2000, Vol. 3; pp. 2203–2226. doi:https://doi.org/10.1002/9780470027318.a0718.pub3
- Bhat, R. A.; Mahato, K. K.; Kamath, S. D.; Ray, S.; Kartha, V. B. Photoacoustic spectroscopic studies of ovarian tissue in different pathological conditions: classification using cluster analysis. In, AACR, 2006.
- Shorter, J. H.; Nelson, D. D.; McManus, J. B.; Zahniser, M. S.; Sama, S. R.; Milton, D. K. Clinical Study of Multiple Breath Biomarkers of Asthma and COPD (NO, CO2, CO and N2O) by Infrared Laser Spectroscopy. J. Breath Res. 2011, 5, 037108. doi:https://doi.org/10.1088/1752-7155/5/3/037108
- Moeskops, B.; Naus, H.; Cristescu, S.; Harren, F. Quantum Cascade Laser-Based Carbon Monoxide Detection on a Second Time Scale from Human Breath. Appl. Phys. B. 2006, 82, 649–654. doi:https://doi.org/10.1007/s00340-005-2124-7
- Kamat, P. C.; Roller, C. B.; Namjou, K.; Jeffers, J. D.; Faramarzalian, A.; Salas, R.; McCann, P. J. Measurement of Acetaldehyde in Exhaled Breath Using a Laser Absorption Spectrometer. Appl. Opt. 2007, 46, 3969–3975. doi:https://doi.org/10.1364/AO.46.003969
- Tuzson, B.; Looser, H.; Felder, F.; Bovey, F.; Tappy, L.; Emmenegger, L. 2018 Human Breath Acetone Analysis by Mid-IR Laser Spectroscopy: Development and Application, in: Mid-Infrared Coherent Sources, Optical Society of America, pp. MT3C. doi:https://doi.org/10.1364/MICS.2018.MT3C.3
- Reyes-Reyes, A.; Horsten, R. C.; Urbach, H. P.; Bhattacharya, N. Study of the Exhaled Acetone in Type 1 Diabetes Using Quantum Cascade Laser Spectroscopy. Anal. Chem. 2015, 87, 507–512. doi:https://doi.org/10.1021/ac504235e
- Wysocki, G.; McCurdy, M.; So, S.; Weidmann, D.; Roller, C.; Curl, R. F.; Tittel, F. K. Pulsed Quantum-Cascade Laser-Based Sensor for Trace-Gas Detection of Carbonyl Sulfide. Appl. Opt. 2004, 43, 6040–6046. doi:https://doi.org/10.1364/AO.43.006040
- Patterson, C. S.; McMillan, L. C.; Stevenson, K.; Radhakrishnan, K.; Shiels, P. G.; Padgett, M. J.; Skeldon, K. D. Dynamic Study of Oxidative Stress in Renal Dialysis Patients Based on Breath Ethane Measured by Optical Spectroscopy. J. Breath Res. 2007, 1, 026005 doi:https://doi.org/10.1088/1752-7155/1/2/026005
- Skeldon, K.; McMillan, L.; Wyse, C.; Monk, S.; Gibson, G.; Patterson, C.; France, T.; Longbottom, C.; Padgett, M. Application of Laser Spectroscopy for Measurement of Exhaled Ethane in Patients with Lung Cancer. Respir. Med. 2006, 100, 300–306. doi:https://doi.org/10.1016/j.rmed.2005.05.006
- Namjou, K.; Roller, C.; Reich, T.; Jeffers, J.; McMillen, G.; McCann, P.; Camp, M. Determination of Exhaled Nitric Oxide Distributions in a Diverse Sample Population Using Tunable Diode Laser Absorption Spectroscopy. Appl. Phys. B. 2006, 85, 427–435. doi:https://doi.org/10.1007/s00340-006-2301-3
- Roller, C.; Namjou, K.; Jeffers, J. D.; Camp, M.; Mock, A.; McCann, P. J.; Grego, J. Nitric Oxide Breath Testing by Tunable-Diode Laser Absorption Spectroscopy: application in Monitoring Respiratory Inflammation. Appl. Opt. 2002, 41, 6018–6029. doi:https://doi.org/10.1364/AO.41.006018
- ten Oever, J.; Mandon, J.; Netea, M. G.; van Deuren, M.; Harren, F. J.; Cristescu, S. M.; Pickkers, P. Pulmonary Infection, and Not Systemic Inflammation, Accounts for Increased Concentrations of Exhaled Nitric Oxide in Patients with Septic shock. J. Breath Res. 2013, 7, 036003 doi:https://doi.org/10.1088/1752-7155/7/3/036003
- Metsälä, M.; Schmidt, F. M.; Skyttä, M.; Vaittinen, O.; Halonen, L. Acetylene in Breath: Background Levels and Real-time Elimination Kinetics After Smoking . J. Breath Res. 2010, 4, 046003 doi:https://doi.org/10.1088/1752-7155/4/4/046003
- Schmidt, F.; Vaittinen, O.; Metsälä, M.; Lehto, M.; Forsblom, C.; Groop, P.; Halonen, L. Ammonia in Breath and Emitted from Skin. J. Breath Res. 2013, 7, 017109. doi:https://doi.org/10.1088/1752-7155/7/1/017109
- Crosson, E. R.; Ricci, K. N.; Richman, B. A.; Chilese, F. C.; Owano, T. G.; Provencal, R. A.; Todd, M. W.; Glasser, J.; Kachanov, A. A.; Paldus, B. A.; et al. Stable Isotope Ratios Using Cavity Ring-down Spectroscopy: Determination of 13C/12C for Carbon Dioxide in Human Breath. Anal. Chem. 2002, 74, 2003–2007.,doi:https://doi.org/10.1021/ac025511d
- Halmer, D.; Basum, G. V.; Hering, P.; Mürtz, M. Mid-Infrared Cavity Leak-out Spectroscopy for Ultrasensitive Detection of Carbonyl Sulfide. Opt. Lett. 2005, 30, 2314–2316. doi:https://doi.org/10.1364/OL.30.002314
- von Basum, G.; Dahnke, H.; Halmer, D.; Hering, P.; Mürtz, M. Online Recording of Ethane Traces in Human Breath via Infrared Laser Spectroscopy. J. Appl. Physiol. (1985) 2003, 95, 2583–2590. doi:https://doi.org/10.1152/japplphysiol.00542.2003
- Halmer, D.; Thelen, S.; Hering, P.; Mürtz, M. Online Monitoring of Ethane Traces in Exhaled Breath with a Difference Frequency Generation Spectrometer. Appl. Phys. B. 2006, 85, 437–443. doi:https://doi.org/10.1007/s00340-006-2288-9
- Schmidt, F. M.; Metsälä, M.; Vaittinen, O.; Halonen, L. Background Levels and Diurnal Variations of Hydrogen Cyanide in Breath and Emitted from Skin. J. Breath Res. 2011, 5, 046004 doi:https://doi.org/10.1088/1752-7155/5/4/046004
- Keppler, F.; Schiller, A.; Ehehalt, R.; Greule, M.; Hartmann, J.; Polag, D. Stable Isotope and High Precision Concentration Measurements Confirm That All Humans Produce and Exhale methane. J. Breath Res. 2016, 10, 016003 doi:https://doi.org/10.1088/1752-7155/10/1/016003
- Heinrich, K.; Fritsch, T.; Hering, P.; Mürtz, M. Infrared Laser-Spectroscopic Analysis of 14 NO and 15 NO in Human Breath. Appl. Phys. B. 2009, 95, 281–286. doi:https://doi.org/10.1007/s00340-009-3423-1
- Blaikie, T. P.; Couper, J.; Hancock, G.; Hurst, P. L.; Peverall, R.; Richmond, G.; Ritchie, G. A.; Taylor, D.; Valentine, K. Portable Device for Measuring Breath Acetone Based on Sample Preconcentration and Cavity Enhanced Spectroscopy. Anal. Chem. 2016, 88, 11016–11021. doi:https://doi.org/10.1021/acs.analchem.6b02837
- Thorpe, M. J.; Balslev-Clausen, D.; Kirchner, M. S.; Ye, J. Cavity-enhanced Optical Frequency Comb Spectroscopy: Application to Human Breath Analysis . Opt. Express. 2008, 16, 2387–2397. doi:https://doi.org/10.1364/OE.16.002387
- Narasimhan, L.; Goodman, W.; Patel, C. K. N. Correlation of Breath Ammonia with Blood Urea Nitrogen and Creatinine during Hemodialysis. Proc. Natl. Acad. Sci. USA 2001, 98, 4617–4621. doi:https://doi.org/10.1073/pnas.071057598
- Neerincx, A. H.; Mandon, J.; van Ingen, J.; Arslanov, D. D.; Mouton, J. W.; Harren, F. J.; Merkus, P. J.; Cristescu, S. M. Real-Time Monitoring of Hydrogen Cyanide (HCN) and Ammonia (NH3) Emitted by Pseudomonas aeruginosa. J. Breath Res. 2015, 9, 027102 doi:https://doi.org/10.1088/1752-7155/9/2/027102
- Cristescu, S. M.; Kiss, R.; Te Lintel Hekkert, S.; Dalby, M.; Harren, F. J.; Risby, T. H.; Marczin, N, Harefield BIOSTRESS study investigator s Real-time Monitoring of Endogenous lipid Peroxidation by Exhaled Ethylene in Patients Undergoing Cardiac Surgery . Am. J. Physiol. Lung Cell. Mol. Physiol. 2014, 307, L509–L515. doi:https://doi.org/10.1152/ajplung.00168.2014
- Popa, C.; Patachia, M.; Banita, S.; Matei, C.; Bratu, A.; Dumitras, D. The Level of Ethylene Biomarker in the Renal Failure of Elderly Patients Analyzed by Photoacoustic Spectroscopy. Laser Phys. 2013, 23, 125701. doi:https://doi.org/10.1088/1054-660X/23/12/125701
- Neerincx, A. H.; Linders, Y. A.; Vermeulen, L.; Belderbos, R. A.; Mandon, J.; van Mastrigt, E.; Pijnenburg, M. W.; van Ingen, J.; Mouton, J. W.; Kluijtmans, L. A. Hydrogen Cyanide Emission in the Lung by Staphylococcus aureus. Eur. Respir. J. 2016, 48, 577–579. doi:https://doi.org/10.1183/13993003.02093-201
- Tuboly, E.; Szabó, A.; Erős, G.; Mohácsi, Á.; Szabó, G.; Tengölics, R.; Rákhely, G.; Boros, M. Determination of Endogenous Methane Formation by Photoacoustic Spectroscopy. J. Breath Res. 2013, 7, 046004 doi:https://doi.org/10.1088/1752-7155/7/4/046004
- Lewicki, R.; Kosterev, A. A.; Bakhirkin, Y. A.; Thomazy, D. M.; Doty, J.; Dong, L.; Tittel, F. K.; Risby, T. H.; Solga, S.; Kane, D. 2009 Real Time Ammonia Detection in Exhaled Human Breath with a Quantum Cascade Laser Based Sensor. In CLEO/QELS 2009. Conference on Lasers and Electro-Optics, 2009 and 2009 Conference on Quantum Electronics and Laser Science Conference, Baltimore, USA. IEEE, pp. 1-2. doi:https://doi.org/10.1364/CLEO.2009.CMS6
- Wang, Z.; Wang, Q.; Ching, J. Y.-L.; Wu, J. C.-Y.; Zhang, G.; Ren, W. A Portable Low-Power QEPAS-Based CO2 Isotope Sensor Using a Fiber-Coupled Interband Cascade Laser. Sens. Actuat B: Chem. 2017, 246, 710–715. doi:https://doi.org/10.1016/j.snb.2017.02.133
- Waclawek, J. P.; Moser, H.; Lendl, B. Compact Quantum Cascade Laser Based Quartz-Enhanced Photoacoustic Spectroscopy Sensor System for Detection of Carbon Disulfide. Opt. Express. 2016, 24, 6559–6571. doi:https://doi.org/10.1364/OE.24.006559
- Mueller, N. S.; Reich, S. Modeling Surface-Enhanced Spectroscopy with Perturbation Theory. Front. Chem. 2019, 7, 470. doi:https://doi.org/10.3389/fchem.2019.00470
- Centeno, R.; Mandon, J.; Harren, F. J.; Cristescu, S. M. Influence of Ethanol on Breath Acetone Measurements Using an External Cavity Quantum Cascade Laser. Photonics 2016, 3, 22. doi:https://doi.org/10.3390/photonics3020022
- Marchenko, D.; Neerincx, A.; Mandon, J.; Zhang, J.; Boerkamp, M.; Mink, J.; Cristescu, S.; Hekkert, S. t L.; Harren, F. A Compact Laser-Based Spectrometer for Detection of C2H2 in Exhaled Breath and HCN in Vitro. Appl. Phys. B. 2015, 118, 275–280. doi:https://doi.org/10.1007/s00340-014-5983-y
- Som, S.; De, A.; Banik, G. D.; Maity, A.; Ghosh, C.; Pal, M.; Daschakraborty, S. B.; Chaudhuri, S.; Jana, S.; Pradhan, M. Mechanisms Linking Metabolism of Helicobacter pylori to (18)O and (13)C-isotopes of Human Breath CO2 . Sci. Rep. 2015, 5, 10936. doi:https://doi.org/10.1038/srep10936
- Parameswaran, K. R.; Rosen, D. I.; Allen, M. G.; Ganz, A. M.; Risby, T. H. Off-Axis Integrated Cavity Output Spectroscopy with a Mid-Infrared Interband Cascade Laser for Real-Time Breath Ethane Measurements. Appl. Opt. 2009, 48, B73–B79. doi:https://doi.org/10.1364/AO.48.000B73
- Bakhirkin, Y. A.; Kosterev, A. A.; Roller, C.; Curl, R. F.; Tittel, F. K. Mid-Infrared Quantum Cascade Laser Based off-Axis Integrated Cavity Output Spectroscopy for Biogenic Nitric Oxide Detection. Appl. Opt. 2004, 43, 2257–2266. doi:https://doi.org/10.1364/AO.43.002257
- McCurdy, M. R.; Bakhirkin, Y. A.; Wysocki, G.; Tittel, F. K. Performance of an Exhaled Nitric Oxide and Carbon Dioxide Sensor Using Quantum Cascade Laser-based Integrated Cavity Output Spectroscopy . J. Biomed. Opt. 2007, 12, 034034 doi:https://doi.org/10.1117/1.2747608
- Chen, Y.; Zhang, Y.; Pan, F.; Liu, J.; Wang, K.; Zhang, C.; Cheng, S.; Lu, L.; Zhang, W.; Zhang, Z.; et al. Breath Analysis Based on Surface-Enhanced Raman Scattering Sensors Distinguishes Early and Advanced Gastric Cancer Patients from Healthy Persons. ACS Nano. 2016, 10, 8169–8179.,doi:https://doi.org/10.1021/acsnano.6b01441
- Tournié, E.; Cerutti, L. Mid-Infrared Optoelectronics: Materials, Devices, and Applications; Woodhead Publishing: Cambridge, England, 2019.
- Ma, Y. Review of Recent Advances in QEPAS-Based Trace Gas Sensing. Appl. Sci. 2018, 8, 1822. doi:https://doi.org/10.3390/app8101822
- Spacek, L. A.; Mudalel, M.; Tittel, F.; Risby, T. H.; Solga, S. F. Clinical Utility of Breath Ammonia for Evaluation of Ammonia Physiology in Healthy and Cirrhotic Adults. J. Breath Res. 2015, 9, 047109 doi:https://doi.org/10.1088/1752-7155/9/4/047109
- Spagnolo, V.; Kosterev, A.; Dong, L.; Lewicki, R.; Tittel, F. NO Trace Gas Sensor Based on Quartz-Enhanced Photoacoustic Spectroscopy and External Cavity Quantum Cascade Laser. Appl. Phys. B. 2010, 100, 125–130. doi:https://doi.org/10.1007/s00340-010-3984-z
- Arekar, S.; Daruwala, R. Development of Non-Invasive Breath Analyzer: A Proposed System for Detection of Nitric Oxide (NO) in Exhaled Human Breath, Using Infrared Quantum Cascade Laser (QCL) Absorption Technique. In: 2015 International Conference on Nascent Technologies in the Engineering Field (ICNTE), Navi Mumbai, India, IEEE, 2015, pp. 1–3. doi:https://doi.org/10.1109/ICNTE.2015.7029941
- Sampaolo, A.; Patimisco, P.; Giglio, M.; Menduni, G.; Elefante, A.; Passaro, V.; Tittel, F.; Spagnolo, V. 2019 Simultaneous Dual Gas QEPAS Sensing of Water and Methane/Nitrous Oxide. in: Quantum Sensing and Nano Electronics and Photonics XVI, International Society for Optics and Photonics, pp. 109262L. doi:https://doi.org/10.1117/12.2507922
- Maurin, N.; Rousseau, R.; Trzpil, W.; Aoust, G.; Hayot, M.; Mercier, J.; Bahriz, M.; Gouzi, F.; Vicet, A. First Clinical Evaluation of a Quartz Enhanced Photo-Acoustic CO Sensor for Human Breath Analysis. Sens. Actuat. B: Chem. 2020, 319, ) 128247. doi:https://doi.org/10.1016/j.snb.2020.128247
- Scholten, S. K.; Perrella, C.; Anstie, J. D.; White, R. T.; Al-Ashwal, W.; Hébert, N. B.; Genest, J.; Luiten, A. N. Number-Density Measurements of CO2 in Real Time with an Optical Frequency Comb for High Accuracy and Precision. Phys. Rev. Appl. 2018, 9, 054043. doi:https://doi.org/10.1103/PhysRevApplied.9.054043
- Cancio, P.; Bartalini, S.; Borri, S.; Galli, I.; Gagliardi, G.; Giusfredi, G.; Maddaloni, P.; Malara, P.; Mazzotti, D.; Natale, P. D. Frequency-Comb-Referenced mid-IR Sources for Next-Generation Environmental Sensors. Appl. Phys. B. 2011, 102, 255–269. doi:https://doi.org/10.1007/s00340-010-4216-2
- Baer, D. S.; Paul, J. B.; Gupta, M.; O'Keefe, A. Sensitive Absorption Measurements in the near-Infrared Region Using off-Axis Integrated-Cavity-Output Spectroscopy. Appl. Phys. B 2002, 75, 261–265. doi:https://doi.org/10.1007/s00340-002-0971-z
- Silva, M. L.; Sonnenfroh, D. M.; Rosen, D. I.; Allen, M. G.; Keefe, A. O. Integrated Cavity Output Spectroscopy Measurements of NO Levels in Breath with a Pulsed Room-Temperature QCL. Appl. Phys. B. 2005, 81, 705–710. doi:https://doi.org/10.1007/s00340-005-1922-2
- Hendriks, D.; Dolman, A.; Van Der Molen, M.; Van Huissteden, J. A Compact and Stable Eddy Covariance Set-up for Methane Measurements Using Off-axis Integrated Cavity Output Spectroscopy. Atmospheric Chemistry and Physics, European Geosciences Union, 2008, 8, 431–443. doi:hal-00296426.
- Widiatmono, R.; Mandon, J.; Harren, F. J.; Wasono, M. Sub Ppb CO Gas Measurement Using a Non Invasive QCL Laser Absorption Spectrometer Technique. Appl. Mech. Mater., Trans. Tech. Publ. 2015, 771, 133–136.https://doi.org/www.scientific.net/AMM.771.133.
- Pakmanesh, N.; Cristescu, S. M.; Ghorbanzadeh, A.; Harren, F. J.; Mandon, J. Quantum Cascade Laser-Based Sensors for the Detection of Exhaled Carbon Monoxide. Appl. Phys. B. 2016, 122, 10. doi:https://doi.org/10.1007/s00340-015-6294-7
- Maity, A.; Som, S.; Ghosh, C.; Banik, G. D.; Daschakraborty, S. B.; Ghosh, S.; Chaudhuri, S.; Pradhan, M. Oxygen-18 Stable Isotope of Exhaled Breath CO 2 as a Non-Invasive Marker of Helicobacter Pylori Infection. J. Anal. At. Spectrom. 2014, 29, 2251–2255. doi:https://doi.org/10.1039/C4JA00280F
- Arslanov, D. D.; Swinkels, K.; Cristescu, S. M.; Harren, F. J. Real-Time, Subsecond, Multicomponent Breath Analysis by Optical Parametric Oscillator Based off-Axis Integrated Cavity Output Spectroscopy. Opt. Express. 2011, 19, 24078–24089. doi:https://doi.org/10.1364/OE.19.024078
- Hanf, S.; Keiner, R.; Yan, D.; Popp, Jr.; Frosch, T. Fiber-Enhanced Raman Multigas Spectroscopy: A Versatile Tool for Environmental Gas Sensing and Breath Analysis. Anal. Chem. 2014, 86, 5278–5285. doi:https://doi.org/10.1021/ac404162w
- Hanf, S.; Bögözi, T.; Keiner, R.; Frosch, T.; Popp, J. Fast and Highly Sensitive Fiber-Enhanced Raman Spectroscopic Monitoring of Molecular H2 and CH4 for Point-of-Care Diagnosis of Malabsorption Disorders in Exhaled Human Breath. Anal. Chem. 2015, 87, 982–988. doi:https://doi.org/10.1021/ac503450y
- Lauridsen, R. K.; Rindzevicius, T.; Molin, S.; Johansen, H. K.; Berg, R. W.; Alstrøm, T. S.; Almdal, K.; Larsen, F.; Schmidt, M. S.; Boisen, A. Towards Quantitative SERS Detection of Hydrogen Cyanide at Ppb Level for Human Breath Analysis. Sens. Bio-Sens. Res. 2015, 5, 84–89. doi:https://doi.org/10.1016/j.sbsr.2015.07.002
- Phillips, M.; Altorki, N.; Austin, J. H. M.; Cameron, R. B.; Cataneo, R. N.; Kloss, R.; Maxfield, R. A.; Munawar, M. I.; Pass, H. I.; Rashid, A.; et al. Detection of Lung Cancer Using Weighted Digital Analysis of Breath biomarkers. Clin. Chim. Acta. 2008, 393, 76–84.,doi:https://doi.org/10.1016/j.cca.2008.02.021
- Bajtarevic, A.; Ager, C.; Pienz, M.; Klieber, M.; Schwarz, K.; Ligor, M.; Ligor, T.; Filipiak, W.; Denz, H.; Fiegl, M.; et al. Noninvasive Detection of Lung Cancer by Analysis of Exhaled Breath. BMC Cancer 2009, 9, 348., doi:https://doi.org/10.1186/1471-2407-9-348
- Chen, X.; Xu, F.; Wang, Y.; Pan, Y.; Lu, D.; Wang, P.; Ying, K.; Chen, E.; Zhang, W. A Study of the Volatile Organic Compounds Exhaled by Lung Cancer Cells in Vitro for Breath Diagnosis. Cancer 2007, 110, 835–844. doi:https://doi.org/10.1002/cncr.22844
- Fuchs, P.; Loeseken, C.; Schubert, J. K.; Miekisch, W. Breath Gas Aldehydes as Biomarkers of Lung Cancer. Int. J. Cancer. 2010, 126, 2663–2670. doi:https://doi.org/10.1002/ijc.24970
- Phillips, M.; Cataneo, R. N.; Cummin, A. R.; Gagliardi, A. J.; Gleeson, K.; Greenberg, J.; Maxfield, R. A.; Rom, W. N. Detection of Lung Cancer with Volatile Markers in the Breath. Chest 2003, 123, 2115–2123. doi:https://doi.org/10.1378/chest.123.6.2115
- Machado, R. F.; Laskowski, D.; Deffenderfer, O.; Burch, T.; Zheng, S.; Mazzone, P. J.; Mekhail, T.; Jennings, C.; Stoller, J. K.; Pyle, J.; et al. Detection of Lung Cancer by Sensor Array Analyses of Exhaled Breath. Am. J. Respir. Crit. Care Med. 2005, 171, 1286–1291.,doi:https://doi.org/10.1164/rccm.200409-1184OC
- Wang, Y.; Hu, Y.; Wang, D.; Yu, K.; Wang, L.; Zou, Y.; Zhao, C.; Zhang, X.; Wang, P.; Ying, K. The Analysis of Volatile Organic Compounds Biomarkers for Lung Cancer in Exhaled Breath, Tissues and Cell Lines. CBM 2012, 11, 129–137. doi:https://doi.org/10.3233/CBM-2012-00270
- Rudnicka, J.; Kowalkowski, T.; Ligor, T.; Buszewski, B. Determination of Volatile Organic Compounds as Biomarkers of Lung Cancer by SPME-GC-TOF/MS and chemometrics . J. Chromatogr. B Analyt. Technol. Biomed. Life Sci. 2011, 879, 3360–3366. DOI: https://doi.org/10.1016/j.jchromb.2011.09.001.
- Caldeira, M.; Perestrelo, R.; Barros, A. S.; Bilelo, M.; Morete, A.; Câmara, JdS.; Rocha, S. M. Allergic Asthma Exhaled Breath Metabolome: A Challenge for Comprehensive Two-Dimensional Gas Chromatography. J. Chromatogr. A. 2012, 1254, 87–97. doi:https://doi.org/10.1016/j.chroma.2012.07.023.
- Dallinga, J.; Robroeks, C.; Van Berkel, J.; Moonen, E.; Godschalk, R.; Jöbsis, Q.; Dompeling, E.; Wouters, E.; Van Schooten, F. Volatile Organic Compounds in Exhaled Breath as a Diagnostic Tool for Asthma in Children. Clin. Exp. Allergy 2010, 40, 68–76. DOI: https://doi.org/10.1111/j.1365-2222.2009.03343.x.
- Phillips, M.; Cataneo, R. N.; Ditkoff, B. A.; Fisher, P.; Greenberg, J.; Gunawardena, R.; Kwon, C. S.; Tietje, O.; Wong, C. Prediction of Breast Cancer Using Volatile Biomarkers in the Breath. Breast Cancer Res. Treat. 2006, 99, 19–21. DOI: https://doi.org/10.1007/s10549-006-9176-1.
- Phillips, M.; Cataneo, R. N.; Saunders, C.; Hope, P.; Schmitt, P.; Wai, J. Volatile Biomarkers in the Breath of Women with Breast Cancer. J. Breath Res. 2010, 4, 026003 doi: https://doi.org/10.1088/1752-7155/4/2/026003.
- Phillips, M.; Cataneo, R. N.; Condos, R.; Erickson, G. A. R.; Greenberg, J.; Bombardi, V. L.; Munawar, M. I.; Tietje, O. Volatile Biomarkers of Pulmonary Tuberculosis in the Breath. Tuberculosis 2007, 87, 44–52. doi:https://doi.org/10.1016/j.tube.2006.03.004
- Phillips, M.; Basa-Dalay, V.; Bothamley, G.; Cataneo, R. N.; Lam, P. K.; Natividad, M. P. R.; Schmitt, P.; Wai, J. Breath Biomarkers of Active Pulmonary Tuberculosis. Tuberculosis (Edinb) 2010, 90, 145–151. DOI: https://doi.org/10.1016/j.tube.2010.01.003.
- Phillips, M.; Basa-Dalay, V.; Blais, J.; Bothamley, G.; Chaturvedi, A.; Modi, K. D.; Pandya, M.; Natividad, M. P. R.; Patel, U.; Ramraje, N. N.; et al. Point-of-Care Breath Test for Biomarkers of Active Pulmonary Tuberculosis. Tuberculosis (Edinb) 2012, 92, 314–320., DOI: https://doi.org/10.1016/j.tube.2012.04.002.
- Kolk, A.; Van Berkel, J.; Claassens, M.; Walters, E.; Kuijper, S.; Dallinga, J.; Van Schooten, F. Breath Analysis as a Potential Diagnostic Tool for Tuberculosis. Int. J. Tuberc. Lung Dis. 2012, 16, 777–782. DOI: https://doi.org/10.5588/ijtld.11.0576.
- Phillips, M.; Sabas, M.; Greenberg, J. Increased Pentane and Carbon Disulfide in the Breath of Patients with Schizophrenia. J. Clin. Pathol. 1993, 46, 861–864. DOI: https://doi.org/10.1136/jcp.47.9.870-e.
- Galassetti, P. R.; Novak, B.; Nemet, D.; Rose-Gottron, C.; Cooper, D. M.; Meinardi, S.; Newcomb, R.; Zaldivar, F.; Blake, D. R. Breath Ethanol and Acetone as Indicators of Serum Glucose Levels: An Initial Report. Diabetes Technol. Ther. 2005, 7, 115–123. DOI: https://doi.org/10.1089/dia.2005.7.115.
- Gaspar, E. M.; Lucena, A. F.; da Costa, J. D.; das Neves, H. C. Organic Metabolites in Exhaled Human Breath-a Multivariate Approach for Identification of Biomarkers in Lung Disorders. J. Chromatogr. A. 2009, 1216, 2749–2756. DOI: https://doi.org/10.1016/j.chroma.2008.10.125.
- Kumar, S.; Huang, J.; Abbassi-Ghadi, N.; Španěl, P.; Smith, D.; Hanna, G. B. Selected Ion Flow Tube Mass Spectrometry Analysis of Exhaled Breath for Volatile Organic Compound Profiling of Esophago-Gastric Cancer. Anal. Chem. 2013, 85, 6121–6128. DOI: https://doi.org/10.1021/ac4010309.
- Dryahina, K.; Španěl, P.; Pospíšilová, V.; Sovová, K.; Hrdlička, L.; Machková, N.; Lukáš, M.; Smith, D. Quantification of Pentane in Exhaled Breath, a Potential Biomarker of Bowel Disease, Using Selected Ion Flow Tube Mass Spectrometry. Rapid Commun. Mass Spectrom. 2013, 27, 1983–1992. DOI: https://doi.org/10.1002/rcm.6660.
- Endre, Z. H.; Pickering, J. W.; Storer, M. K.; Hu, W.-P.; Moorhead, K. T.; Allardyce, R.; McGregor, D. O.; Scotter, J. M. Breath Ammonia and Trimethylamine Allow Real-Time Monitoring of Haemodialysis Efficacy. Physiol. Meas. 2011, 32, 115–130. DOI: https://doi.org/10.1088/0967-3334/32/1/008.
- Dent, A. G.; Sutedja, T. G.; Zimmerman, P. V. Exhaled Breath Analysis for Lung Cancer. J. Thorac. Dis. 2013, 5, S540. doi:https://doi.org/10.3978/j.issn.2072-1439.2013.08.44
- Phillips, M.; Bauer, T. L.; Cataneo, R. N.; Lebauer, C.; Mundada, M.; Pass, H. I.; Ramakrishna, N.; Rom, W. N.; Vallières, E. Blinded Validation of Breath Biomarkers of Lung Cancer, a Potential Ancillary to Chest CT Screening. PLoS One. 2015, 10, e0142484. doi:https://doi.org/10.1371/journal.pone.0142484
- Campbell, J. L.; Le Blanc, J. Y.; Kibbey, R. G. Differential Mobility Spectrometry: A Valuable Technology for Analyzing Challenging Biological Samples. Bioanalysis 2015, 7, 853–856. DOI: https://doi.org/10.4155/bio.15.14.
- Li, C.; Wang, G. The Research on Artificial Olfaction System-Electronic Nose. J. Phys: Conf. Ser. 2006, 48, 667–670. IOP Publishing, doi:https://doi.org/10.1088/1742-6596/48/1/125
- Oh, E. H.; Song, H. S.; Park, T. H. Recent Advances in Electronic and Bioelectronic Noses and Their Biomedical Applications. Enzyme Microb. Technol. 2011, 48, 427–437. doi:https://doi.org/10.1016/j.enzmictec.2011.04.003
- Shan, B.; Broza, Y. Y.; Li, W.; Wang, Y.; Wu, S.; Liu, Z.; Wang, J.; Gui, S.; Wang, L.; Zhang, Z.; et al. Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath. ACS Nano. 2020, 14, 12125–12132. doi:https://doi.org/10.1021/acsnano.0c05657
- Röck, F.; Barsan, N.; Weimar, U. Electronic Nose: current Status and Future Trends. Chem. Rev. 2008, 108, 705–725. doi:https://doi.org/10.1021/cr068121q
- Fine, G. F.; Cavanagh, L. M.; Afonja, A.; Binions, R. Metal Oxide Semi-Conductor Gas Sensors in Environmental Monitoring. Sensors (Basel) 2010, 10, 5469–5502. doi:https://doi.org/10.3390/s100605469
- Righettoni, M.; Amann, A.; Pratsinis, S. E. Breath Analysis by Nanostructured Metal Oxides as Chemo-Resistive Gas Sensors. Mater. Today 2015, 18, 163–171. doi:https://doi.org/10.1016/j.mattod.2014.08.017
- Rogers, P. H.; Benkstein, K. D.; Semancik, S. Machine Learning Applied to Chemical Analysis: Sensing Multiple Biomarkers in Simulated Breath Using a Temperature-Pulsed Electronic-Nose. Anal. Chem. 2012, 84, 9774–9781. doi:https://doi.org/10.1021/ac301687j
- Righettoni, M.; Tricoli, A. Toward Portable Breath Acetone Analysis for Diabetes Detection. J. Breath Res. 2011, 5, 037109 doi:https://doi.org/10.1088/1752-7155/5/3/037109
- Neri, G.; Bonavita, A.; Micali, G.; Donato, N. Design and Development of a Breath Acetone MOS Sensor for Ketogenic Diets Control. IEEE Sensors J. 2010, 10, 131–136. doi:https://doi.org/10.1109/JSEN.2009.2035663
- Gouma, P.; Kalyanasundaram, K.; Yun, X.; Stanacevic, M.; Wang, L. Nanosensor and Breath Analyzer for Ammonia Detection in Exhaled Human Breath. IEEE Sensors J. 2010, 10, 49–53. doi:https://doi.org/10.1109/JSEN.2009.2036050
- Dan, Y.; Cao, Y.; Mallouk, T. E.; Johnson, A. T.; Evoy, S. Dielectrophoretically Assembled Polymer Nanowires for Gas Sensing. Sens. Actuat. B: Chem. 2007, 125, 55–59. doi:https://doi.org/10.1016/j.snb.2007.01.042
- Yu, J.-B.; Byun, H.-G.; So, M.-S.; Huh, J.-S. Analysis of Diabetic Patient's Breath with Conducting Polymer Sensor Array. Sens. Actuat. B: Chem. 2005, 108, 305–308. doi:https://doi.org/10.1016/j.snb.2005.01.040
- Chatterjee, S.; Castro, M.; Feller, J.-F. An E-nose Made of Carbon Nanotube Based Quantum Resistive Sensors for the Detection of Eighteen Polar/Nonpolar VOC Biomarkers of Lung Cancer. J. Mater. Chem. B. 2013, 1, 4563–4575. DOI: https://doi.org/10.1039/C3TB20819B.
- Liu, C.; Hayashi, K.; Toko, K. Au Nanoparticles Decorated Polyaniline Nanofiber Sensor for Detecting Volatile Sulfur Compounds in Expired Breath. Sens. Actuat. B Chem. 2012, 161, 504–509. doi:https://doi.org/10.1016/j.snb.2011.10.068
- Ding, B.; Kim, J.; Miyazaki, Y.; Shiratori, S. Electrospun Nanofibrous Membranes Coated Quartz Crystal Microbalance as Gas Sensor for NH3 Detection. Sens. Actuat. B Chem. 2004, 101, 373–380. doi:https://doi.org/10.1016/j.snb.2004.04.008
- Lu, H.-H.; Rao, Y. K.; Wu, T.-Z.; Tzeng, Y.-M. Direct Characterization and Quantification of Volatile Organic Compounds by Piezoelectric Module Chips Sensor. Sens. Actuat. B: Chem. 2009, 137, 741–746. doi:https://doi.org/10.1016/j.snb.2009.01.060
- Andreeva, N.; Ishizaki, T.; Baroch, P.; Saito, N. High Sensitive Detection of Volatile Organic Compounds Using Superhydrophobic Quartz Crystal Microbalance. Sens. Actuat. B: Chem. 2012, 164, 15–21. doi:https://doi.org/10.1016/j.snb.2012.01.051
- Buszewski, B.; Grzywinski, D.; Ligor, T.; Stacewicz, T.; Bielecki, Z.; Wojtas, J. Detection of Volatile Organic Compounds as Biomarkers in Breath Analysis by Different Analytical Techniques. Bioanalysis 2013, 5, 2287–2306. doi:https://doi.org/10.4155/bio.13.183
- Righettoni, M.; Tricoli, A.; Pratsinis, S. E. Si: WO3 Sensors for Highly Selective Detection of Acetone for Easy Diagnosis of Diabetes by Breath Analysis. Anal. Chem. 2010, 82, 3581–3587. doi:https://doi.org/10.1021/ac902695n
- Konvalina, G.; Haick, H. Effect of Humidity on Nanoparticle-Based Chemiresistors: A Comparison between Synthetic and Real-World Samples. ACS Appl. Mater. Interfaces 2012, 4, 317–325. doi:https://doi.org/10.1021/am2013695
- Dragonieri, S.; Schot, R.; Mertens, B. J. A.; Le Cessie, S.; Gauw, S. A.; Spanevello, A.; Resta, O.; Willard, N. P.; Vink, T. J.; Rabe, K. F.; et al. An Electronic Nose in the Discrimination of Patients with Asthma and Controls. J. Allergy Clin. Immunol. 2007, 120, 856–862.,doi:https://doi.org/10.1016/j.jaci.2007.05.043
- Dragonieri, S.; van der Schee, M. P.; Massaro, T.; Schiavulli, N.; Brinkman, P.; Pinca, A.; Carratú, P.; Spanevello, A.; Resta, O.; Musti, M.; Sterk, P. J. An Electronic Nose Distinguishes Exhaled Breath of Patients with Malignant Pleural Mesothelioma from Controls. Lung Cancer 2012, 75, 326–331. doi:https://doi.org/10.1016/j.lungcan.2011.08.009
- Dragonieri, S.; Annema, J. T.; Schot, R.; van der Schee, M. P.; Spanevello, A.; Carratú, P.; Resta, O.; Rabe, K. F.; Sterk, P. J. An Electronic Nose in the Discrimination of Patients with Non-Small Cell Lung Cancer and COPD. Lung Cancer 2009, 64, 166–170. doi:https://doi.org/10.1016/j.lungcan.2008.08.008
- Cheng, Z.; Warwick, G.; Yates, D.; Thomas, P. An Electronic Nose in the Discrimination of Breath from Smokers and Non-Smokers: A Model for Toxin Exposure. J. Breath Res. 2009, 3, 036003 doi:https://doi.org/10.1088/1752-7155/3/3/036003
- Chapman, E. A.; Thomas, P. S.; Stone, E.; Lewis, C.; Yates, D. H. A Breath Test for Malignant Mesothelioma Using an Electronic Nose. Eur. Respir. J. 2012, erj00409–02011. doi:https://doi.org/10.1183/09031936.00040911
- Montuschi, P.; Santonico, M.; Mondino, C.; Pennazza, G.; Mantini, G.; Martinelli, E.; Capuano, R.; Ciabattoni, G.; Paolesse, R.; Di Natale, C.; et al. Diagnostic Performance of an Electronic Nose, Fractional Exhaled Nitric Oxide, and Lung Function Testing in Asthma. Chest 2010, 137, 790–796.,doi:https://doi.org/10.1378/chest.09-1836
- Fleischer, M.; Simon, E.; Rumpel, E.; Ulmer, H.; Harbeck, M.; Wandel, M.; Fietzek, C.; Weimar, U.; Meixner, H. Detection of Volatile Compounds Correlated to Human Diseases through Breath Analysis with Chemical Sensors. Sens. Actuat. B: Chem. 2002, 83, 245–249. doi:https://doi.org/10.1016/S0925-4005(01)01056-5
- Xu, Y.; Lee, H.; Hu, Y.; Huang, J.; Kim, S.; Yun, M. Detection and Identification of Breast Cancer Volatile Organic Compounds Biomarkers Using Highly-Sensitive Single Nanowire Array on a Chip. J. Biomed. Nanotechnol. 2013, 9, 1164–1172. doi:https://doi.org/10.1166/jbn.2013.1651
- Unnikrishnan, V. K.; Choudhari, K. S.; Kulkarni, S. D.; Nayak, R.; Kartha, V. B.; Santhosh, C. Analytical Predictive Capabilities of Laser Induced Breakdown Spectroscopy (LIBS) with Principal Component Analysis (PCA) for Plastic Classification. RSC Adv. 2013, 3, 25872–25880. doi:https://doi.org/10.1039/c3ra44946g
- Venkatakrishna, K.; Kurien, J.; Pai, K. M.; Valiathan, M.; Kumar, N. N.; Krishna, C. M.; Ullas, G.; Kartha, V. B. Optical Pathology of Oral Tissue: A Raman Spectroscopy Diagnostic Method. Curr. Sci. 2001, 80, 665–668.
- Rai, L.; Krishnanand, B.; Mahato, K. K.; Kartha, V. B.; Santhosh, C. Protein Profile Study of the Cervical Cancer Using HPLC-LIF, in: Ultrasensitive and Single-Molecule Detection Technologies. Int. Soc. Opt. Photonics. 2006, 6092, 60920. doi:https://doi.org/10.1117/12.647292
- Bhat, S.; Patil, A.; Rai, L.; Kartha, V. B.; Santhosh, C. Protein Profile Analysis of Cellular Samples from the Cervix for the Objective Diagnosis of Cervical Cancer Using HPLC-LIF. J. Chromatogr. B: Analyt Technol. Biomed. Life Sci. 2010, 878, 3225–3230. doi:https://doi.org/10.1016/j.jchromb.2010.09.025
- Bhat, S.; Patil, A.; Rai, L.; Kartha, V. B.; Chidangil, S. Application of HPLC Combined with Laser Induced Fluorescence for Protein Profile Analysis of Tissue Homogenates in Cervical Cancer. Sci. World J. 2012, 2012, 1–7. doi:https://doi.org/10.1100/2012/976421
- Raja, S. N.; Rai, L.; Kumar, P.; Mahato, K. K.; Kartha, V. B.; Chidangil, S. Serum Protein Profile Study of Normal and Cervical Cancer Subjects by High Performance Liquid Chromatography with Laser-Induced Fluorescence. J. Biomed. Opt. 2008, 13, 054062. doi:https://doi.org/10.1117/1.2992166
- Patil, A.; Prabhu, V.; Choudhari, K. S.; Unnikrishnan, V. K.; George, S. D.; Ongole, R.; Pai, K. M.; Shetty, J. K.; Bhat, S.; Kartha, V. B.; Chidangil, S. Evaluation of High-Performance Liquid Chromatography Laser-Induced Fluorescence for Serum Protein Profiling for Early Diagnosis of Oral Cancer. J. Biomed. Opt. 2010, 15, 067007 doi:https://doi.org/10.1117/1.3523372
- Vidyasagar, M.; Maheedhar, K.; Vadhiraja, B.; Fernendes, D. J.; Kartha, V.; Krishna, C. M. Prediction of Radiotherapy Response in Cervix Cancer by Raman Spectroscopy: A Pilot Study. Biopolymers: Original Res. Biomolecules 2008, 89, 530–537. doi:https://doi.org/10.1002/bip.20923
- Chan, D.; Booth, R.; Diamandis, E. Tumor Markers in Text Book of Clinical Chemistry; Teitz Text Book of Clinical Chemistry Elsevier: Amsterdam, Netherlands, 2008.