References
- Jin KN, Park CM, Goo JM, et al. Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol 2010; 20(9):2108–2115.
- Manhire A, Charig M, Clelland C, et al. Guidelines for radiologically guided lung biopsy. Thorax 2003; 58(11):920–936.
- Geraghty PR, Kee ST, McFarlane G, et al. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 2003; 229(2):475–481.
- Hiraki T, Mimura H, Gobara H, et al. CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 2009; 136(6):1612–1617.
- Hoheisel M, Skalej M, Beuing O, et al. Kyphoplasty interventions using a navigation system and C-arm CT data: first clinical results. In: Medical Imaging 2009: Physics of Medical Imaging, edited by Ehsan Samei, Jiang Hsieh, Proc. of SPIE Vol. 7258, 72580E . 2009 SPIE CCC code: 1605-7422/09/$18. doi:10.1117/12.811600
- Bruners P, Penzkofer T, Nagel M, et al. Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results. Eur Radiol 2009; 19(4):990–994.
- Meier-Meitinger M, Nagel M, Kalender W, Bautz WA, et al. Computer-assisted navigation system for interventional CT-guided procedures: results of phantom and clinical studies. Rofo 2008; 180(4):310–317
- Wallace MJ, Gupta S, Hicks ME. Out-of-plane computed tomography-guided biopsy using a magnetic-field-based navigation system. Cardiovasc Intervent Radiol 2009; 29(1):108–113
- Grand DJ, Atalay MA, Cronan JJ, et al. CT-guided percutaneous lung biopsy: comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients. Eur J Radiol 2011; 79(2):e133–e136.
- Lee SM, Park CM, Lee KH, et al. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology 2014; 271(1):291–300.
- Hwang HS, Chung MJ, Lee JW, et al. C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules. AJR Am J Roentgenol 2010; 195(6):W400–407.
- Choi JW, Park CM, Goo JM, et al. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤ 20mm) lung nodules: diagnostic accuracy and complications in 161 patients. AJR Am J Roentgenol 2012; 199(3):W322–330.
- Choi MJ, Kim Y, Hong YS, et al. Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety. Br J Radiol 2012; 85(1014):e182–187.
- Lee WJ, Chong S, Seo JS, et al. Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and post-procedural complications. Br J Radiol. 2012; 85(1014):e217–222.
- Choo JY, Park CM, Lee NK, et al. Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance. Eur Radiol. 2013; 23(3):712–719.
- Braak SJ, Herder GJ, van Heesewijk JP, et al. Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol. 2012; 35(6):1414–1421.
- Jiao de C, Li TF, Han XW, et al. Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions. Diagn Interv Radiol. 2014; 20(6):470–474.
- Grasso RF, Faiella E, Luppi G, et al. Percutaneous lung biopsy: comparison between an augmented reality CT navigation system and standard CT-guided technique. Int J Comput Assist Radiol Surg. 2013; 8(5):837–848.
- Grasso RF, Luppi G, Cazzato RL, et al. Percutaneous computed tomography-guided lung biopsies: preliminary results using an augmented reality navigation system. Tumori 2012; 98(6):775–782.
- Grasso RF, Cazzato RL, Luppi G, et al. Percutaneous lung biopsies: performance of an optical CT-based navigation system with a low-dose protocol. Eur Radiol. 2013; 23(11):3071–3076.