References
- American Conference of Governmental Industrial Hygienists . Industrial Ventilation—A Manual of Recommended Practice 19th ed. Cincinnati, OH : ACGIH .
- Tyaglo , I. G. and Shepelev , I. A. 1970 . Dvizhenie vozdushnogo potoha k vytyazhnomu otversityu (Air Flow Near an Exhaust Opening) (in Russian) . Vodosnabzhenie i sanitarnaya teknika , 5 : 24
- Conroy , L. M. , Ellenbecker , M. J. and Flynn , M. R. 1988 . Prediction and Measurement of Velocity into Flanged Slot Hoods . Am. Ind. Hyg. Assoc. J. , 49 ( 5 ) : 226
- Esmen , N. A. , Weyel , D. A. and McGuigan , F. P. 1986 . Aerodynamic Properties of Exhaust Hoods . Am. Ind. Hyg. Assoc. J. , 47 ( 8 ) : 448
- Flynn , M. R. and Ellenbecker , M. J. 1985 . The Potential Flow Solution for Air Flow into a Flanged Circular Hood . Am. Ind. Hyg. Assoc. J. , 46 ( 6 ) : 318
- Flynn , M. R. and Ellenbecker , M. J. 1987 . Empirical Validation of Theoretical Velocity Fields into Flanged Circular Hoods . Am. Ind. Hyg. Assoc. J. , 48 ( 4 ) : 380
- Drakal , F. 1970 . Stromungsverhaltnisse bei runden Saugoffnungen mit Flansch, (Flow Conditions for Round Suction Openings with a Flange) . Heiz. Luft. Klim , 21 : 271
- Flynn , M. R. and Miller , C. T. 1989 . The Boundary Integral Equation Method (BIEM) for Modeling Local Exhaust Hood Flow Fields . Am. Ind. Hyg. Assoc. J. , 50 ( 5 ) : 281
- Braconnier , R. 1988 . Bibliographic Review of Velocity Fields in the Vicinity of Local Exhaust Hood Openings . Am. Ind. Hyg. Assoc. J. , 49 ( 4 ) : 185
- Wilkinson , L. 1986 . SYSTAT: The System for Statistics , Evanston, IL : SYSTAT Inc. .