- Anderson JM, Miller KM. Biomaterial biocompatability and the macrophage. Biomaterials 1984;5:5–10.
- Coleman DL, King RN, and Andrade JD. The foreign body reaction: a chronic inflammatory response. J Biomed Mater Resources 1974;8:191–211.
- Benghuzzi H, Bajpai P. Long-term delivery of testosterone by ALCAP ceramic implants in rats. J App Biomater. 1990;1:233–240.
- Benghuzzi H, England B, Bajpai P, Griffn B. Successful an- tidote of multiple lethal infections using sustained delivery of difluoromethylornithine by means of ceramic drug de- livery devices. Clin Mater. 1994;15:151 –160.
- Benghuzzi H, England B, Bajpai P. Physical properties and potential behavior of TCPAA devices in vitro. Proceed- ings of the Thirteenth Southern Biomedical Engineering Conference, April 16–17, Washington, DC, 1994:474– 477.
- Benghuzzi H, Bajpai P, England B. Pathophysiological eval- uation associated with sustained delivery of danazol and dihydrotestosterone in adult male rodents. Biomed Sci In- strum. 1994;94:197–204.
- Benghuzzi H, England B. The effect of highly com- pressed TCPL mixed particle sizes on the delivery rate of steroid hormones. Proceedings of the Thirteenth South- ern Biomedical Engineering Conference. April 16–17, Washington DC, 1994:486–489.
- Benghuzzi HA, Bajpai PK. Sustained release of steroid hormones from polyactic acid or polycaprolactone- impregnated. CRC Hand Bioactive Ceram. 1988;2:93– 108.
- Coleman DL, King RN, Andrade JD. The foreign body reaction-an experimental protocol. J Biomed Mater Re- sources. 1974;5:65–76.
- Anderson JM. The extracellular matrix and biomaterials. In: Greco RS, ed. Implantation Biology—The Host Re- sponse to Biomedical Devices. Boca Raton, FL: CRC Press; 1994:113–130.
- Tang L, Eaton JW. Fibrin(ogen) mediates acute in- flammatory responses to biomaterials. J Exp Med. 1993;178:2147 –2156.
- Bouet T, Toyoda K, Ikarashi K, Uchima T, Nakamur a A, Tsuchiya T, Takahashi M, Elroy R. Evaluation of biocom- patibility, based on quantitative determination of the vas- cular response induced by material implantation. J Biomed Mater Resources. 1991;25:1507–1521.
- Tang L, Eaton JW. Inflammatory response to biomaterials. Am J Clin Pathol. 1995;103:466–471.
- Benghuzzi HA, England BG, Baipai PK. Controlled release of hydrophilic compounds by resorbable and biodegrad- able ceramic drug delivery devices. Biomed Sci Instrum. 1992;28:179–182.
- Anderson JM. The biocompatibility of human im- plants. Fundam Aspects Biocompat. 1981;C11:205– 217.
- Archer RS, Downes S. A histological and ultrastructural assessment of the tissue response to calcium phosphate ceramics. In: Bonfeld W, Hastings GW, Tanner KE, eds. Bioceramics, vol. 4. London: Butterworth-Heinemann; 1991:179–186.
- Bajpai PK, Benghuzzi HA. Ceramic systems for long term delivery of chemicals and biologicals. J Biomed Mater Re- sources. 1988;22:1245 –1266.
- Benghuzzi H, Bajpai P, England B. The delivery of testos- terone and dihydrotestosterone by ALCAP ceramic im- plants in rats. J Invest Surg. 1990;3:197–215.
- Benghuzzi H, Possley R, England B. The use of tricalcium- phosphate-lysine implants to deliver estrogen in a sustained level for one year in adult castrated rams. Pro- ceedings of the Thirteenth Southern Biomedical Engineer- ing Conference, April 16–17, Washington DC, 1994:79– 81.
- Benghuzzi H, Possley R, England B. Pulsatile delivery of progesterone and estradiol to mimic the ovulatory surge in adults ewes by means of TCPL implants. Biomed Sci Instrum. 1994;94:187–189.
- Benghuzzi HA, England BG, Bajpai PK. Characteristics of ceramic drug delivery devices: The effect of various temperature of incubation on the delivery of biologicals. Biomed Sci Instrum. 1992;28:129 –134.
- Benghuzzi HA, England BG, Bajpai PK. In vivo delivery of estradiol from ceramic drug delivery devices. Biomed Sci Instrum. 1991;27:181–187.
- Benghuzzi HA, Barbaro RM, Bajpai PK. In vitro re- lease of azidothymidine (AZT) by ceramic drug de- livery systems. Biomed Sci Instrum. 1990;26:151– 156.
- Ushida T, Tateishi T, Yanagisawa S. Evaluation of cell mor- phology on bioceramics. Bioceramics, Proc 1st Int Bioce- ramic Symp. 1989:36–101.
- Donath K. Tissue reaction to Ca-phosphate ceramics. In: Hironobu O, Hideki A, Kazuhiko S, eds. Bioceramics. Tokyo. Ishiyaku EuroAmerica; 1989:96–101.
- Salthouse TN. Some aspects of macrophage behavior at the implant interface. J Biomed Mater Resources. 1984;18:395 –401.
- Tang L, Ugarova T, Plow E, Eaton J. Molecular determi- nants of acute inflammatory responses to biomaterials. J Clin Invest. 1996;97(5):1329 –1344.
- Guo W, Willen R, Anderson R, Parsson H, Liu X, Johans- son K, Bengmark S. Morphological response of the peritoneum and spleen to intraperitoneal biomaterials. Int J Artif Organs. 1993;16(5):276 –284.
- Meachim G, Pedley RB. The tissue response at implant sites. In: Williams DF, ed. Fundamental Aspects of Bio- compatibility, vol. 1. Boca Raton, FL: CRC Press; 1993: 108–147.
- Meachim G. Histologic interpretations of tissue changes adjacent to orthopaedic implants. In: Williams DF, ed. Biocompatibility of Implant Materials. London: Sector; 1976:120–127.
- Williams DF. Toxicology of ceramics. Fundam Aspects Biocompat. 1981;C4:87–93.
- Williams DF. Fundamental aspects of biocompatibility. Boca Raton, FL. CRC Press; 1981:1,8–12.