Assessment of the Thrombogenic Effect of Fibrin Sealant Dressing in a Vascular Surgery Model in Rabbits

, PhD, , BS & , MD
Pages 387-396 | Received 30 Jan 2006, Accepted 23 Jul 2006, Published online: 09 Jul 2009

REFERENCES

  • Spangler H P, Braun F, Holle T, et al. The local application of fibrinogen and collagen for hemostasis in heart surgery. Wien Med Wochenschr 1976; 126: 86, [INFOTRIEVE], [CSA]
  • Codispoti M, Mankad P S. Significant merits of a fibrin sealant in the presence of coagulopathy following pediatric cardiac surgery: Randomized controlled trail. Eur J 3 Cardiothorac Surg 2002; 22: 200–205, [CSA], [CROSSREF]
  • Milne A A, Murphy W G, Reading S J, Ruckley C V. A randomized trail of fibrin sealant in peripheral vascular surgery. Vox Sang 1996; 70: 210–212, [INFOTRIEVE], [CSA]
  • Rousou J, Levitsky S, Gonzalez-Lavin L, et al. Randomized clinical trail of fibrin sealant in patients undergoing resternotomy or reoperation after cardiac operations: A multicenter study. J Thorac Cardiovasc Surg 1989; 97: 194–203, [INFOTRIEVE], [CSA]
  • Kram H B, Garces M A, Klein S R, Shoemaker W C. Common bile duct anastomosis using fibrin glue. Arch Surg 1985; 120: 1250–1256, [INFOTRIEVE], [CSA]
  • Noun R, Elias D, Balladur P, Bismuth H, Parc R, Lasser P, Belghiti J. Fibrin glue effectiveness and tolerance after elective liver resection: A randomized trail. Hepatogastroenterology 1996; 43: 221–224, [INFOTRIEVE], [CSA]
  • Davidson B R, Burnett S, Javed M S, Seifalian A, Moore D, Doctor N. Experimental study of a novel fibrin sealant for achieving haemostasis following partial hepatectomy. Br J Surg 2000; 87: 790–795, [INFOTRIEVE], [CSA], [CROSSREF]
  • Matthew T L, Spotnitz W D, Kron I L, Daniel T M, Tribble C G, Nolan S P. Four years' experience with fibrin sealant in thoracic and cardiovascular surgery. Ann Thorac Surg 1990; 50: 40–43, [INFOTRIEVE], [CSA]
  • Kjaergard H K, Trumbull H R. Vivostat system autologous fibrin sealant: Preliminary study in elective coronary bypass grafting. Ann Thorac Surg 1998; 66: 482–486, [INFOTRIEVE], [CSA], [CROSSREF]
  • Marek C A, Amiss L R, Morgan R F, Spotnitz W D, Drake D B. Acute thrombogenic effects of fibrin sealant on microvascular anastomoses in a rat model. Ann Plast Surg 1998; 41: 415–419, [INFOTRIEVE], [CSA], [CROSSREF]
  • Heil B, Hong C, Connolly K, et al. Thrombin from fibrin glue diffuses into lumen and enhances thrombogenicity of human arteries. Am Soc Reconstr Microsurg Meeting. 1995, (abstr)
  • Northup C J, Wax M K, Clovis N B. The effects of fibrin glue on fasciocutaneous free flaps in a rat model. Soc Microsurg Spec Meeting. 1996, (abstr)
  • Frost-Arner L, Spotnitz W D, Rodeheaver G T, Drake D B. Comparison of the thrombogenicity of internationally available fibrin sealants in an established microsurgical model. Plast Recostr Surg 2001; 108: 1655–1660, [CSA], [CROSSREF]
  • Larson M J, Bowersox J C, Lim R C, Hess J R. Efficacy of a fibrin hemostatic bandage in controlling hemorrhage from experimental arterial injuries. Arch Surg 1995; 130: 420–422, [INFOTRIEVE], [CSA]
  • Holcomb J B, MacPhee M, Hetz S P, et al. Efficacy of a dry fibrin sealant dressing for hemorrhage control after ballistic injury. Arch Surg 1998; 133: 32–35, [INFOTRIEVE], [CSA], [CROSSREF]
  • Holcomb J B, Pusateri A E, Harris R A, et al. Effect of dry fibrin sealant dressings versus gauze packing on blood loss in grade V liver injuries in resuscitated swine. J Trauma 1999; 46: 49–57, [INFOTRIEVE], [CSA]
  • Holcomb J B, Pusateri A E, Harris R A, Reid T J, Beall L D, Hess J R, MacPhee M J. Dry fibrin sealant dressings reduce blood loss, resuscitation volume, and improve survival in hypothermic coagulopathic swine with grade V liver injuries. J Trauma 1999; 47: 233–242, [INFOTRIEVE], [CSA]
  • Cornum R, Bell J, Gresham V, Brinkley W, Beall D, MacPhee M. Intraoperative use of the absorbable fibrin adhesive bandage: Long term effects. J Urol 1999; 162: 1817–1820, [INFOTRIEVE], [CSA], [CROSSREF]
  • Cornum R L, Mares A F, Harris R A, et al. Does the absorbable fibrin adhesive bandage facilitate partial nephrectomy?. J Urol 2000; 164: 864–867, [INFOTRIEVE], [CSA], [CROSSREF]
  • Morey A F, Anema J G, Harris R, et al. Treatment of grade 4 renal stab wounds with absorbable fibrin adhesive bandage in a porcine model. J Urol 2001; 165: 955–958, [INFOTRIEVE], [CSA], [CROSSREF]
  • Bishoff J T, Cornum R L, Perahia B, et al. Laparoscopic heminephrectomy using a new fibrin sealant powder. Urology 2003; 62: 1139–1143, [INFOTRIEVE], [CSA], [CROSSREF]
  • Christenson T, Arvidsson D, Thorne J, Olsson P I, Norgren L, Strand S E. Comparison of two methods of labeling autologous platelets with in-111 oxine in five different species. Eur Nuc Med 1983; 8: 389–392, [CSA]
  • Hill-Zobel R, Gannon S, McCandless R, Tsan M. Effects of chelates and incubation media on platelet labeling with indium-111. J Nuc Med 1987; 28: 223–228, [CSA]
  • Softeland E, Hervig T, Framstad T, Holmsen H. Simple method for labeling of porcine platelets with In-111 oxine. Lab Anim Sci 1995; 45(2)195–198, [INFOTRIEVE], [CSA]
  • Davis H H, Heaton W A, Siegel B A, Mathias C J, Joist J H, Sherman L A, Welch M J. Scintigraphic detection of atherosclerotic lesions and venous thrombi in man by indium-111 labeled autologous platelets. Lancet 1978; I: 1185–1187, [CSA], [CROSSREF]
  • Institute of Laboratory Animal Resources, National Research Council. Guide for the Care and Use of Laboratory Animals. National Academy Press, Washington, DC 1996
  • Hanson S R, Griffin J H, Harker L A, et al. Antithrombotic effects of thrombin-induced activation of endogenous protein C in primates. Am J Clin Invest 1993; 92: 2003–2012, [CSA]
  • Kozma C, Macklin W, Cummins L M, Mauer R. Anatomy, physiology, and biochemistry of the rabbit. The Biology of the Laboratory Rabbit, S Weisbroth, R E Flatt, A L Kraus. Academic Press, New York 1974; 50–69
  • May G R, Herd C M, Butler K D, Page C P. Radioisotopic model for investigating thromboembolism in the rabbit. J Pharmacol Methods 1990; 24: 19–35, [INFOTRIEVE], [CSA], [CROSSREF]
  • Thiagarajan P, Benedict C R. Inhibition of arterial thrombosis by recombinant Annexin V in a rabbit carotid artery injury model. Circulation 1997; 96: 2339–2347, [INFOTRIEVE], [CSA]
  • Janicek M J, Van Den Abbeele A D, Hollenberg N K, et al. Platelet activation and aggregation after endothelial injury. Assessment with indium-111-labelled platelets and angiography. Invest Radio 1990; 25: 988–993, [CSA]
  • Thorne J, Olsson P I, Strand S E, et al. An experimental method for in vivo studies of pulmonary platelet sequestration. Eur J Nucl Med 1984; 9: 472–477, [INFOTRIEVE], [CSA], [CROSSREF]
  • Hill-Zobel R L, Scheffel U, Mclntyre P A, Tsan M. 111-In-oxine-labelled rabbit platelets: In vivo distribution and site of destruction. Blood 1983; 61: 149–153, [INFOTRIEVE], [CSA]
  • Wesley J R, Wesley R E. A study of the lethal effects of intravenous injection of thrombin on rabbits. Ann Ophthalmol 1990; 22: 457–459, [INFOTRIEVE], [CSA]
  • Isaka Y, Kimura K, Etani H, Uehara A, Uyama O, Yoneda S, Kamada T, Kusunoki M. Effect of aspirin and ticlopidine on platelet deposition in carotid atherosclerosis: Assessment by indium-111 platlet scintigraphy. Stroke 1986; 17: 1215–1220, [INFOTRIEVE], [CSA]
  • Powers W J, Siegel B A, Davis H H, Mathias C J, Clark H B, Welch M J. Indium-111 platelet scintigraphy in cerebrovascular disease. Neurology 1982; 32: 938–943, [INFOTRIEVE], [CSA]
  • Ritchie J L, Stratton J R, Thiele B, Hamilton G W, Warrick L N, Huang T W, Harker L A. Indium-111 platelet imaging for detection of platelet deposition in abdominal aneurysms and prosthetic arterial grafts. Am J Cardiol 1981; 47: 882–889, [INFOTRIEVE], [CSA], [CROSSREF]
  • Pusateri A E, Holcomb J B, Bhattacharyya S N, et al. Different hypotensive responses to intravenous bovine and human thrombin preparations in swine. J Trauma 2001; 50: 83–90, [INFOTRIEVE], [CSA]
  • Kheirabadi B S, Pearson R, Rudnicka K, Somwaru L, MacPhee M, Drohan W, Tuthill D. Development of an animal model for assessment of the hemostatic efficacy of fibrin sealant in vascular surgery. J Surg Res 2001; 100: 84–92, [INFOTRIEVE], [CSA], [CROSSREF]
  • Kheirabadi B S, Pearson R, Tuthill D, Rudnicka K, Holcomb J B, Drohan W, MacPhee M J. Comparative study of the hemostatic efficacy of a new human fibrin sealant: Is an antifibrinolytic agent necessary?. J Trauma 2002; 52: 1107–1115, [INFOTRIEVE], [CSA]
  • Zarge J I, Gosselin C, Huang P, Vorp D A, Severyn D A, Greisler H P. Platelet deposition on ePTFE grafts coated with fibrin glue with or without FGF-1 and heparin. J Surg Res 1997; 67: 4–8, [INFOTRIEVE], [CSA], [CROSSREF]

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.