127
Views
71
CrossRef citations to date
0
Altmetric
Research Article

Diamond-Like Carbon Coating and Plasma or Glow Discharge Treatment of Mechanical Heart Valves

Pages 133-140 | Published online: 09 Jul 2009

REFERENCES

  • Rahimtoola SH. Valvular heart disease: A perspective. J Am Coll Cardiol. 1983;1:199–215.
  • Cohn LH. The long-term results of aortic valve replace- ment. Chest. 1984;85:387–396.
  • Edmunds LH. Thrombotic and bleeding complications of prosthetic heart valves. Ann Thorac Surg. 1987;44:430- 445.
  • Schoen FJ. Surgical pathology of removed natural and prosthetic heart valves. Hum Pathol. 1987;18(6):558- 567.
  • Edmunds LH. Thrombotic complications of current cardiac valvular prostheses. Ann Thorac Surg. 1982;34:96–106.
  • Fernandez J, Laub GW, Adkins MS, et al. Early and late-phase events after valve replacement with the St. Jude Medical prosthesis in 1200 patients. J Thorac Cardiovasc Surg. 1994;107:394–407.
  • Akins CW. Results with mechanical cardiac valvular prostheses. Ann Thorac Surg. 1995;60:1836–1844.
  • Kuntze CEE, Blacksone EH, Ebels T. Thromboembolism and mechanical heart valves: A randomized study revisited. Ann Thorac Surg. 1988;66:101–107.
  • Schoen FJ. Cardiac valve prostheses: Review of clinical status and contemporary biomaterial issues. J Biomed Mater Res. 1987;21(A1):91–117.
  • Vongpatanasi n W, Hillis DL, Lange RA. Prosthetic heart valves. N Engl J Med. 1996;335(6):407–416.
  • Levine MN, Rakob G, Hirsch J. Risk of hemorrhage associated with long-term anticoagulant therapy. Drugs. 1985;30:444–460.
  • Turpie AG, Gent M, Laupacis A, Tatour Y, Gunstensen J, Basile F, et al. A comparison of aspirin with placebo in patients treated with warfarin after heart-valve replacement. N Engl J Med. 1993;329:524–529.
  • Dutton RC, Webber AJ, Johnson SA, Baier RE. Microstruc- ture of initial thrombus formation on foreign materials. Biomed Mater Res. 1969;3:13–23.
  • Silver MD, Wilson GJ. The pathology of wear in the bear model 104 heart valve prostheses. Circulation. 1977; 56:617–622.
  • Kim SW, Harvey J. Design of nonthrombogeni c polymer surfaces for blood contacting medical devices. Blood Purif. 1996;14:357–372.
  • Yamada KM, Olden K. Fibronectins: Adhesive glycopro- teins of cell surface and blood. Nature. 1978;275 (5677):179–184.
  • Mosher DF. Influence of proteins on platelet surface interaction. In: Salzman EW, ed. Interaction of Blood With Natural and Artiicial Surfaces. New York: Marcel Dekker; 1981:85.
  • Collins WE, Mosher DF, Tomasini BR, et al. A preliminary comparison of thrombogenic activity of vitronectin and other RGD-containing proteins when bound to surfaces. Ann NY Acad Sci. 1987;516:291–299.
  • Gluszko P, Rucinski B, Musial J, Wenger RK, Schmaier AH, Colman RW, et al. Fibrinogen receptors in platelets adhesion to surfaces of extracorporeal circuit. Am J Physiol. 1987; 252 (3 Pt 2): H615–621.
  • Pumphrey CW, Dawes J. Platelets alpha granule deple- tion: Findings in patients with prosthetic heart valves and following cardiopulmonar y bypass surgery. Thromb Res. 1983;30:257–264.
  • Yang Y, Franzen SF, Olin CL. In vivo comparison of hemocompatibility of materials used in mechanical heart valves. J Heart Valve Dis. 1996;5(5):532–537.
  • Slack SM, Turitto VT. Fluid dynamic and hemorheologi c considerations. Cardiovasc Pathol. 1993;2(3 Suppl):53S– 71S.
  • Roberts WC, Fishbein MC, Golden A. Cardiac pathology after valve replacement by disk prostheses: A study of 61 necropsy patients. Am J Cardiol. 1975;35:740–760.
  • Silver MD. Wear in Bjoric-Shiley heart valve prostheses recovered at necropsy or operation. J Thorac Cardiovasc Surg. 1980;79:693–699.
  • Schoen FJ. Carbon in heart valve prostheses: Foundations and clinical performance. In: Szycher ML, ed. Biocom- patible Polymers, Metals and Ceramics, Science and Technology. Westport, CT: Technomic; 1983:239–261.
  • Schoen FJ, Titus JL, Lawrie GM. Durability of paralytic carbon-containing heart valve prostheses. J Biomed Mater Res. 1982;16:559–570.
  • Ozaki Y, Wika KE, Matsuyoshi T. Platelets are deposited early postoperative on the leaflet of a mechanical heart valve in sheep without postoperative anticoagulation or antiplatelets: A scanning electron microscopic observa- tion of pyrolytic carbon surface in a mechanical heart valve. ASAIO J. 1996;42:M750–754.
  • Goodman SL, Tweden KS, Albrecht RM. Platelet interac- tion with pyrolytic carbon heart-valve leaflets. J Biomed Mater Res. 1996;32(2):249–258.
  • Dion I, Roques X, Baquey CH, et al. Hemocompatibility of diamond-like carbon coating. Bio-Med Mater. Eng. 1993;3:51–55.
  • Akutsu T, Modi VJ. Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two compo- nent laser Doppler anemometer system. Artif Organs. 1997;21(10):1110–1120.
  • Ellis JT, Healy TM, Fontaine AA, Weston MW, Jarret CA, Saxena R, et al. An in vitro investigation of retrograde flow felds of two bileaflet mechanical heart valves. J Heart Valve Dis. 1996;5(6):600–606.
  • Vallana F, Rinaldi S, Galletti PM, Nguyen A, Piwnica A. Pivot design in bileaflet valves. ASAIO J. 1992;38(3):M600- M606.
  • Pietrabissa R, Marconi W, Fumero R. Principle of opera- tion, design criteria and fluid dynamic of a new bileaflet heart valve prosthesis. Int J Art Organs. 1991;14(7):430- 434.
  • Kumar N, Singh B, Devital S, et al. Development of hermetic scratch resistant diamond like carbon coatings for silica optical fbers. Univ PA Mater Sci. 1997;10–11 (4): 10–14.
  • Thomson LA, Law FC, Rushton N, et al. Biocompatibility of diamond-like carbon coating. Biomaterials. 1991;12:37–40.
  • Kim SW, Wisniewski S, Lee ES, et al. Role of protein and fatty acid, adsorption on platelet adhesion and aggregation at the blood polymer interface. J Biomed Mater Res Symp. 1977;8:23–31.
  • Yasuda H, Gazicki M. Biomedical applications of plasma polymerization and plasma treatment of polymer surfaces. Biomaterials. 1982;3:68–77.
  • Yasuda H, Bumgarner MO, Mason RG. Lindholm blood co- agulation test values of some glow discharge polymer sur- faces. Biomater Med Dev Artif Organs. 1976;4:307–321.
  • Aronsson BO, Lausmaa J, Kasemo B. Glow discharge plasma treatment for surface cleaning and modifcation of metallic biomaterials. J Biomed Mater Res. 1997; 35(1):49–73.
  • Yasuda H. Glow discharge polymerization. J Polym Sci Macromol Rev. 1981;16:199–293.
  • Hudis M. Plasma treatment of solid materials. In: Hollahan JP, Ball AJ, eds. Techniques and Applications of Plasma Chemistry. New York: Wiley; 1974.
  • Pratt KJ, Williams SK, Jarrell, BE. Enhance adherenc e of human adult endothelial cells to plasma discharge modifed polyethylene terephthalate. J Biomed Mater Res. 1989;23:1131–1147.
  • Dekker A, Reitsma K, Beugeling T, et al. Surface modi- fcation of hydrophobic polymers for improvement of endothelial cell-surface interations. Clin Mater. 1992;11:157–162.
  • Ortenwall P, Wadenvik H, Kutti J, Risberg B. Reduction in deposition of indium-111-labele d platelets after autologous endothelial cell seeding of Dacron aortic bifurcation grafts in humans: A preliminary report. J Vasc Surg. 1987;6:17–25.
  • Herring MB, Gardner A, Glover J. Dacron femoral popliteal bypass grafts seeded with mechanically derived endothelium: An update. ASAIO J. 1985;8:74.
  • Van Wachem PB, Beugering T, Feijen J, et al. Interaction of cultured human endothelial cells with polymeric sur- faces of different wettabilities. Biomaterials. 1985;6(6): 403–408.
  • Sipehia R. X-ray photoelectron spectroscopy studies, surface tension measurements, immobilization of hu- man serum albumin, human fbrinogen, and human fbronection onto ammonia plasma treated surfaces of biomaterials useful for cardiovascular implants and artifcial cornea implants. Biomater Art Cell Immune Biotech. 1993;21(5):647–658.
  • Baier RE, Depalma VA, Furuse A, et al. Thromboresistance of glass after glow discharge treatment in argon. J Biomed Mater Res. 1975;9:547–560.
  • Sharma CP, Joseph G. Note: Platelet adhesion to surfaces treated with glow discharge and albumin. J Biomed Mater Res. 1986;20:677–682.
  • Chrzanowski F, Goodman M, Tarnoff M, Li Y, Soll DB, Hewitt CW, Cilley JH, Ng AF, Marra SW, DelRossi AJ. The effects of surface modifcation of mechanical aortic valves on thrombogenicity. Scanning. 1998;20(3):189–190.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.