384
Views
0
CrossRef citations to date
0
Altmetric
Commentaries

Minimum reporting standards should be expected for preclinical radiobiology irradiators and dosimetry in the published literature

ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon & ORCID Icon show all
Pages 1-6 | Received 20 Jul 2023, Accepted 16 Aug 2023, Published online: 11 Sep 2023

References

  • Bell BI, Vercellino J, Brodin NP, Velten C, Nanduri LSY, Nagesh PKB, Tanaka KE, Fang Y, Wang Y, Macedo R, et al. 2022. Orthovoltage X-rays exhibit increased efficacy compared with γ-rays in preclinical irradiation. Cancer Res. 82(15):2678–2691. doi:10.1158/0008-5472.CAN-22-0656
  • Desrosiers M, DeWerd L, Deye J, Lindsay P, Murphy MK, Mitch M, Macchiarini F, Stojadinovic S, Stone H. 2013. The importance of dosimetry standardization in radiobiology. J Res Natl Inst Stan. 118:403–418.
  • DeWerd LA, Kunugi K. 2021. Accurate dosimetry for radiobiology. Int J Radiat Oncol Biol Phys. 111(5):e75–e81. doi:10.1016/j.ijrobp.2021.09.002
  • Dos Santos M, Paget V, Trompier F, Gruel G, Milliat F. 2021. Dosimetry for cell irradiation using orthovoltage (40-300 kV) X-ray facilities. J Vis Exp. 168:e61645. doi:10.3791/61645
  • Draeger E, Sawant A, Johnstone C, Koger B, Becker S, Vujaskovic Z, Jackson IL, Poirier Y. 2020. A dose of reality: How 20 years of incomplete physics and dosimetry reporting in radiobiology studies may have contributed to the reproducibility crisis. Int J Radiat Oncol Biol Phys. 106(2):243–252. doi:10.1016/j.ijrobp.2019.06.2545
  • Guillou M, L'Homme B, Trompier F, Gruel G, Prezado Y, Dos Santos M. 2022. Preclinical modeling of low energy X-rays radiological burn: dosimetry study by monte carlo simulations and EPR spectroscopy. Front Physiol. 13:1075665. doi:10.3389/fphys.2022.1075665
  • Hurst GS, Mills WA, Conte FP, Upton AC. 1956. Principles and techniques of mixed radiation dosimetry; application to acute lethality studies of mice with the cyclotron. Radiat Res. 4(1):49–64. doi:10.2307/3570391
  • Marcu LG, Bezak E, Sykes PJ. 2022. Radiation research journals need to stipulate minimal dosimetry requirements for publishing research using X-radiation exposures. Radiat Res. 198(2):204–206. doi:10.1667/RADE-22-00063.1
  • Pedersen KH, Kunugi KA, Hammer CG, Culberson WS, DeWerd LA. 2016. Radiation biology irradiator dose verification survey. Radiat Res. 185(2):163–168. doi:10.1667/RR14155.1
  • Poirier Y, Belley MD, Dewhirst MW, Yoshizumic TT, Down JD. 2020. Transitioning from gamma rays to X-rays for comparable biomedical research irradiations: energy matters. Radiat Res. 193(6):506–511. doi:10.1667/RADE-20-00039.1
  • Seed TM, Xiao S, Manley N, Nikolich-Zugich J, Pugh J, Van den Brink M, Hirabayashi Y, Yasutomo K, Iwama A, Koyasu S, et al. 2016. An interlaboratory comparison of dosimetry for a multi-institutional radiobiological research project: observations, problems, solutions and lessons learned. Int J Radiat Biol. 92(2):59–70. doi:10.3109/09553002.2015.1106024
  • Stern W, Zira S, Boyd C, Iliopulos I, Peiris P, Fedurin M. 2022. Alternative technologies meta study report. Laboratory BN: U.S. Department of Energy, Office of Nuclear Energy. Report No.: BNL-223583-2022-FORE. doi:10.2172/1895064
  • Stone HB, Bernhard EJ, Coleman CN, Deye J, Capala J, Mitchell JB, Brown JM. 2016. Preclinical data on efficacy of 10 drug-radiation combinations: evaluations, concerns, and recommendations. Transl Oncol. 9(1):46–56. doi:10.1016/j.tranon.2016.01.002
  • Stricklin DL, VanHorne-Sealy J, Rios CI, Scott Carnell LA, Taliaferro LP. 2021. Neutron radiobiology and dosimetry. Radiat Res. 195(5):480–496.
  • Trompier F, Baumann M, Barrios L, Gregoire E, Abend M, Ainsbury E, Barnard S, Barquinero JF, Bautista JA, Brzozowska B, et al. 2017. Investigation of the influence of calibration practices on cytogenetic laboratory performance for dose estimation. Int J Radiat Biol. 93(1):118–126. doi:10.1080/09553002.2016.1213455
  • Zoetelief J, Broerse JJ, Busscher FA, Hiestand WP, Julius HW, Jansen JT. 1997. Recent EULEP dosimetry intercomparisons for whole body irradiation of mice. European Late Effects Project group. Int J Radiat Biol. 72(5):627–632.
  • Zoetelief J, Broerse JJ, Davies RW, Octave-Prignot M, Rezvani M, Vergara JC, Toni MP. 2001. Protocol for X-ray dosimetry in radiobiology. Int J Radiat Biol. 77(7):817–835. doi:10.1080/09553000110050605

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.