References
- Bayer , C.W. and Black , M.S. 1988 . IAQ Evaluations of Three Office Buildings . ASHRAE Journal , 30 ( 7 ) July : 48 – 53 .
- Berglund , B. , Johansson , I. and Lindvall , T. 1982 . A Longitudinal Study of Air Contaminants in a Newly Built Preschool . Environ. Int. , 8 : 111 – 115 .
- Weitzman , D.J. , Axelrad , R.B. and Teichman , K. 1989 . Indoor Air Quality Problems at EPA Headquarters — A Case Study . Presented at Am Ind. Hyg. Conf. . May 21–26 1989 , St. Louis.
- Melius , J. , Wallingford , K. , Keenlyside , R. and Carpenter , J. . Indoor Air Quality — The NIOSH Experience . Ann. Am. Conf. Gov. Ind. Hyg. . Vol. 10 ,
- Dillon , H.K. , Oestenstad , R.V. , Rose , V.E. and Richard , M. 1987 . Indoor Air Quality Survey in a Suburban Office Building in the Southeastern U.S. . Proc. ASHRAE Conf. IAQ 87 . May 1987 , Arlington, VA.
- Robertson , G. 1988 . “ Source, Nature, and Symptomology of Indoor Air Pollutants ” . In Indoor and Ambient Air Quality , 311 – 19 . London : Selper .
- Collett , C.W. , Sterling , E.M. and Arundel , A.V. . Changing Sick Buildings into Healthy Buildings: Improving the Ventilation System . Proc. Healthy Buildings 88 . Vol. 3 , June , Stockholm, , Sweden
- Morey , P.R. and Rundus , R.E. . HVAC System Operational Performance Affect Airborne Fungal Levels in Occupied Spaces . Proc 3rd Int. Conf. on Indoor Air Quality and Climate . Vol. 3 , August , Stockholm, , Sweden
- Ogden , N.W. , Eudy , L.W. , Heavner , D.L. , Conrad , F.W. Jr. and Green , C.R. 1986 . Improved Gas Chromatographic Quantitation of Trace Levels of Environmental Nicotine . Paper presented at the 40th Tobacco Chemists’ Research Conference . October 1986 , Knoxville, TN.
- De Bortoli , M. , Knoppel , H. , Pecchio , E. , Peil , A. , Rogora , H. , Schauenburg , H. , Schlitt , H. and Vissers , H. 1986 . Concentrations of selected organic pollutants in indoor and outdoor air in northern Italy . Environ. Int. , 12 : 343 – 350 .
- Krause , C. , Mailahn , W. , Nagel , R. , Schulz , C. , Seifert , B. and Ullrich , D. 1987 . “ Occurrence of volatile organic compounds in the air of 500 homes in the Federal Republic of Germany ” . In Indoor Air '87 , Edited by: Seifert , B. , Esdorn , H. , Fischer , M. , Rüden , H. and Wegner , J. vol. 1 , 102 – 106 . Berlin : Institute for Water, Soil and Air Hygiene .
- Lebret , E. , van de Wiel , H.J. , Box , H.P. , Noij , D. and Boleij , J.S.M. 1986 . Volatile organic compounds in Dutch homes . Environ. Int. , 12 : 323 – 332 .
- Wallace , L.A. 1987 . The total exposure assessment methodology (TEAM) study: Summary and analysis , Vol. 1 , Washington DC : USEPA .
- Wallace , L. and Clayton , C.A. 1987 . “ Volatile organic compounds in 600 US homes: major sources of personal exposure ” . In Indoor Air ‘87 , Edited by: Seifert , B. , Esdorn , H. , Fischer , M. , Ruden , H. and Wegner , J. vol. 1 , 183 – 187 . Berlin : Institute for Water, Soil and Air Hygiene .
- WHO . 23–28 August 1987 . Working group on indoor air quality: Organic pollutants 23–28 August , Berlin (West)
- ASHRAE Standard . 1981 . Ventilation for Acceptable Indoor Air Quality , 62 – 81 . Atlanta, , Georgia : American Society of Heating, Refrigerating, and Air Conditioning Engineers .
- ASHRAE Standard . 1989 . Ventilation for Acceptable Indoor Air Quality , 62 – 89 . Atlanta, , Georgia : American Society of Heating, Refrigerating, and Air Conditioning Engineers .
- ASHRAE Standard . 1976 . Method of Testing Air‐Cleaning Devices Used in General Ventilation for Removing Particulate Matter , 52 – 76 . Atlanta, , Georgia : American Society of Heating, Refrigerating, and Air Conditioning Engineers .
- Fradkin , A. , Tobin , R.S. , Tarlo , S.M. , Tucic‐Porretta , M. and Malloch , D. 1987 . Species Identification of Airborne Molds and its Significance for the Detection of Indoor Pollution . J.A.P.C.A. , 37 ( 1 ) January : 51 – 53 .
- Col , G.T. , Samson , R.A. , Al‐Doory , Y. and Dowson , J.F. 1984 . “Mold Allergy” , Philadelphia, PA : Published by Lea and Febiges .