References
- Wu H C, Young S T, Kuo T S. A versatile multichannel direct-synthesized electrical stimulator for FES applications. IEEE Transact Instrument Measure 2002; 51: 2–9
- Chiou Y H, Luh J J, Chen S C, Lai J S, Kuo T S. The comparison of electromyographic pattern classifications with active and passive electrodes. Med Engineer Physics 2004; 26: 605–610
- Wijman C A, Stroh K C, Van Doren C L, Thrope G B, Peckham P H, Keith M W. Functional evaluation of quadriplegic patients using a hand neuroprosthesis. Arch Phys Med Rehabil 1990; 71: 1053–1057
- Nathan R H. Control strategies in FNS systems for the upper extremities. CRC Crit Rev Biomed Engineering 1993; 21: 313–397
- Graupe D, Kohn K H. A critical review of EMG-controlled electrical stimulation in paraplegics. CRC Crit Rev Biomed Engineering 1988; 15: 187–210
- Scoot T RD, Peckham P H, Kilgore K L. Tri-state myoelectric control of bilateral upper extremity neuroprostheses for tetraplegic individuals. IEEE Transact Rehabil Engineering 1996; 4: 251–263
- Grill J H, Peckham P H. Functional neuromuscular stimulation for combined control of elbow extension and hand grasp in C5 and C6 quadriplegics. IEEE Transact Rehabil Engineering 1998; 6: 190–199
- Crago P E, Nakai R J, Chizeck H J. Feedback regulation of hand grasp opening and contact force during stimulation of paralyzed muscle. IEEE Transact Biomed Engineering 1991; 38: 17–28
- Hines A E, Crago P E, Billian C. Hand opening by electrical stimulation in patients with spastic hemiplegia. IEEE Transact Rehabil Engineering 1995; 3: 193–205
- Kiwerski J. New possibilities of improving the function of the hand of patients with spastic hemiplegia. Int J Rehabil Res 1984; 7: 293–298
- Prochazka A, Gauthier M, Wieler M, Kenwell Z. The bionic glove: An electrical stimulator garment that provide controlled grasp and hand opening in quadriplegia. Arch Phys Med Rehabil 1997; 78: 608–614
- Chen Y L, Chang W H, Chen S C, Sheu P F, Chen W L. The development of a knee locker with closed-loop functional electrical stimulation (FES) for hemiplegia in gait training. Disabil Rehabil 2003; 25: 916–921
- Chang G C, Luh J J, Laio G D, Lai J S, Cheng C K, Kuo B L, Kuo T S. A neuro-control system for the knee joint position control with quadriceps stimulation. IEEE Transact Rehabil Engineering 1997; 5: 2–11
- Crago P E, Lan N, Veltink P H, Abbas J J, Kantor C. New control strategies for neuroprosthetic systems. J Rehabil Res Develop 1996; 33: 158–172
- Riener R, Fuhr T. Patient-driven control of FES-supported standing up: A simulation study. IEEE Transact Rehabil Engineering 1998; 6: 113–124
- Graupe D, Kohn K H, Basseas S. Above- and below-lesion EMG pattern mapping for controlling electrical stimulation of paraplegics to facilitate unbraced walker-assisted walking. J Biomed Engineering 1988; 10: 305–311
- Thorsen R, Spadone R, Ferrarin M. A pilot study of myoelectrically controlled FES of upper extremity. IEEE Transact Neural Syst Rehabil Engineering 2001; 9: 161–168
- Saxena S, Nikolic S, Popovic D. An EMG-controlled grasping system for tetraplegics. J Rehabil Res Develop 1995; 32: 17–24
- Chiou Y H, Luh J J, Chen S C, Lai J S, Kuo T S. Optimal strategy of the patient-driven command controller for restoring hand functions by functional electrical stimulation. Proceedings of the 25th Annual International Conference of the IEEE EMBS. 2003; 1551–1553
- Chiou Y H, Chen S C, Lai J S, Kuo T S. A noninvasive functional electrical stimulation system with patient-driven loop for hand function restoration. Proceedings of the 26th Annual International Conference of the IEEE EMBS. 2004; 4130–4132
- Popovic M B, Popovic D B, Sinkjaer T, Stefanovic A, Schwirtlich L. Restitution of reaching and grasping promoted by functional electrical therapy. Artificial Organs 2002; 26: 271–275
- Gritsenko V, Prochazka A. A functional electric stimulation-assisted exercise therapy system for hemiplegic hand function. Arch Phys Med Rehabil 2004; 85: 881–885