211
Views
10
CrossRef citations to date
0
Altmetric
Original Articles

Stresses in cement mantles of hip replacements: effect of femoral implant sizes, body mass index and bone quality

, , , &
Pages 501-510 | Received 15 Aug 2007, Accepted 04 Jan 2009, Published online: 30 Sep 2009

References

  • Bergmann , G , Graichen , F and Rohlmann , A . 1993 . Hip joint loading during walking and running, measured in two patients . J Biomech , 26 ( 8 ) : 969 – 990 .
  • Bowsher , JG and Shelton , JC . 2001 . A hip simulator study of the influence of patient activity level on the wear of cross-linked polyethylene under smooth and roughened femoral conditions . Wear , 250 : 167 – 179 .
  • Bryan, KJ. 1998. Novel prosthetic hip joint: mechanical design and analysis of the acetabular component. [PhD Thesis], [Ireland]: University of Limerick.
  • Canada Joint Replacement Registry. 2005. Total hip and total knee replacement in Canada. Canadian Institute for Health Information p. 1–87
  • Carter , DR , Vasu , R and Harris , WH . 1982 . Stress distributions in the acetabular region–II. Effects of cement thickness and metal backing of the total hip acetabular component . J Biomech , 15 ( 3 ) : 165 – 170 .
  • Choi , K , Kuhn , JL , Ciarelli , MJ and Goldstein , SA . 1990 . The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus . J Biomech , 23 ( 11 ) : 1103 – 1113 .
  • Cilingir , AC , Ucar , V and Kazan , R . 2007 . Three-dimensional finite element modeling of hemi-arthroplasty of human hip joint . Trends Biomater Artif Organs. , 21 ( 1 ) : 63 – 72 .
  • Crowninshield , RD , Maloney , WJ , Wentz , DH , Humphrey , SM and Blanchard , CR . 2004 . Biomechanics of large femoral heads: what they do and don't do . Clin Orthop Relat Res , 429 : 102 – 107 .
  • Dalstra, M. 1993. Biomechanical aspects of the pelvic bone and design criteria for acetabular prostheses. [PhD Thesis], [The Netherlands]: University of Njemegen.
  • Dalstra , M , Frich , LH and Sneppen , O . 1996 . “ The loss of load bearing capability in rheumatoid glenoids ” . Proceedings of the 10th European Society of Biomechanics 178
  • Haskess , JW . 1998 . “ Arthroplasty of hip ” . In Campbell's operative orthopaedics , 9th ed. 295 – 425 .
  • Hoeltzel , DA , Walt , MJ , Kyle , RF and Simon , FD . 1989 . The effects of femoral head size on the deformation of ultrahigh molecular weight polyethylene acetabular cups . J Biomech , 22 ( 11–12 ) : 1163 – 1173 .
  • Kuehn , KD , Ege , W and Gopp , U . 2005 . Acrylic bone cements: mechanical and physical properties . Orthop Clin North Am , 36 ( 1 ) : 29 – 39 .
  • Kurtz , S , Giddings , V , Muratoglu , O , O'Connor , D , Harris , W and Krevolin , J . 2000 . Stresses in highly crosslinked acetabular component for total hip replacement , 46th Annual Meeting, Orthopaedic Research Society, March 12–15, Orlando
  • Lamvohee, J-MS. 2007. Factors affecting the stability of cemented fixations of acetabular components in total hip replacements. [PhD Thesis], [Essex, UK]: Anglia Ruskin University.
  • Lamvohee , J-MS , Ingle , P , Cheah , K , Dowell , J and Mootanah , R . 2003 . “ Effect of bone property on stress distribution in a reconstructed hip joint ” . Proceedings of the International Symposium Computer Simulation in Biomechanics, Sydney 15
  • Lamvohee , J-MS , Mootanah , R , Cheah , K , Dowell , J and Ingle , P . 2006 . “ Computer methods in biomechanics and biomedical engineering ” . In Optimum thickness of cement mantle for hip replacement on patients with different acetabulae morphology, bone quality and body mass index , Edited by: Middleton , J , Shrive , NG and Evans , S . 61 – 66 . UK : First Numerics .
  • Lankester , BJA , Stoney , J , Gheduzzi , S , Miles , AW and Bannister , GC . 2004 . An in-vitro evaluation of optimal acetabular cement mantle thickness . J Bone Joint Surg , 86-B ( 1 ) : 75 – 76 .
  • Malchau , H , Herberts , P , Eisler , T , Garellick , G and Soderman , P . 2002 . The Swedish total hip replacement register . J Bone Joint Surg [A] , 84-A ( 2 ) : 2 – 20 .
  • Maxian , TA , Brown , TD , Pedersen , DR and Callaghan , JJ . 1996 . Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty . J Orthop Res , 14 ( 4 ) : 668 – 675 .
  • Mburu , G , Aspden , RM and Hutchison , JD . 1999 . Optimizing the configuration of cement keyholes for acetabular fixation in total hip replacement using Taguchi experimental design . Eng Med , 213 ( 6 ) : 485 – 492 .
  • Mootanah , R , Ingle , P , Dowell , J , Cheah , K and Shelton , JC . 2000 . Fixation of the acetabular cup in cemented total hip replacement: improving the anchorage hole profile using finite element method . Technol Health Care , 8 ( 6 ) : 343 – 355 .
  • Mootanah , R , Ingle , P , Allen , E , Cheah , K , Dowell , J , Jarrett , P and Shelton , JC . 2002 . Total hip replacement: improving the cement fixation of the acetabular component . Acta Bioeng Biomech , 4 : 257 – 258 .
  • Mootanah , R , Ingle , P , Dowell , J , Cheah , K and Shelton , JC . 2004 . Total hip replacement: results of a postal survey of current practice on the cement fixation of the acetabular cup in the UK . Hip Int , 14 ( 3 ) : 155 – 162 .
  • Morscher , EW . 1992 . Current status in acetabular fixation in primary total hip arthroplasty . Clin Orthop Relat Res , 274 : 172 – 187 .
  • Murphy , BP and Prendergast , PJ . 2000 . On the magnitude and variability of the fatigue strength of acrylic bone cement . Int J Fatigue , 22 : 855 – 864 .
  • Oh , I . 1983 . A comprehensive analysis of the factors affecting acetabular cup fixation and design in total hip replacement arthroplasty: a series of experimental and clinical studies . Hip , Vol. 11 : 129 – 177 .
  • Oh , I , Sander , TW and Treharne , RW . 1985 . Total hip acetabular cup flange design and its effect on cement fixation . Clin Orthop Relat Res , 195 : 304 – 309 .
  • Oka , M . 1993 . “ Hip biomechanics ” . In Load-bearing mechanisms of natural and artificial joints , Edited by: Ismura , S , Akamatsu , T , Azuma , H , Sawai , S and Tanaka , S . 255 – 263 . Tokyo : Springer-Verlag .
  • Oki , H , Ando , M , Omori , H , Okumura , Y , Negoro , K , Uchida , K and Baba , H . 2004 . Relation between vertical orientation and stability of acetabular component in the dysplastic hip simulated by nonlinear three-dimensional finite element method . Artif Organs , 28 ( 11 ) : 1050 – 1054 .
  • Paul , JP . 1967 . Forces transmitted by joints in the human body . Eng Med , 181 ( 3 ) : 8 – 15 .
  • Phillips , ATM , Pankaj , P , Usmani , AS and Howie , CR . 2004 . The effect of acetabular cup size on the short-term stability of revision hip arthroplasty: a finite element investigation . Eng Med , 218 ( 4 ) : 239 – 249 .
  • Schmoelz, W. 2001. Factors contributing to the loosening of femoral stems in total hip arthroplasty. [PhD Thesis], [Glasgow, Scotland]: Glasgow Caledonian University.
  • Stansfield, BW. 2000. Hip joint forces: hip joint forces of 40 to 60 year old normal and total hip replacement subjects during walking and stair, ramp and camber negotiation. [PhD Thesis], [Glasgow, Scotland]: University of Strathclyde.
  • Thompson , MS , Dawson , T , Kuiper , JH , Northmore-Ball , MD and Tanner , KE . 2000 . Acetabular morphology and resurfacing design . J Biomech , 33 ( 12 ) : 1645 – 1653 .
  • Unigraphics Product Lifecycle Management UGS PLM Solutions. 2004. I-Deas help Library
  • Wirz , D , Daniels , AU , Gopfert , B and Morscher , EW . 2005 . Clinical development and current status: Europe . Orthop Clin North Am , 36 ( 1 ) : 63 – 73 .
  • Wu , G , Siegler , S , Allard , P , Kirtley , C , Leardini , A , Rosenbaum , D , Whittle , M , D'Lima , DD , Cristofolini , L , Witte , H , Schmid , O and Stokes , I . 2004 . Standardization and Terminology Committee of the International Society of Biomechanics, ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion–part I: ankle, hip, and spine . Int Soc Biomech, J Biomech , 35 ( 4 ) : 543 – 548 .
  • Zant , NP , Heaton-Adegbile , P , Hussell , JG and Tong , J . 2008 . In vitro fatigue failure of cemented acetbular replacements: a hip simulator study . J Biomech Eng , 130 ( 2 ) : 021019

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.