404
Views
23
CrossRef citations to date
0
Altmetric
Original Articles

Experimental and probabilistic analysis of distal femoral periprosthetic fracture: a comparison of locking plate and intramedullary nail fixation. Part B: probabilistic investigation

, , &
Pages 175-182 | Received 31 May 2010, Accepted 08 Nov 2010, Published online: 18 Feb 2011

References

  • Benzley , SE , Perry , E , Merkley , K , Clark , B and Sjaardama , G . A comparison of all hexagonal and all tetrahedral finite element meshes for elastic and elasto-plastic analysis . Proceedings of the 4th Annual International Meshing Roundtable, Sandia National Laboratory .
  • Bottlang , M , Doornink , J , Byrd , GD , Fitzpatrick , DC and Madey , SM . 2009 . A non-locking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis . J Bone Joint Surg Am , 91 ( 3 ) : 620 – 627 .
  • Bougherara , H , Zdero , R , Miric , M , Shah , S , Hardisty , M , Zalzal , P and Schemitsch , EH . 2009 . The biomechanics of the T2 femoral nailing system: a comparison of synthetic femurs with finite element analysis . Proc Inst Mech Eng H , 223 ( 3 ) : 303 – 314 .
  • Bucholz , RW , Court-Brown , C and Heckman , JD , eds. 2009 . “ Periprosthetic fractures ” . In Rockwood & Green's fractures in adults , Philadelphia, PA : Lippincott Williams & Wilkins . editors
  • Chen , S-H , Yu , T-C , Chang , CH and Lu , YC . 2008 . Biomechanical analysis of retrograde intramedullary nail fixation in distal femoral fractures . Knee , 15 ( 5 ) : 384 – 389 .
  • Cochran , JR , Lyon , WF and Smith , L . 1941 . Actual holding power of various screws in bone . Ann Surg , 114 ( 3 ) : 376 – 384 .
  • Cornell , C . 2005 . Fixation considerations in osteoporotic bone fractures . Curr Opin Orthop , 16 : 376 – 381 .
  • Dopico-Gonzalez , C , New , AM and Browne , M . 2009 . Probabilistic analysis of an uncemented total hip replacement . Med Eng Phys , 31 ( 4 ) : 470 – 476 .
  • Egol , KA , Kubiak , EN , Fulkerson , E , Kummer , FJ and Koval , KJ . 2004 . Biomechanics of locked plates and screws . J Orthop Trauma , 18 ( 8 ) : 488 – 493 .
  • Evans , FG . 1973 . Mechanical properties of bone , Springfield, IL : Charles C Thomas .
  • Firoozbakhsh , K , Behzadi , K , DeCoster , TA , Moneim , MS and Naraghi , FF . 1995 . Mechanics of retrograde nail versus plate fixation for supracondylar femur fractures . J Orthop Trauma , 9 ( 2 ) : 152 – 157 .
  • Fung , YC . 1993 . Biomechanics: mechanical properties of living tissues , New York, NY : Springer-Verlag .
  • Heiney , JP , Barnett , MD , Vrabec , GA , Schoenfeld , AJ , Baji , A and Njus , GO . 2009 . Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary nail, dynamic condylar screw, and locking compression plate condylar plate . J Trauma , 66 ( 2 ) : 443 – 449 .
  • Johnson , KD , Tencer , AF , Blumenthal , S , August , A and Johnston , DW . 1986 . Biomechanical performance of locked intramedullary nail systems in comminuted femoral shaft fractures . Clin Orthop Relat Res , : 151 – 161 .
  • Leahy M. 2010. When locking plates fail. AAOS Now. May 2010 Issue. http://www.aaos.org/news/aaosnow/may10/clinical4.asp
  • Miranda , MA . 2007 . Locking plate technology and its role in osteoporotic fractures . Injury , 38 ( 3 Suppl ) : S35 – S39 .
  • Montgomery , DC and Runger , GC . 2003 . Applied statistics and probability for engineers , 3rd ed , New York, NY : Wiley .
  • National Osteoporosis Foundation. 2010. Fast facts on osteoporosis. http://www.nof.org/osteoporosis/diseasefacts.htm
  • Nowak , AS and Collins , KR . 2000 . Reliability of structures , New York, NY : McGraw-Hill .
  • Pacific Research Laboratories, Inc. 2007. Sawbones Catalog
  • Perren , SM . 2002 . Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a balance between stability and biology . J Bone Joint Surg Br , 84 ( 8 ) : 1093 – 1110 .
  • Ruedi , TP , Buckley , RE and Moran , CG . 2007 . AO principles of fracture management , New York, NY : Thieme .
  • Salas C, Mercer D, DeCoster TA, Reda Taha MM. 2010. Experimental and probabilistic analysis of distal femoral periprosthetic fracture: a comparison of locking plate and intramedullary nail fixation. Part A: experimental investigation. Comput Methods Biomech Biomed Eng. In press
  • Schemitsch , EH , Zdero , R , Rose , S and Papini , M . 2007 . Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs . J Biomech Eng , 129 ( 2 ) : 289 – 293 .
  • Snow , M , Thompson , G and Turner , PG . 2008 . A mechanical comparison of the locking compression plate and the low contact-dynamic compression plate in an osteoporotic bone model . J Orthop Trauma , 22 ( 2 ) : 121 – 125 .
  • Sommer , C , Gautier , E , Muller , M , Helfet , DL and Wagner , M . 2003, Nov . First clinical results of the locking compression plate (LCP) . Injury , 34 ( 2 Suppl ) : B43 – B54 .
  • Sowmianarayanan , S , Chandrasekaran , A and Krishna Kumar , R . 2008 . Finite element analysis of a subtrochanteric fractured femur with dynamic hip screw, dynamic condylar screw, and proximal femur nail implants – a comparative study . Proc Inst Mech Eng H , 222 ( 1 ) : 117 – 127 .
  • Verhulp , E , van Rietbergen , B and Huiskes , R . 2006 . Comparison of micro-level and continuum-level voxel models of the proximal femur . J Biomech , 39 ( 16 ) : 2951 – 2957 .
  • Wilkens , KJ , Curtiss , S and Lee , MA . 2008 . Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison . J Orthop Trauma , 22 ( 9 ) : 624 – 628 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.