253
Views
5
CrossRef citations to date
0
Altmetric
Original Articles

Sensitivity analysis of hip joint centre estimation based on three-dimensional CT scans

, &
Pages 539-546 | Received 01 Apr 2010, Accepted 13 Dec 2010, Published online: 17 Feb 2011

References

  • Ahn , SJ , Rauh , W and Warnecke , H-J . 2001 . Least-squares orthogonal distances fitting of circle, sphere, ellipse, hyperbola, and parabola . Patt Recog , 34 ( 12 ) : 2283 – 2303 .
  • Cereatti , A , Donati , M , Camomilla , V , Margheritini , F and Cappozzo , A . 2009 . Hip joint centre location: an ex vivo study . J Biomech , 42 ( 7 ) : 818 – 823 .
  • Dandachli , W , Nakhla , A , Iranpour , F , Kannan , V and Cobb , JP . 2009 . Can the acetabular position be derived from a pelvic frame of reference? . Clin Orthop Relat Res , 467 ( 4 ) : 886 – 893 .
  • Della Croce , U , Leardini , A , Chiari , L and Cappozzo , A . 2005 . Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics . Gait Posture , 21 ( 2 ) : 226 – 237 .
  • Falcão , AX and Udupa , JK . 2000 . A 3D generalization of user-steered live-wire segmentation . Med Image Anal , 4 ( 4 ) : 389 – 402 .
  • Forbes , AB . 1989 . Least squares best fit geometric elements , Teddington : National Physical Laboratory . Report No: NPL-DITC-140/89
  • Gelaude , F , Vander Sloten , J and Lauwers , B . 2008 . Accuracy assessment of CT-based outer surface femur meshes . Comput Aided Surg , 13 ( 4 ) : 188 – 199 .
  • Gilles , B , Christophe , FK , Magnenat-Thalmann , N , Becker , CD , Duc , SR , Menetrey , J and Hoffmeyer , P . 2009 . MRI-based assessment of hip joint translations . J Biomech , 42 ( 9 ) : 1201 – 1205 .
  • Harrington , ME , Zavatsky , AB , Lawson , SEM , Yuan , Z and Theologis , TN . 2007 . Prediction of the hip joint centre in adults, children, and patients with cerebral palsy based on magnetic resonance imaging . J Biomech , 40 ( 3 ) : 595 – 602 .
  • Jin , S , Lewis , RR and West , D . 2005 . A comparison of algorithms for vertex normal computation . Visual Comput , 21 ( 1–2 ) : 71 – 82 .
  • Kåsa , I . 1976 . A circle fitting procedure and its error analysis . IEEE Trans Instrum Meas , 25 ( 1 ) : 8 – 14 .
  • Kim , JS , Park , TS , Park , SB , Kim , JS , Kim , IY and Kim , SI . 2000 . Measurement of femoral neck anteversion in 3D. Part 2: 3D modelling method . Med Biol Eng Comput , 38 ( 6 ) : 610 – 616 .
  • Leardini , A , Cappozzo , A , Catani , F , Toksvig-Larsen , S , Petitto , A , Sforza , V , Cassanelli , G and Giannini , S . 1999 . Validation of a functional method for the estimation of hip joint centre location . J Biomech , 32 ( 1 ) : 99 – 103 .
  • Lenaerts , G , Bartels , W , Gelaude , F , Mulier , M , Spaepen , A , Van der Perre , G and Jonkers , I . 2009 . Subject-specific hip geometry and hip joint centre location affects calculated contact forces at the hip during gait . J Biomech , 42 ( 9 ) : 1246 – 1251 .
  • Mahaisavariya , B , Sitthiseripratip , K , Tongdee , T , Bohez , ELJ , Vander Sloten , J and Oris , P . 2002 . Morphological study of the proximal femur: a new method of geometrical assessment using 3-dimensional reverse engineering . Med Eng Phys , 24 ( 9 ) : 617 – 622 .
  • Max , N . 1999 . Weights for computing vertex normals from facet normals . J Graph Tools , 4 ( 2 ) : 1 – 6 .
  • Menschik , F . 1997 . The hip joint as a conchoid shape . J Biomech , 30 ( 9 ) : 971 – 973 .
  • Möller , T and Trumbore , B . 1997 . Fast, minimum storage ray/triangle intersection . J Graph Tools , 2 ( 1 ) : 21 – 28 .
  • Stagni , R , Leardini , A , Cappozzo , A , Grazia Benedetti , M and Cappello , A . 2000 . Effects of hip joint centre mislocation on gait analysis results . J Biomech , 33 ( 11 ) : 1479 – 1487 .
  • Stokdijk , M , Meskers , CGM , Veeger , HEJ , De Boer , YA and Rozing , PM . 1999 . Determination of the optimal elbow axis for evaluation of placement of prostheses . Clin Biomech , 14 ( 3 ) : 177 – 184 .
  • Sugano , N , Noble , PC and Kamaric , E . 1998 . A comparison of alternative methods of measuring femoral anteversion . J Comput Assist Tomogr , 22 ( 4 ) : 610 – 614 .
  • Woltring , HJ . 1990 . “ Model and measurement error influences in data processing ” . In Biomechanics of human movement: applications in rehabilitation, sport and ergonomics , Edited by: Cappozzo , A and Berme , P . 203 – 237 . Worthington (OH) : Bertec Corporation .
  • Zoroofi , RA , Sato , Y , Nishii , T , Sugano , N , Yoshikawa , H and Tamura , S . 2004 . Automated segmentation of necrotic femoral head from 3D MR data . Comput Med Imaging Graph , 28 ( 5 ) : 267 – 278 .
  • Zoroofi , RA , Sato , Y , Sasama , T , Nishii , T , Sugano , N , Yonenobu , K , Yoshikawa , H , Ochi , T and Tamura , S . 2003 . Automated segmentation of acetabulum and femoral head from 3-D CT images . IEEE Trans Inf Technol Biomed , 7 ( 4 ) : 329 – 343 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.