References
- AndriacchiTP, DyrbyCO. 2005. Interactions between kinematics and loading during walking for the normal and ACL deficient knee. J Biomech. 38(2):293–298.
- AsakawaDS, PappasGP, BlemkerSS, DraceJE, DelpSL. 2003. Cine phase-contrast magnetic resonance imaging as a tool for quantification of skeletal muscle motion. Semin Musculoskelet Radiol. 7(4):287–295.
- BinghamJ, LiG. 2006. An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system. J Biomech Eng. 128(4):588–595.
- BorotikarBS, Sipprell, 3rd, WH, WibleEE, SheehanFT. 2012. A methodology to accurately quantify patellofemoral cartilage contact kinematics by combining 3D image shape registration and cine-PC MRI velocity data. J Biomech. 45(6):1117–1122.
- CriscoJJ, WolfeSW, NeuCP, PikeS. 2001. Advances in the in vivo measurement of normal and abnormal carpal kinematics. The Orthopedic clinics of North America. 32(2):219–231.
- FreglyBJ, BanksSA, D'LimaDD, Colwell, Jr, CW. 2008. Sensitivity of knee replacement contact calculations to kinematic measurement errors. J Orthop Res. 26(9):1173–1179.
- GardnerMJ, CriscoJJ, WolfeSW. 2006. Carpal kinematics. Hand Clin. 22(4):413–420.
- GotoA, MoritomoH, MuraseT, OkaK, SugamotoK, ArimuraT, MasumotoJ, TamuraS, YoshikawaH, OchiT. 2005. In vivo three-dimensional wrist motion analysis using magnetic resonance imaging and volume-based registration. J Orthop Res. 23(4):750–756.
- HallM, StevermerCA, GilletteJC. 2012. Gait analysis post anterior cruciate ligament reconstruction: knee osteoarthritis perspective. Gait Posture. 36(1):56–60.
- JohnsonJE, LeeP, McIffTE, TobyEB, FischerKJ. 2013. Scapholunate ligament injury adversely alters in vivo wrist joint mechanics: an MRI-based modeling study. J Orthop Res. 31(9):1455–1460.
- JohnsonJE, McIffTE, LeeP, TobyEB, FischerKJ. 2014. Validation of radiocarpal joint contact models based on images from a clinical MRI scanner. Comput Methods Biomech Biomed Eng. 17(4):378–387.
- KwakSD, BlankevoortL, AteshianGA. 2000. A mathematical formulation for 3D quasi-static multibody models of diarthrodial joints. Comput Methods Biomech Biomed Eng. 3(1):41–64.
- LiL, PatilS, SteklovN, BaeW, Temple-WongM, D'LimaDD, SahRL, FreglyBJ. 2011. Computational wear simulation of patellofemoral articular cartilage during in vitro testing. J Biomech. 44(8):1507–1513.
- ManuelJ, MoranSL. 2010. The diagnosis and treatment of scapholunate instability. Hand Clin. 26(1):129–144.
- MoojenTM, SnelJG, RittMJPF, VenemaHW, KauerJMG, BosKE. 2003. In vivo analysis of carpal kinematics and comparative review of the literature. J Hand Surg. 28(1):81–87.
- Moro-okaTA, HamaiS, MiuraH, ShimotoT, HigakiH, FreglyBJ, IwamotoY, BanksSA. 2007. Can magnetic resonance imaging-derived bone models be used for accurate motion measurement with single-plane three-dimensional shape registration?J Orthop Res. 25(7):867–872.
- NoehrenB, ManalK, DavisI. 2010. Improving between-day kinematic reliability using a marker placement device. J Orthop Res. 28(11):1405–1410.
- RogersBP, HaughtonVM, ArfanakisK, MeyerandME. 2002. Application of image registration to measurement of intervertebral rotation in the lumbar spine. Magn Reson Med. 48(6):1072–1075.
- SvedmarkP, TullbergT, NozME, Maguire, Jr, GQ, ZeleznikMP, WeidenhielmL, NemethG, OlivecronaH. 2012. Three-dimensional movements of the lumbar spine facet joints and segmental movements: in vivo examinations of normal subjects with a new non-invasive method. Eur Spine J. 21(4):599–605.
- TaySC, van RietR, KazunariT, KoffMF, AmramiKK, AnKN, BergerRA. 2008. A method for in-vivo kinematic analysis of the forearm. J Biomech. 41(1):56–62.
- WoltringHJ. 1994. 3-D attitude representation of human joints: a standardization proposal. J Biomech. 27(12):1399–1414.
- YaoJ, SaloAD, LeeJ, LernerAL. 2008. Sensitivity of tibio-menisco-femoral joint contact behavior to variations in knee kinematics. J Biomech. 41(2):390–398.
- ZhengG, ZhangX. 2010. Computer assisted determination of acetabular cup orientation using 2D–3D image registration. Int J Comput Assist Radiol Surg. 5(5):437–447.
- ZhuZ, MassiminiDF, WangG, WarnerJJ, LiG. 2012. The accuracy and repeatability of an automatic 2D-3D fluoroscopic image-model registration technique for determining shoulder joint kinematics. Med Eng Phys. 34(9):1303–1309.