Custom sizing of lower limb exoskeleton actuators using gait dynamic modelling of children with cerebral palsy

, , , , &
Pages 1519-1524 | Received 07 Oct 2015, Accepted 25 Feb 2016, Published online: 15 Mar 2016

References

  • Aguirre-Ollinger G, Colgate JE, Peshkin MA, Goswami A. 2007. A 1-DOF assistive exoskeleton with virtual negative damping: effects on the kinematic response of the lower limbs. IEEE/RSJ International Conference on Intelligent Robots and Systems San Diego, CA, USA; p. 1938–1944. doi:10.1109/IROS.2007.4399147
  • Ballaz L, Robert M, Parent A, Prince F, Lemay M. 2014. Impaired visually guided weight-shifting ability in children with cerebral palsy. Res Dev Disabil. 35:1970–1977. doi:10.1016/j.ridd.2014.04.019. PubMed.
  • Casolo F, Cinquemani S, Cocetta M. 2008. On active lower limb exoskeletons actuators. Proceeding of the 5th International Symposium on Mechatronics and its Applications (ISMA); Amman; p. 1–6. doi:10.1109/ISMA.2008.4648796
  • Cenciarini M, Dollar A. 2011. Biomechanical considerations in the design of lower limb exoskeletons. IEEE International Conference on Rehabilitation Robotics; ETH Zurich; p. 1–6. doi:10.1109/ICORR.2011.5975366
  • Dal Maso F, Raison M, Lundberg A, Arndt T, Allard P, Begon M. 2014. Glenohumeral translations in full range of motion, daily-living and sport activities. Congress of the Canadian Orthopaedic Research Society (CORS): Montreal.
  • Dollar A, Herr H. 2008. Design of a quasi-passive knee exoskeleton to assist running. IEEE/RSJ International Conference on Intelligent Robots and Systems; Nice; p. 747–754. doi:10.1109/IROS.2008.4651202
  • Gilliaux M, Renders A, Dispa D, Holvoet D, Sapin J, Dehez B, Detrembleur C, Lejeune TM, Stoquart G. 2015. Upper limb robot-assisted therapy in cerebral palsy: a single-blind randomized controlled trial. Neurorehabil Neural Repair. 29:183–192. doi:10.1177/1545968314541172
  • Hernandez S, Raison M, Baron L, Achiche S. 2015. Refinement of exoskeleton design using multibody modeling: an overview. CCToMM M3 Symposium on Mechanisms, Machines and Mechatronics; Ottawa.
  • Jokar M, Yousefi-Koma A, Taherifar A. 2014. Determination of the required torque for actuation of a lower-limb exoskeleton during level walking. 21st Annual International Conference on Mechanical Engineering-ISME; Tehran; p. 1–6. doi:10.13140/2.1.3153.3444
  • Labruyère R, Gerber CN, Birrer-Brütsch K, Meyer-Heim A, Van Hedel HJ. 2013. Requirements for an impact of a serious game for neuro-pediatric robot-assisted gait training. Res Dev Disabil. 34:3906–3915. doi:10.1016/j.ridd.07.031
  • Mohebbi A, Achiche S, Baron L. 2014. Mechatronic multicriteria profile (MMP) for conceptual design of a robotic visual servoing system. ASME 2014 12th Biennial Conf on Eng Systems Design and Analysis; Copenhagen; p. V003T15A015; 10 pages. doi:10.1115/ESDA2014-20414
  • Palisano R, Rosenbaum P, Walter S, Russell D, Wood E, Galuppi B. 1997. Development and reliability of a system to classify gross motor function in children with cerebral palsy. Dev Med Child Neurol. 39:214–223. doi:10.1111/j.1469-8749
  • Pons JL (editor.) 2008. Front Matter, Wearable robots: Biomechatronic Exoskeletons, John Wiley & Sons, Ltd, Chichester, UK. p. 47–88. doi:10.1002/9780470987667.fmatter10.1002/9780470987667
  • Raison M, Detrembleur C, Fisette P, Samin JC, Willems PY. 2007a. Determination of three-dimensional joint efforts of a subject walking on a treadmill. Comput Methods Biomech Biomed Eng. 8;Suppl 1:229–230.
  • Raison M, Gaudez CC, Le Bozec S, Willems PY. 2007b. Determination of joint efforts in the human body during maximum ramp pushing efforts. J Biomech. 40:627–633.10.1016/j.jbiomech.2006.01.023
  • Redlarski G, Blecharz K, Dąbkowski M, Pałkowski, A, Tojza P.M. 2012. Comparative analysis of exoskeletal actuators. Pomiary, Automatyka, Robotyka, Gdańsk, Poland. Vol. R.16, nr 12, p. 133–138.
  • Riener R, Rabuffetti M, Frigo C. 2002. Stair ascent and descent at different inclinations. Gait Posture. 15:32–44.
  • Riener R, Dislaki E, Keller U, Koenig A, Van Hedel H, Nagle A. 2013. Virtual riality aided training of combined arm and leg movements of children with CP. Stud Health Technol Inform. 184:349–355.
  • Rossi S, Colazza A, Petrarca M, Castelli E, Cappa P, Krebs HI. 2013. Feasibility study of a wearable exoskeleton for children: is the gait altered by adding masses on lower limbs? PLoS One. 8:e73139. doi:10.1371/journal.pone.0073139
  • Schulte R. 1962. The Characteristics of the McKibben artificial muscle. Appl External Power Prosthetics Orthetics. 874:94–115.
  • Winter DA. 1987. The biomechanics and motor control of human gait: normal, elderly and pathological.  University of Waterloo Press, Ontario. p. 64.
  • Zoss A, Kazerooni H. 2006. Design of an electrically actuated lower extremity exoskeleton. Adv Robotics. 20:967–988. doi: 10.1163/15685530677839403010.1163/156855306778394030

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.