References
- Amaritsakul Y, Chao C-K, Lin J. 2014. Biomechanical evaluation of bending strength of spinal pedicle screws, including cylindrical, conical, dual core and double dual core designs using numerical simulations and mechanical tests. Med Eng Phys [Internet]. 36:1218–1223. http://www.ncbi.nlm.nih.gov/pubmed/25060212.10.1016/j.medengphy.2014.06.014
- Arslan AK, Demir T, Örmeci MF, Camuscu N, Türeyen K. 2013. Postfusion pullout strength comparison of a novel pedicle screw with classical pedicle screws on synthetic foams. Proc Inst Mech Eng Part H J Eng Med [Internet]. 227:114–119. http://pih.sagepub.com/lookup/doi/10.1177/0954411912463323.10.1177/0954411912463323
- Aycan MF, Tolunay T, Demir T, Yaman ME, Usta Y. 2017. Pullout performance comparison of novel expandable pedicle screw with expandable poly-ether-ether-ketone shells and cement-augmented pedicle screws. Proc Inst Mech Eng Part H J Eng Med [Internet]. 231:169–175. http://journals.sagepub.com/doi/10.1177/0954411916687792.10.1177/0954411916687792
- Bartel DL, Davy DT, Keaveny TM. 2006. Orthopaedic biomechanics, mechanics and design in musculoskeletal systems. London: Pearson Education Inc.
- Cetin E, Özkaya M, Güler ÜO, Acaroglu E, Demir T. 2015. Evaluation of the effect of fixation angle between polyaxial pedicle screw head and rod on the failure of screw-rod connection. Appl Bionics Biomech. 2015:9 pages.
- Chamoli U, Diwan AD, Tsafnat N. 2014. Pedicle screw-based posterior dynamic stabilizers for degenerative spine: In vitro biomechanical testing and clinical outcomes. J Biomed Mater Res A [Internet]. 102:3324–3340. http://www.ncbi.nlm.nih.gov/pubmed/24382799.10.1002/jbm.a.v102.9
- Chao C-K, Hsu C-C, Wang J-L, Lin J. 2007. Increasing bending strength of tibial locking screws: mechanical tests and finite element analyses. Clin Biomech (Bristol, Avon) [Internet]. 22:59–66. http://www.ncbi.nlm.nih.gov/pubmed/16959388
- Chao C-K, Hsu C-C, Wang J-L, Lin J. 2008. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses. J Spinal Disord Tech. 21:130–138.10.1097/BSD.0b013e318073cc4b
- Chatzistergos PE, Magnissalis EA, Kourkoulis SK. 2010. A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model. Med Eng Phys [Internet]. 32:145–154. http://www.ncbi.nlm.nih.gov/pubmed/19945333.10.1016/j.medengphy.2009.11.003
- Chen SI, Lin RM, Chang CH. 2003. Biomechanical investigation of pedicle screw–vertebrae complex: a finite element approach using bonded and contact interface conditions. Med Eng Phys [Internet]. 25:275–282. http://linkinghub.elsevier.com/retrieve/pii/S1350453302002199.10.1016/S1350-4533(02)00219-9
- Chou WK, Chien A, Wang JL. 2014. Pullout strength of thoracic pedicle screws improved with cortical bone ratio: a cadaveric study. J Orthop Sci. 19(6):900–906.
- Combres Y. 2010. Propriétés du titane et de ses alliages [Properties of titanium and its alloys] [Internet]. [accessed 2015 Oct 16]. http://www.techniques-ingenieur.fr/base-documentaire/biomedical-pharma-th15/biomateriaux-et-biomecanique-42606210/proprietes-du-titane-et-de-ses-alliages-m4780/.
- Dammak M, Shirazi-Adl A, Zukor DJ. 1997. Analysis of cementless implants using interface nonlinear friction - Experimental and finite element studies. J Biomech. 30:121–129.10.1016/S0021-9290(96)00110-8
- Demir T, Basgül C. 2015. The pullout performance of pedicle screws. In: Altenbach H, da Silva L F M, Öchsner A, editors. Springer Briefs in Applied Sciences and Technology - Computational Mechanics. Springer International Publishing.
- Demir T, Camuşcu N, Türeyen K. 2012. Design and biomechanical testing of pedicle screw for osteoporotic incidents. Proc Inst Mech Eng Part H J Eng Med [Internet]. 226:256–262. http://pih.sagepub.com/content/226/3/256.short\nhttp://pih.sagepub.com/lookup/doi/10.1177/0954411911434680.10.1177/0954411911434680
- Ebraheim NA, Xu R, Ahmad M, Yeasting RA. 1997. Projection of the thoracic pedicle and its morphometric analysis. Spine (Phila Pa 1976). 22:233–238.
- Faraj AA, Webb JK. 1997. Early complications of spinal pedicle screw. Eur Spine J. 6:324–326.10.1007/BF01142678
- Goulet RW, Goldstein SA, Ciarelli MJ, Kuhn JL, Brown MB, Feldkamp LA. 1994. The relationship between the structural and orthogonal compressive properties of trabecular bone. J Biomech. 27:375–389.10.1016/0021-9290(94)90014-0
- Hadjipavlou A, Enker P, Dupuis P, Katzman S, Silver J. 1996. The causes of failure in transpedicular spinal instrumentation and fusion. Int Orthop. 20:35–42.10.1007/s002640050024
- Hou S-M, Hsu C-C, Wang J-L, Chao C-K, Lin J. 2004. Mechanical tests and finite element models for bone holding power of tibial locking screws. Clin Biomech (Bristol, Avon) [Internet]. 19:738–745. http://www.ncbi.nlm.nih.gov/pubmed/15288461
- Hsu CC, Chao CK, Wang JL, Hou SM, Tsai YT, Lin J. 2005. Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses. J Orthop Res. 23:788–794.10.1016/j.orthres.2004.11.002
- Hulme PA, Boyd SK, Ferguson SJ. 2007. Regional variation in vertebral bone morphology and its contribution to vertebral fracture strength. Bone [Internet]. 41:946–957. http://www.ncbi.nlm.nih.gov/pubmed/17913613.10.1016/j.bone.2007.08.019
- Kang DG, Lehman RA, Wagner SC, Bevevino AJ, Bernstock JD, Gaume RE, Dmitriev AE. 2014. Pedicle screw reinsertion using previous pilot hole and trajectory does not reduce fixation strength. Spine. 39(20):1640–1647.
- Kim Y-Y, Choi W-S, Rhyu K-W. 2012. Assessment of pedicle screw pullout strength based on various screw designs and bone densities – an ex-vivo biomechanical study. Spine J [Internet]. 12:164–168. http://www.ncbi.nlm.nih.gov/pubmed/22336467.10.1016/j.spinee.2012.01.014
- Liljenqvist U, Hackenberg L, Link T, Halm H. 2001. Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. Acta Orthop Belg. 67:157–163.
- Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB. 1999. Complications associated with pedicle screws. J Bone Jt Surg. 81:1519–1528.10.2106/00004623-199911000-00003
- MacLeod AR, Pankaj P, Simpson AHRW. 2012. Does screw-bone interface modelling matter in finite element analyses? J Biomech [Internet]. 45:1712–1716. http://www.ncbi.nlm.nih.gov/pubmed/22537570.10.1016/j.jbiomech.2012.04.008
- MedTech Insight. 2006. European markets for spinal fusion products [Internet]. [accessed 2015 Oct 16]. http://www.medtechinsight.com/ReportA306.html.
- Mulier M. 2012. Functional anatomy of the human locomotor system: course notes. Leuven: Katholieke Universiteit Leuven.
- Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K. 2001. Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J. 1:402–407.10.1016/S1529-9430(01)00078-X
- Ordway N, Wilson T, Buerkle T, Yan HA. 2005. Lumbar pedicle screw fixation in osteoporotic bone: a technique utilizing PMMA and a fenestrated screw. In: Transactions of the 51st Annual Meeting of the Orthopaedic Research Society; February 20–23; Washington, DC.
- Ouellet JA, Arlet V. 2004. Surgical anatomy of the pelvis, sacrum, and lumbar spine relevant to spinal surgery. Semin Spine Surg [Internet]. 16:91–100. http://linkinghub.elsevier.com/retrieve/pii/S1040738304000346.10.1053/j.semss.2004.07.008
- Prud’homme M, Barrios C, Rouch P, Charles YP, Steib J-P, Skalli W. 2014. Clinical outcomes and complications after pedicle-anchored dynamic or hybrid lumbar spine stabilization: a systematic literature review. J Spinal Disord Tech [Internet]. http://www.scopus.com/inward/record.url?eid=2-s2.0-84905318535&partnerID=tZOtx3y1.
- Rajaee SS, Bae HW, Kanim LE, Delamarter RB. 2012. Spinal fusion in the United States: analysis of trends from 1998 to 2008. Spine (Phila Pa 1976) [Internet]. 37:67–76. http://linkinghub.elsevier.com/retrieve/pii/S1529943012001167.
- Rho JY, Hobatho MC, Ashman RB. 1995. Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys. 17:347–355.10.1016/1350-4533(95)97314-F
- Ritzel H, Amling M, Pösl M, Hahn M, Delling G. 1997. The thickness of human vertebral cortical bone and its changes in aging and osteoporosis: a histomorphometric analysis of the complete spinal column from thirty-seven autopsy specimens. J Bone Miner Res. 12:89–95.10.1359/jbmr.1997.12.1.89
- Rosa G, Clienti C, Mineo R, Audenino A. 2016. Experimental analysis of pedicle screws. Procedia Struct Integr [Internet]. 2:1244–1251. http://linkinghub.elsevier.com/retrieve/pii/S2452321616301676.10.1016/j.prostr.2016.06.159
- Shirazi-Adl A, Dammak M, Zukor DJ. 1994. Fixation pull-out response measurement of bone screws and porous-surfaced posts. J Biomech. 27:1249–1258.10.1016/0021-9290(94)90278-X
- Shirazi-Adl A, Patenaude O, Dammak M, Zukor D. 2001. Experimental and finite element comparison of various fixation designs in combined loads. J Biomech Eng. 123:391–395.10.1115/1.1395572
- Wang W, Baran GR, Garg H, Betz RR, Moumene M, Cahill PJ. 2014. The benefits of cement augmentation of pedicle screw fixation are increased in osteoporotic bone: a finite element analysis. Spine Deform [Internet]. 2:248–259. http://linkinghub.elsevier.com/retrieve/pii/S2212134X14000318.10.1016/j.jspd.2014.03.002
- World Health Organisation. 1994. Assessment of fracture risk and its implication to screening for postmenopausal osteoporosis. Geneva. Technical Report Number 843.
- Yaman O, Demir T, Arslan AK, Iyidiker MA, Tolunay T, Camuscu N, Ulutas M. 2015. The comparison of pullout strengths of various pedicle screw designs on synthetic foams and ovine vertebrae. Turk Neurosurg. 25:532–538.
- Zhang QH, Tan SH, Chou SM. 2004. Investigation of fixation screw pull-out strength on human spine. J Biomech [Internet]. 37:479–485. http://www.ncbi.nlm.nih.gov/pubmed/14996559.10.1016/j.jbiomech.2003.09.005
- Zhang QH, Tan SH, Chou SM. 2006. Effects of bone materials on the screw pull-out strength in human spine. Med Eng Phys [Internet]. 28:795–801. http://www.ncbi.nlm.nih.gov/pubmed/16414303.10.1016/j.medengphy.2005.11.009