References
- Blankevoort L, Huiskes R, de Lange A. 1988. The envelope of passive knee joint motion. J Biomech. 21:705–720.10.1016/0021-9290(88)90280-1
- Blankevoort L, Huiskes R, de Lange A. 1990. Helical axes of passive knee joint motions. J Biomech. 23:1219–1229.10.1016/0021-9290(90)90379-H
- Churchill DL, Incavo SJ, Johnson CC, Beynnon BD. 1998. The transepicondylar axis approximates the optimal flexion axis of the knee. Clin Orthop Relat Res: 111–118.10.1097/00003086-199811000-00016
- Cole GK, Nigg BM, Ronsky JL, Yeadon MR. 1993. Application of the joint coordinate system to three-dimensional joint attitude and movement representation: a standardization proposal. J Biomech Eng. 115:344–349.10.1115/1.2895496
- Colle F, Bignozzi S, Lopomo N, Zaffagnini S, Sun L, Marcacci M. 2012. Knee functional flexion axis in osteoarthritic patients: comparison in vivo with transepicondylar axis using a navigation system. Knee surgery, Sport Traumatol Arthrosc. 20:552–558.10.1007/s00167-011-1604-z
- Coughlin KM, Incavo SJ, Churchill DL, Beynnon BD. 2003. Tibial axis and patellar position relative to the femoral epicondylar axis during squatting. J Arthroplasty. 18:1048–1055.10.1016/S0883-5403(03)00449-2
- Dennis DA, Mahfouz MR, Komistek RD, Hoff W. 2005. In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics. J Biomech. 38:241–253.10.1016/j.jbiomech.2004.02.042
- Dhaher YY, Francis MJ. 2006. Determination of the abduction–adduction axis of rotation at the human knee: helical axis representation. J Orthop Res. 24:2187–2200.10.1002/(ISSN)1554-527X
- Fleming BC, Beynnon BD, Tohyama H, Johnson RJ, Nichols CE, Renstrom P, Pope MH. 1994. Determination of a zero strain reference for the anteromedial band. J Orthop Res. 12:789–795.10.1002/jor.v12:6
- Freeman MAR, Pinskerova V. 2005. The movement of the normal tibio-femoral joint. J Biomech. 38:197–208.10.1016/j.jbiomech.2004.02.006
- Grip H, Häger C. 2013. A new approach to measure functional stability of the knee based on changes in knee axis orientation. J Biomech. 46:855–862.10.1016/j.jbiomech.2012.12.015
- Grood ES, Suntay WJ. 1983. A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. J Biomech Eng. 105:136–144.10.1115/1.3138397
- Iwaki H, Pinskerova V, Freeman MAR. 2000. Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Jt Surg. 82:1189–1195.10.1302/0301-620X.82B8.10717
- Jonsson H, Kärrholm J. 1994. Three-dimensional knee joint movements during a step-up: Evaluation after anterior cruciate ligament rupture. J Orthop Res. 12:769–779.10.1002/jor.v12:6
- Kessler O, Durselen L, Banks S, Mannel H, Marin F. 2007. Sagittal curvature of total knee replacements predicts in vivo kinematics. Clin Biomech. 22:52–58.10.1016/j.clinbiomech.2006.07.011
- Küpper JC, Robu I, Frayne R, Ronsky JL. 2013. The knee loading apparatus: axial, anterior, and compressive loading with magnetic resonance imaging. J Mech Des. 135:024501.10.1115/1.4023152
- Morishige M, McQueen DA, Chong A, Ballard GP, Cooke FW. 2010. The influence of sequential debridement in total knee arthroplasty on the flexion axis of the knee using computer-aided navigation. J Orthop Res. 28:767–772.
- Peters A, Galna B, Sangeux M, Morris M, Baker R. 2010. Quantification of soft tissue artifact in lower limb human motion analysis: A systematic review. Gait & Posture. 31(1):1–8.10.1016/j.gaitpost.2009.09.004
- Sakane M, Livesay GA, Fox RJ, Rudy TW, Runco TJ, Woo SL-Y. 1999. Relative contribution of the ACL, MCL, and bony contact to the anterior stability of the knee. Knee surgery, Sport Traumatol Arthrosc. 7:93–97.10.1007/s001670050128
- Sheehan FT. 2007. The finite helical axis of the knee joint (a non-invasive in vivo study using fast-PC MRI). J Biomech. 40:1038–1047.10.1016/j.jbiomech.2006.04.006
- Shiavi R, Limbird T, Frazer M, Stivers K, Strauss A, Abramovtiz J. 1987. Helical motion analysis of the knee – I. Methodology for studying kinematics during locomotion. J Biomech. 20:459–469.10.1016/0021-9290(87)90247-8
- Soderkvist I, Wedin P. 1993. Determining the movements of the skeleton using well-configured markers. J Biomech. 26:1473–1477.10.1016/0021-9290(93)90098-Y
- Spoor CW, Veldpaus FE. 1980. Rigid body motion calculated from spatial co-ordinates of markers. J Biomech. 13:391–393.10.1016/0021-9290(80)90020-2
- Van den Bogert A, Read L, Nigg BM. 1996. A method for inverse dynamic analysis using accelerometry. J Biomech. 29:949–954.10.1016/0021-9290(95)00155-7
- Van den Bogert AJ, Reinshmidt C, Lundberg A. 2008. Helical axes of skeletal knee joint motion during running. J Biomech. 41:1632–1638.10.1016/j.jbiomech.2008.03.018
- Westphal CJ, Schmitz A, Reeder SB, Thelen DG. 2013. Load-dependent variations in knee kinematics measured with dynamic MRI. J Biomech. 46:2045–2052.10.1016/j.jbiomech.2013.05.027
- Woltring HJ, Huiskes R, de Lange A, Veldpaus FE. 1985. Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech. 18:379–389.10.1016/0021-9290(85)90293-3