269
Views
0
CrossRef citations to date
0
Altmetric
Research Article

Biomechanical evaluation of a novel mandibular distraction osteogenesis protocol: an in-vitro validation and the practical use of the method

ORCID Icon, &
Pages 765-776 | Received 09 Sep 2020, Accepted 10 Nov 2020, Published online: 26 Nov 2020

References

  • Brasileiro BF, Grempel RG, Ambrosano GMB, Passeri LA. 2009. An in vitro evaluation of rigid internal fixation techniques for sagittal split ramus osteotomies: advancement surgery. J Oral Maxillofac Surg. 67(4):809–817.
  • Breik O, Tivey D, Umapathysivam K, Anderson P. 2016. Mandibular distraction osteogenesis for the management of upper airway obstruction in children with micrognathia: a systematic review. Int J Oral Maxillofac Surg. 45(6):769–782.
  • Chang Y, Tambe AA, Maeda Y, Wada M, Gonda T. 2018. Finite element analysis of dental implants with validation: to what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process. Int J Implant Dent. 4(1):7
  • Gassmann CJ, Van Sickels JE, Thrash WJ. 1990. Causes, location, and timing of relapse following rigid fixation after mandibular advancement. J Oral Maxillofac Surg. 48(5):450–454.
  • Gladilin E, Ivanov A. 2009. Computational modelling and optimisation of soft tissue outcome in cranio-maxillofacial surgery planning. Comput Methods Biomech Biomed Eng. 12(3):305–318.
  • Hadi G, Karine B-G, Yves C, Pierre L. 2010. Stability of osteosynthesis with bicortical screws placed in a triangular shape in mandibular sagittal split 5 mm advancement osteotomy: biomechanical tests. Br J Oral Maxillofac Surg. 48(8):624–628.
  • Kocaoğlu M, Eralp L, Sen C, Cakmak M, Dincyürek H, Göksan SB. 2003. Management of stiff hypertrophic nonunions by distraction osteogenesis: a report of 16 cases. J Orthop Trauma. 17(8):543–548.
  • Kraeima J, Glas HH, Witjes MJH, Schepman KP. 2018. Patient-specific pre-contouring of osteosynthesis plates for mandibular reconstruction: using a three-dimensional key printed solution. J Craniomaxillofac Surg. 46(6):1037–1040.
  • Lam DJ, Tabangin ME, Shikary TA, Uribe-Rivera A, Meinzen-Derr JK, de Alarcon A, Billmire DA, Gordon CB. 2014. Outcomes of mandibular distraction osteogenesis in the treatment of severe micrognathia. JAMA Otolaryngol Head Neck Surg. 140(4):338.
  • Mobarak KA, Espeland L, Krogstad O, Lyberg T. 2001. Mandibular advancement surgery in high-angle and low-angle class II patients: different long-term skeletal responses. Am J Orthod Dentofacial Orthop. 119(4):368–381.
  • Morneburg TR, Pröschel PA. 2002. Measurement of masticatory forces and implant loads: a methodologic clinical study. Int J Prosthodont. 15(1):20–27.
  • Olszewski R. 2012. Surgical engineering in cranio-maxillofacial surgery: a literature review. J Healthc Eng. 3(1):53–86.
  • Ouyang H, Deng Y, Xie P, Yang Y, Jiang B, Zeng C, Huang W. 2017. Biomechanical comparison of conventional and optimised locking plates for the fixation of intraarticular calcaneal fractures: a finite element analysis. Comput Methods Biomech Biomed Eng. 20(12):1339–1349.
  • Ramos A, Duarte RJ, Mesnard M. 2015. Prediction at long-term condyle screw fixation of temporomandibular joint implant: a numerical study. J Craniomaxillofac Surg. 43(4):469–474.
  • Ribeiro PD, et al. 2012. Which kind of miniplate to use in mandibular sagittal split osteotomy? An in vitro study. Int J Oral Maxillofac Surg. 41(11):1369–1373.
  • Robinson D, Aguilar L, Gatti A, Abduo J, Lee PVS, Ackland D. 2019. Load response of the natural tooth and dental implant: a comparative biomechanics study. J Adv Prosthodont. 11(3):169–178.
  • Schreuder WH, Jansma J, Bierman MWJ, Vissink A. 2007. Distraction osteogenesis versus bilateral sagittal split osteotomy for advancement of the retrognathic mandible: a review of the literature. Int J Oral Maxillofac Surg. 36(2):103–110.
  • Sener I, Arıcı S, Bereket C, Tek M. 2012. In vitro biomechanical evaluation of modified plating techniques for bilateral sagittal split ramus osteotomy in mandibular advancement. J Craniofac Surg. 23(5):1573–1576.
  • Şensoy AT, Kaymaz I, Ertaş Ü. 2020. Development of particle swarm and topology optimization-based modeling for mandibular distractor plates. Swarm Evol Comput. 53:100645.
  • Sensoy AT, Kaymaz I, Ertaş Ü, Kiki A. 2018. Determining the patient-specific optimum osteotomy line for severe mandibular retrognathia patients. J Craniofac Surg. 29(5):e449–e454.
  • Shimura Y, Sato Y, Kitagawa N, Omori M. 2016. Biomechanical effects of offset placement of dental implants in the edentulous posterior mandible. Int J Implant Dent. 2(1):17–17.
  • Sigua-Rodriguez EA, Caldas RA, Goulart DR, Hemerson de Moraes P, Olate S, Ricardo Barão VA, Ricardo de Albergaria-Barbosa J. 2019. Comparative evaluation of different fixation techniques for sagittal split ramus osteotomy in 10 mm advancements. Part two: Finite element analysis. J Craniomaxillofac Surg. 47(7):1015–1019.
  • Simmons KE, Turvey TA, Phillips C, Proffit WR. 1992. Surgical-orthodontic correction of mandibular deficiency: five-year follow-up. Int J Adult Orthodon Orthognath Surg. 7(2):67–79.
  • Strijen P, Breuning KH, Becking AG, Tuinzing DB. 2004. Stability after distraction osteogenesis to lengthen the mandible: results in 50 patients. J Oral Maxillofac Surg. 62(3):304–307.
  • van Strijen PJ, Breuning KH, Becking AG, Perdijk FBT, Tuinzing DB. 2003. Complications in bilateral mandibular distraction osteogenesis using internal devices. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 96(4):392–397.
  • van Strijen PJ, Breuning KH, Becking AG, Tuinzing DB. 2004. Stability after distraction osteogenesis to lengthen the mandible: results in 50 patients. J Oral Maxillofac Surg. 62(3):304–307.
  • Yang W-F, Choi WS, Leung YY, Curtin JP, Du R, Zhang C-Y, Chen X-S, Su Y-X. 2018. Three-dimensional printing of patient-specific surgical plates in head and neck reconstruction: a prospective pilot study. Oral Oncol. 78:31–36.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.