References
- Woo , R. Y. G. and Morrey , B. F. ( 1982 ). Dislocations After Total Hip Arthroplasty . JBJS , 64A ( 9 ), 1295 – 1306 .
- Grigoris , P. , Grecula , M. J. and Amstutz , H. C. ( 1994 ). Tripolar Hip Replacement for Recurrent Prosthetic Dislocation . Clin Orth and Rel Res. 304 , 148 – 155 .
- Coventry , M. B. ( 1985 ). Late Dislocations in Patients With Charnley Total Hip Arthroplasty . JBJS , 67A ( 6 ), 833 – 841 .
- Morrey , B. F. ( 1992 ). Instability After Total Hip Arthroplasty . Orth Clin North America , V23 ( 2 ), 237 – 247 .
- Amstutz , H. C. , Lodwig , R. M. , Schurman , D. J. and Hodgson , A. G. ( 1975 ). Range of Motion Studies for Total Hip Replacements A Comparative Study With a New Experimental Apparatus . Clin Orth and Rel Res. , 111 , 124 – 130 .
- Chandler , D. R. , Glousman , R. , Hull , D. , McGuire , P. J. , Kim , I. S. , Clarke , I. C. and Sarmiento , A. ( 1982 ). Prosthetic Hip Range of Motion and Impingement The Effects of Head and Neck Geometry . Clin Orth and Rel Res , 166 , 284 – 291 .
- Robinson , R. P. , Simonian , P. T. , Gradisar , I. M. and Ching , R. P. ( 1997 ). Joint Motion and Surface Contact Area Related to Component Position in Total Hip Arthroplasty . JBJS , 64A ( 9 ). 140 – 146 .
- Nicholas , R. M. , Orr , J. F. , Mollan , R. A. B. , Calder-wood , J. W. , Nixon , J. R. and Watson , P. ( 1990 ). Dislocation of Total Hip Replacements A Comparative Study of Standard, Long Posterior Wall, and Augmented Acetabular Components . JBJS , 72B , 418 – 422 .
- Murray , D. W. ( 1992 ). Impingement and Loosening of the Long Posterior Wall Acetabular Implant . JBJS , 74B ( 3 ), 377 – 379 .
- Maxian , T. A. , Brown , T. D. , Pedersen , D. R. and Callag-han , J. J. ( 1996 ). A Sliding-Distance-Coupled Finite Element Formulation for Polyethylene Wear in Total Hip Arthroplasty . J. Biomech , 29 , 687 – 692 .
- Cripton , P. A. ( 1993 ). Compressive Characterization of Ultra High Molecular Weight Polyethylene With Applications to Contact Stress Analysis of Total Knee Replacements . M.Sc. Thesis . Queen's University at Kingston, Dept. of Mechanical Engineering .
- Kurtz , S. ( 1995 ). The Effects of Degradation on the Properties, Stresses, and Strains in Ultra High Molecular Weight Polyethylene Components for Total Hip and Total Knee Replacements . Ph.D. Thesis , Cornell University .
- Hall , R. M. and Unsworth , A. ( 1997 ). “ Friction in Hip Pros-Theses ”, Biomaterials 18 . 1017 – 1026 .
- Hashemi , A. , Dammak , M. , Shirazi-Adl , A. and Zutor , D. J. ( 1997 ). Friction Properties at Polyethylene-Metal Interfaces in Total Joint Arthroplasty , Advances in Bioengineering. ASME BED . 36 , 315 .