- Spenger , J. D. and Sexton , K. 1983 . Indoor Air Pollution: A Public Health Perspective . Science , 221 ( 4605 ) : 9 – 17 .
- Sundell , J. 1996 . What We Know, and Don't Know about Sick Building Syndrome . ASHRAE J. , 38 ( 6 ) : 51 – 57 .
- Hedge , A. 1996 . Predicting Sick Building Syndrome at the Individual and Aggregate Levels . Environ. Int. , 22 ( 1 ) : 3 – 19 .
- 1989 . ASHRAE Standard 62-89: Ventilation for Acceptable Indoor Air Quality , 6A Atlanta : American Society of Heating, Refrigerating and Air Conditioning Engineers .
- Chow , W. K. , Fung , W. Y. and Wong , L. T. 2002 . Preliminary Studies on a New Method for Assessing Ventilation in Large Spaces . Building and Environment , 37 ( 2 ) : 145 – 152 .
- Patankar , S. V. 1980 . Numerical Heat Transfer and Fluid Flow , Washington, DC : Hemisphere .
- Brohus , H. and Nielsen , P. V. 1994 . “ Contaminant Distribution around Persons in Rooms Ventilated by Displacement Ventilation ” . In Roomvent'94 , 294 – 312 . Poland : Krakow .
- Hyun , S. and Kleinstreuer , C. 2001 . Numerical Simulation of Mixed Convection Heat and Mass Transfer in a Human Inhalation Test Chamber . Int. J. Heat Mass Transfer , 44 : 2247 – 2260 .
- Yang , X. , Chen , Q. , Zhang , J. S. , Magee , R. , Zeng , J. and Shaw , C. Y. 2001 . Numerical Simulation of VOC Emissions from Dry Materials . Building and Environment , 36 : 1099 – 1107 .
- 1986 . CIBSE Guide: Installation and Equipment Data , London, , UK : CIBSE .
- Murakami , S. New Scales for Ventilation Efficiency and Their Application Based on Numerical Simulation of Room Airflow . Int. Symp. on Room Air Convection and Ventilation Effectiveness . July 22–24 , Tokyo, Japan. pp. 22 – 38 .
- Tatsuya , H. , Ishizub , Y. , Kato , S. and Murakami , S. 2002 . CFD Analysis on Characteristics of Contaminated Indoor Air Ventilation and Its Application in the Evaluation of the Effects of Contaminant Inhalation by a Human Occupant . Building and Environment , 37 : 219 – 230 .
- Waters , J. R. and Simon , M. W. 2000 . “ The Effect of Recirculation on Ventilation Effectiveness Parameters ” . In Roomvent' 2000 913 – 918 . Reading, , UK
- Chen , Q. 1995 . Comparison of Different Models for Indoor Airflow Computation . Numer. Heat Transfer B , 28 : 353 – 369 .
- Li , X. , Li , D. and Dou , C. 2003 . An Algorithm for Calculating Fresh Air Age in Central Ventilation System . Science in China (Ser. E) , 46 ( 2 ) : 182 – 190 .
- Li , X. , Wang , X. , Li , X. and Li , Y. Investigation on the Relationship between Flow Pattern and Air Age . Proc. Sixth Int. IBPSA Conf. Kyoto, Japan. pp. 423 – 429 .
- Zhao , B. , Li , X. , Yan , Q. and Simplified , A . 2003 . System for Indoor Airflow Simulation . Building and Environment , 38 : 543 – 552 .