References
- Falck , K. , Grohon , P. Sorsa , M. 1979 . Mutagenicity in Urine of Nurses Handling Cytostatic Drugs . Lancet , : 1250
- Nguyen , T. V. , Thiess , J. C. and Matney , T. S. 1982 . Exposure of Pharmacy Personnel to Mutagenic Antineoplastic Drugs . Can. Res. , 42 : 4792
- Nikula , E. , Kivinitty , K. , Leisti , J. and Taskinen , P. J. 1984 . Chromosome Aberrations in Lymphocytes of Nurses Handling Cytostatic Agents . Scand. J. Work Environ. Health , 10 : 71
- Norppa , H. , Sorsa , M. Vainio , H. 1980 . Increased Sister Chromatid Exchange Frequencies in Lymphocytes of Nurses Handling Cytostatic Drugs . Scand. J. Work Environ. Health , 6 : 299
- Hirst , M. , Tse , S. , Mills , D. G. and Levin , L. 1984 . Occupational Exposure to Cyclophosphamide . Lancet , : 186
- Sorsa , M. , Hemminiki , K. and Vainio , H. 1985 . Occupational Exposure to Anticancer Drugs—Potential and Real Hazards . Mut. Res. , 154 : 135
- Laidlaw , J. L. , Connor , T. H. Theiss , J. C. 1984 . Permeability of Latex and Polyvinyl Chloride Gloves to 20 Antineoplastic Drugs . Am. J. Hosp. Pharm. , 41 : 2618
- Thomsen , K. and Mikkelsen , H. I. 1975 . Protective Capacity of Gloves Used for Handling of Nitrogen Mustard . Contact Derm. , 1 : 268
- Connor , T. H. , Laidlaw , J. L. Theiss , J. C. 1984 . Permeability of Latex and Polyvinyl Chloride Gloves to Carmustine . Am. J. Hosp. Pharm. , 41 : 676
- Bang , G. S. 1984 . Permeation of Sodium Pentachorphenate Solutions through Selected Glove Materials , Seattle, WA : University of Washington . Master's Thesis
- Franz , T. J. 1975 . Percutaneous Absorption on the Relevance of In Vitro Data . J. Invest. Derm. , 64 : 190
- Franz , T. J. 1978 . The Finite Dose Technique as a Valid In Vitro Model for the Study of Percutaneous Absorption in Man . Curr. Probl. Dermatol. , 7 : 58
- American Society for Testing and Materials . 1981 . Standard Test Method for Resistance of Protective Clothing Materials to Permeation by Hazardous Liquid Chemicals , Philadelphia : ASTM . ASTM F739–81
- Slevin , M. L. , Ang , L. M. , Johnston , A. and Turner , P. 1984 . The Efficiency of Protective Gloves Used in the Handling of Cytotoxic Drugs . Cancer Chemother. Pharmacol. , 12 : 151
- Silkowski , J. B. , Hortsman , S. W. and Morgan , M. S. 1984 . Permeation through Five Commercially Available Glove Materials by Two Pentachlorophenol Formulations . Am. Ind. Hyg. Assoc. J. , 45 ( 8 ) : 501
- Crank , J. and Park , G. S. 1968 . Diffusion in Polymers , New York : Academic Press .
- Sansone , E. B. and Jonas , L. A. 1981 . Resistance of Protective Clothing Materials to Permeation by Solvent “Splash” . Environ. Res. , 26 : 340
- Vaughn , M. and Christensen , W. 1985 . Occupational Exposure to Cancer Chemotherapeutic Drugs: A Literature Review . Am. Ind. Hyg. Assoc. J. , 46 : B8
- Occupational Safety and Health Administration . 1986 . Work Practice Guidelines for Personnel Dealing with Cytotoxic (Antineoplastic) Drugs , Washington, DC : OSHA . OSHA Instruction Publication 8–1.1
- Anderson , R. W. , Puckett , W. H. Dana , W. J. 1981 . Risk of Handling Injectable Antineoplastic Agents . Am. J. Hosp. Pharm. , 39 : 1881
- Bledsoe , L. 1983 . Antineoplastic Agents: Management of Health Risks for the I.V. Nurse . NITA , 6 : 332
- Hoffman , D. M. November 1983 . Handling Antineoplastic Agents , November , Wayne, NJ : Lederle Laboratories .