References
- Diffusive Sampling. An Alternative Approach to Workplace Monitoring . the Proceedings of an international symposium held in Luxembourg . September 22–26 1986 . Edited by: Berlin , A. , Brown , R. H. and Saunders , K. J. London : Royal Society of Chemistry .
- Harper , M. and Purnell , C. J. 1987 . Diffusive Sampling—A Review . Am. Ind. Hyg. Assoc. J , 48 : 214 – 218 .
- Rose , V. E. and Perkins , J. L. 1982 . Passive Dosimetry—State of the Art Review . Am. Ind. Hyg. Assoc. J , 43 ( 8 ) : 605 – 621 .
- Van der Hoed , N. , van Asselen , O. L. J. and van Dongen , J. P. C. M. 1987 . Replicate Side-by-Side Field Comparison of 3M Diffusive Samplers Versus Charcoal Tube Samplers for Styrene . Am. Ind. Hyg. Assoc. J , 48 : 252 – 256 .
- Björset , O. , Borresen , E. and Malvik , B. 1982 . Comparison of Passive Dosimeters and Charcoal Tubes for Styrene and Acetone . Ber. Int. Kolloq. Verhuetung Arbeitsunfällen Berufskr. Chem. Ind , 8 : 389 – 398 .
- Bartolucci , G. B. , Perbellini , L. Gori , G. P. 1986 . Occupational Exposure to Solvents: Field Comparison of Active and Passive Samplers and Biological Monitoring of Exposed Workers . Ann. Occup. Hyg , 30 : 295 – 306 .
- Samimi , B. and Falbo , L. 1985 . Comparison of Standard Charcoal Tubes with Abcor (NMS) Gas Badges within Controlled Atmosphere . Am. Ind. Hyg. Assoc. J , 46 : 49 – 52 .
- van der Wal , J. F. and Moerkerken , A. 1984 . The Performance of Passive Diffusion Monitors for Organic Vapors for Personal Sampling of Painters . Ann. Occup. Hyg , 28 ( 1 ) : 39 – 47 .
- Evans , P. R. and Horstman , S. W. 1981 . Desorption Efficiency Determination Methods for Styrene Using Charcoal Tubes and Passive Monitors . Am. Ind. Hyg. Assoc. J , 42 : 471 – 474 .
- Malek , R. F. , Daisey , J. M. and Cohen , B. S. 1986 . The Effect of Aerosol on Estimates of Inhalation Exposure to Airborne Styrene . Am. Ind. Hyg. Assoc. J , 47 : 524 – 529 .
- Taylor , D. G. , Kupel , R. E. and Bryant , J. M. , eds. 1977 . “ National Institute for Occupational Safety and Health Backup Data Report No. S30 ” . In Documentation of the NIOSH Validation Tests , S30–1 – S30–3 . Cincinnati, OH : NIOSH .
- den Ouden , H. P. L. 1958 . Het meten van luchtsnelheden (The Measurement of Air Velocities) , The Netherlands : Department of Indoor Environment . Report No. 27. IG/TNO
- De Nationale MAC-lijst 1986(The Dutch TLV list 1986) , Voorburg, , The Netherlands : Directoraat-Generaal van de Arbeid van het Ministerie van Sociale zaken en Werkgelegenheid . Arbeidsinspectie P 145
- 1986 . 3M: Technische Information 3M monitor. 3M Monitor für organische Gase und Dampfe—3500 , Neuss, FRG : 3M Deutschland, GmbH, Abteilung Technik Arbeitzschutz–Produkten .
- Bland , J. M. and Altman , D. G. 1986 . Statistical Methods for Assessing Agreement Between Two Methods of Clinical Measurements . Lancet , February 8 : 307 – 310 .
- Kring , E. V. , Ansul , G. R. Henry , T. J. 1984 . Evaluation of the Standard NIOSH-Type Charcoal Tube Sampling Method for Organic Vapors in Air . Am. Ind. Hyg. Assoc. J , 45 : 250 – 259 .
- Brown , R. H. , Harvey , R. P. , Purnell , C. J. and Saunders , K. J. 1984 . A Diffusive Sampler Evaluation Protocol . Am. Ind. Hyg. Assoc. J , 45 ( 2 ) : 67 – 75 .
- Berlin , A. , Brown , R. H. Leichnitz , K. 1988 . Diffusive Sampling—An Alternative Approach . Appl. Ind. Hyg , 3 ( 2 ) : R2 – R6 .