References
- Airflow around Buildings. In ASHRAE Handbook—1997 Fundamentals; American Society of Heating, Refrigerating, and Air-Conditioning Engineers Inc.: Atlanta, GA, 1997; Chapter 15.
- Halitsky, J. Gas Diffusion Near Buildings; ASHRAE Transact. 1963, 69, 464-484.
- Wilson, D.J.; Chui, E. Influence of Exhaust Velocity and Wind Incidence Angle on Dilution from Roof Vents; ASHRAE Transact. 1985, 91 (2B), 1693-1706.
- Wilson, D.J.; Chui, E. Effect of Turbulence from Upwind Buildings on Dilution of Exhaust Gases; ASHRAE Transact. 1987, 93 (2), 2186-2197.
- Wilson, D.J.; Lamb, B. Dispersion of Exhaust Gases from Roof-Level Stacks and Vents on a Laboratory Building; Atmos. Environ. 1994, 28, 3099-3111.
- Petersen, R.L.; Wilson, D.J. Analytical Versus Wind Tunnel Determined Concentrations Due to Laboratory Exhaust; ASHRAE Transact. 1989, 95 (2), 729-736.
- Perera, M.D.; Tull, R.G.; White, M.K.; Walker, R.R. Assessing Intake Contamination from Atmospheric Dispersion of Building Exhaust. In Proceedings of 12th AIVC Conference, Ottawa, Ontario, Canada, 1991; pp 347-357.
- Schuyler, G.D.; Turner, G.G. Comparison of Wind Tunnel Test Results with Empirical Exhaust Dilution Factors; ASHRAE Transact. 1989, 95 (2), 729-736.
- Lam, K.S.; Kot, S.C.; Fung, K.W.; Ma, R.Y.P. A Field Evaluation of Rooftop Dispersion Formula in Urban Center; J. WindEngr. Indust. Aerodyn. 1985, 21, 295-305.
- Lam, K.S.; Kot, S.C. Field Study of Rooftop Dispersion in an Urban Area. In Proceedings of the 3rd Asia-Pacific Symposium on Wind Engineering, Hong Kong, December 13-15, 1992; pp 999-1004.
- Georgakis, K.; Smith, J.; Goodfellow, H.; Pye, J. Review and Evaluation of Models Estimating the Minimum Atmospheric Dilution of Gases Exhausted Near Buildings; J. Air & Waste Manage. Assoc. 1995, 45, 722-729.
- Lamb, B.; Cronn, D. Fume Hood Exhaust Reentry into a Chemistry Building; J. Am. Ind. Hyg. Assoc. 1986, 47 (2), 115-123.
- Saathoff, P.; Stathopoulos, T. Dispersion of Exhaust Gases from Roof-Level Stacks on a Laboratory Building—Discussion; Atmos. Environ. 1997, 32 (10), 1679-1089.
- Stathopoulos, T.; Lazure, L.; Saathoff, P. Tracer Gas Investigation of Reingestion of Building Exhaust in an Urban Environment; Rapport de recherche R-213, Série études et recherche; IRSST: Montréal, Québec, Canada, 1999.
- Halitsky, J. Calculation of Minimum Available Atmospheric Dilution Downwind of Building Exhausts; ASHRAE Transact. 1990, 96, 46-51.
- Chui, E.H.; Wilson, D.J. Effects of Varying Wind Direction on Exhaust Gas Dilution, J. Wind Engr. Ind. Aerodyn. 1988, 31, 87-104.
- Wilson, D.J.; Fabris, I.C.; Chen, J.; Ackerman, M.Y. Adjacent Building Effects on Laboratory Fume Hood Exhaust Stack Design; ASHRAE Research Project 897; American Society of Heating, Refrigerating, and Air Conditioning Engineers Inc.: Atlanta, GA, 1998.