References
- Marple, V.A. Ph.D. Dissertation, University of Minnesota, Minneapolis,MN, September 1970.
- Marple, V.A.; Liu, B.Y.H. Characteristics of Laminar Jet Impactors;Environ. Sci. Technol. 1974, 8, 648-654.
- Marple, V.A.; Willeke, K. Impactor Design; Atmos. Environ. 1976, 10,891-896.
- Rader, D.J.; Marple, V.A. Effect of Ultra-Stokesian Drag and Particle Interception on Impaction Characteristics; Aerosol Sci. Technol. 1985, 4, 141-156.
- Marple, V.A. History of Impactors-the First 110 Years; Aerosol Sci.Technol. 2004, 38, 247-292.
- Huang, C.H.; Tsai, C.J. Effect of Gravity on Particle Collection Efficiency of Inertial Impactors; J. Aerosol Sci. 2001, 32, 375-387.
- Huang, C.H.; Tsai, C.J. Influence of Impaction Plate Diameter and Particle Density on the Collection Efficiency of Round-Nozzle Inertial Impactors; Aerosol Sci. Technol. 2002, 36, 714–720.
- Marple, V.A.; Olson, B.A.; Miller, N.C. A Low-Loss Cascade Impactor with Stage Collection Cups: Calibration and Pharmaceutical Inhaler Applications; Aerosol Sci. Technol. 1995, 22, 124-134.
- Marple, V.A.; Olson, B.A.; Miller, N.C. The Role of Inertial Particle Collectors in Evaluating Pharmaceutical Aerosol Delivery Systems; J. Aerosol Med. 1998, 11, 139-153.
- Vaughan, N.P. The Andersen Impactor: Calibration, Wall Losses and Numerical Simulation; J. Aerosol Sci. 1989, 20, 67-90.
- Mitchell, J.P.; Nagel, M.W. Cascade Impactors for the Size Characterization of Aerosols from Medical Inhalers: Their Uses and Limitations; J. Aerosol Med. 2003, 16, 341-377.
- Weda, M.; Zanen, P.; de Boer, A.H.; Barends, D.M.; Frijlink, H.W. An Investigation into the Predictive Value of Cascade Impactor Results for Side Effects of Inhaled Salbutamol; Int. J. Pharmaceut. 2004, 287 79-87.
- Rubow, K.L.; Marple, V.A.; Olin, J.; Mccawley, M.A. A Personal Cascade Impactor: Design, Evaluation and Calibration; Am. Ind. Hygiene Assoc. J. 1987, 48, 532-538.
- Rader, D.J.; Marple, V.A. Effect of Particle Gravitational Forces on the Calculation of Impactor Efficiency Curves; In Aerosols; Liu, B. Y. H.; Pui, D. Y. H.; Fissan, W. J., Eds.; Elsevier: New York, NY, 1984; pp 123-126.
- Marple, V.A.; Roberts, D.L.; Romay, F.J.; Miller, N.C.; Truman, K.G.;Oort, M.V.; Olsson, B.; Holroyd, M.J.; Mitchell, J.P.; Hochrainer, D. Next Generation Pharmaceutical Impactor (A New Impactor for Pharmeceutical Inhaler Testing)—Part I: Design. J. Aerosol Med. 2003, 16, 283-299.
- Marple, V.A.; Olson, B.A.; Santhanakrishnan, K.; Mitchell, J.P.; Murray, S.C.; Hudson-Curtis, B.L. Next Generation Pharmaceutical Impactor (A New Impactor for Pharmeceutical Inhaler Testing)—Part II: Archival Calibration. J. Aerosol Med. 2003, 16, 301-324.
- Marple, V.A.; Olson, B.A.; Santhanakrishnan, K.; Roberts, D.L.; Mitchell, J.P.; Hudson-Curtis, B.L. Next Generation Pharmaceutical Impactor (A New Impactor for Pharmeceutical Inhaler Testing)—Part III: Extension of Archival Calibration to 15 L/min; J. Aerosol Med. 2004, 17, 335-343.
- Patankar, S.V. Numerical Heat Transfer and Fluid Flow; Hemisphere: Washington, DC, 1980.
- Hinds, W.C. Aerosol Technology; John Wiley & Sons: New York, NY, 1999.
- Marple, V.A.; Rubow, K.L.; Turner, W.; Spengler, J.D. Low Flow Rate Sharp Cut Impactors for Indoor Air Sampling: Design and Calibration; J. Air Pollut. Control Assoc. 1987, 37, 1303-1307.