References
- VDI 3882.1-Olfactometry-Determination of Odor Intensity; Verein Deutscher Ingenieure: Düsseldorf, Germany, 1992.
- VDI 3940 Part 1, Determination of Odorants in Ambient Air by Field Inspections—Determination of the Frequency of Identifiable Odour in Ambient Air-Grid Measurement; Verein Deutscher Ingenieure: Düsseldorf, Germany, 2003.
- Verein Deutscher Ingenieure. VDI 3940 Part 2, 2, Determination of Odorants in Ambient Air by Field Inspections—Determination of the Frequency of Identifiable Odour in Ambient Air-Plume Measurement; Verein Deutscher Ingenieure: Düsseldorf, Germany, 2003.
- Guidance for the Assessment of Environmental Factors-Assessment of Odour Impacts from New Proposals No 47; Environmental Protection Authority: Western Australia, 2002.
- Jiang, J.; Sands, J. Report on Odour Emissions from Poultry Farms in Western Australia, Principal Technical Report; Centre for Water and Waste Technology, University of New South Wales: Sydney, Australia, 1998; Available at http://www.environ.wa.gov.au/pubs/ (accessed 2006).
- Jiang, J.; Sands, J. Report on Odour Emissions from Poultry Farms in Western Australia, Supplementary Technical Report; Centre for Water and Waste Technology, University of New South Wales: Sydney, Australia, 1998; Available at http://www.environ.wa.gov.au/pubs/ (accessed 2006).
- Jiang, J. Development of Odour Impact Criteria Using Odour Intensity Measurement and Community Survey. Presented at 2nd International Conference on Air Pollution from Agricultural Operations, Des Moines, IA, October 2000.
- Jiang, J. Development of Odour Impact Criteria for the Australian Pig Industry; Prepared for Australian Pork Limited, The University of New South Wales: Sydney, Australia, 2001.
- EnvironOdour Web site. Available at http://www.environodour.com.au/ (accessed 2004).
- Jiang, J. Development of the Next Generation Olfactometer-Dyna-scent, Odour Management Review; Ministry of the Environment: Japan, Beppu City, 2002.
- Seinfeld. J. Atmospheric Chemistry and Physics of Air Pollution; John Wiley & Sons, Inc.: New York, 1998.
- Amos, T.; Hyman, Odour Measurement and Control. In Patty’s Industrial Hygiene and Toxicology 3rd rev. ed.; Clayton, G.D.; Clayton, F.E., Eds.; Wiley-Interscience: New York, 1982; pp 665-705.
- Chen, Y.; Bundy, D.; Hoff S. Development of the Relationship Between Odor Intensity and Threshold Dilution Ratio for Swine Units; J. Air & Waste Manage. Assoc. 1999, 49, 1082–1088
- Nicolai, R.E.; Clanton, C.J.; Guo, H. Modeling the Relationship Between Detection Threshold and Intensity of Swine Odours. In Proceedings of the Second International Conference: Air Pollution from Agricultural Operations, American Society of Agricultural Engineers: St. Joseph, MI, 2000; pp 296-304.
- Schulz, T.; Balch, A.; Bowly, S. Odour Intensity Measurement: An Overview of Its Potential for Use in Odour Impact Assessment and Control; Clean Air Environ. Qual. 2002, 36, 38-41.
- Standard prEN 13725, Air Quality-Determination of Odour Concentration by Dynamic Olfactometry; Comitté Européen de Normalisation: Brussels, Belgium, 2001.
- AS/NZS 4323.3:2001 Stationary Source Emissions-Part 3: Determination of Odour Concentration by Dynamic Olfactometry. Standards Australia: Sydney, Australia, 2001.
- van Harreveld, A.P.; Heeres, P.; Harssema, H. A Review of 20 Years of Standardization of Odor Concentration Measurement by Dynamic Olfactometry in Europe, J. Air & Waste Manage. Assoc. 1999, 49, 705-715.
- Bardsley, T.; Demetriou, J. Interlaboratory Odour Study Conducted With EPA Approved Method; Publication sr2; Victoria Environment Protection Agency: Melbourne, Australia, 2003.
- Schulz, T. Response to CASANZ on David Pitt’s Criticism of Modified VDI 3882 Intensity Testing Method; Available at http://www.casanz.org.au/ (accessed 2003).
- Pitt, D. Letter to the Editor. Clean Air Environ. Qual. 2003, 37, 8-10.
- Jiang, J.; Coffey, P.; Toohey, B., Odour Intensity Measurement for Wastewater and Alumina Industries; Presented at 17th International Clean Air & Environment Conference, Hobart, Australia, May 3-6, 2005.
- Jiang, J. Use of Odour Intensity in Impact Assessment; Presented at National Workshop on Odour Assessment for Piggeries, Mascot, Australia, November 13-14, 2002.