References
- Raju NK. Prestressed concrete. 5th ed. New Delhi: Tata McGraw hill education private limited; 2012. p. 1–15.
- Dean WE. Prestressed concrete difficulties overcome in Florida bridge practice. Civ Eng. 1957 June;27:404–408.
- Abeles PW. An Introduction to prestressed concrete. Vol. 2. London: Concrete publication limited; 1965. p. 552–556.
- Woodward RJ. Collapse of a segmental post-tensioned concrete bridge. Transportation research record 1211. Crowthorne, Berkshire, England: Transport and road research laboratory. p. 38–59.
- Proverbio E, Bonaccorsi LM. Failure of prestressing steel induced by crevice corrosion in prestressed concrete structures. 9th International conference on durability of building materials and components; 2002 Mar; Australia.
- Beitler S, Concord NC Walkway collapses. May 2000 [Accessed 2018 Aug 29]. Available from: http://www.gendisasters.com/north-carolina/23434/concord-nc-walkway-collapses-may-2000
- Bureau of Indian standards, Indian standard code of practice for prestressed concrete. Reaffirmed 2004. (IS: 1343-1980).
- Ministry of road transport & highway (MORTH). Specifications for road and bridge works. New Delhi: Indian roads congress; 2013.
- IRC: 112:2011. Code of practice for concrete road bridges. New Delhi: Indian roads congress; 2011.
- Standard specifications for road and bridge construction. Florida department of transportation; 2013.
- Prestress manual. State of California department of transportation; 2005.
- Grouting of bridge post-tensioning tendons: training manual. State of Florida department of transportation; 2002.
- Somerville G. Grouting of post - tensioning tendons. Lyssach/Switzerland: VSL International Ltd; 2002.
- Geophysical survey systems Inc. (GSSI). GSSI handbook for RADAR inspection of concrete. Salem, New Hampshire 03079 USA: Geophysical Survey Systems Inc. 12 Industrial Way; 2009.
- Lai WWL, Derobert X, Annan P. A review of ground penetrating radar application in civil engineering: A 30-year journey from Locating and Testing to Imaging and Diagnosis. NDT E Int. 2018;96:58–78.
- Gracia VP, Garcia FG, Abad IR. GPR evaluation of the damage found in the reinforced concrete base of a block of flats: A case study. NDT E Int. 2008;41:341–353.
- Barrile V, Pucinott R. Application of radar technology to reinforced concrete structures: a case study. NDT E Int. 2005;38:596–604.
- Halabe UB, Chen HL, Bhandarkar V, et al. Detection of sub-surface anomalies in concrete bridge decks using ground penetrating radar. ACI Mater J. 1997;94(5):396–408.
- Benedettoa A, Manacordaa G, Simib A, et al. Novel perspectives in bridges inspection using GPR. Case Stud NondestrTest Eval. 2012;27(3):239–251.
- Stryk J, Matula R, Pospisil K. Possibilities of ground penetrating radar usage within acceptance tests of rigid pavements. J Appl Geophys. 2013;97: 11–26.
- Hugenschmidt J, Mastrangelo R. GPR inspection of concrete bridges. Cem Concr Compos. 2006;28: 384–392.
- Neville AM, Brooks JJ. Concrete technology. In: Maldague XPV, Mooren PO, editors. Pearson education limited. 2nd ed. Noida, Uttar Pradesh: Pearson India Education Services Pvt. Ltd.; 2010. p. 314–315.
- Non destructive testing handbook, volume 3. Infrared and thermal testing. American Society of Non Destructive Testing (ASNT); 2001.
- Wiggenhauser H. Active IR-applications in civil engineering. Infrared Phys Technol. 2002;43:233–238.
- Clark MR, McCann DM, Forde MC. Application of infrared thermography to the non-destructive testing of concrete and masonry bridges. NDT E Int. 2003;36:265–275.
- Cotic P, Kolaric D, Bosiljkov VB, et al. Determination of the applicability and limits of void and delamination detection in concrete structures using infrared thermography. NDT E Int. 2015;74:87–93.
- Sultan AA, Washer GA. Comparison of two nondestructive evaluation technologies for the condition assessment of bridge decks. Transp Res Rec. 2018;2672(41):113–122.
- Im SB, Hurlebaus S, Trejo D. Inspection of voids in external tendons of posttensioned bridges. Transp Res Rec J Transp Res Board. 2010;2172(1):115–122.
- Hiasa S, Catbas FN, Matsumoto M, et al. Testing of dynamic infrared thermography application for subsurface damage detection in concrete structures. International Symposium Non-Destructive Testing in Civil Engineering (NDTCE 2015), Berlin, Germany.
- Hurlebaus S, Hueste MBD, Karthik MM, et al. Condition assessment of bridge post-tensioning and stay cable systems using NDE methods. National Cooperative Highway Research Program. Washington, DC: Transportation Research Board of the National Academies NCHRP Report; 2016. (Project 14-28).
- Rieck C, Hillemeier B. Detecting voids inside ducts of bonded steel tendons using impulse thermography. International symposium. Non-Destructive Testing in Civil Engineering, Berlin, Germany; 2003.
- Pollock DG, Dupuis KJ, Lacour B, et al. Detection of voids in prestressed concrete bridges using thermal imaging and ground penetrating radar. USA: Report: Washington state department of transportation; 2008.
- Zhou X, Wang Z, Zhang D. Detecting voids in grouted tendon ducts of post-tensioned concrete structures using three different methods. Canada International Conference on Education, Guelph, Ontario, Canada; 2012.
- Wang Z, Zhou X, Dai G. Sensitivity studies of grout defects in tendon ducts using ground penetrating radar. Int J Digital Content Technol App (JDCTA). 2012;18:227–233.
- Giannopoulos A, Macintyre P, Rodgers S, Forde MC. GPR detection of voids in post-tensioned concrete bridge beams. Proc. SPIE 4758, Ninth International Conference on Ground Penetrating Radar, Santa Barbara, CA; 2002. p. 376-381.
- Muldoon R, Chalker A, Forde M, et al. Identifying voids in plastic ducts in post-tensioning prestressed concrete members by resonant frequency of impact–echo, SIBIE and tomography. Constr Build Mater. 2007;21(3):527–537.
- Bungey JH, Millard SG. Radar inspection of structures. Proc. Instn Civ. Bldgs, London; 1993. p. 173–186.
- Khanna SK Experimental study on applications of infrared thermography in concrete engineering [Master’s thesis]. Kanpur; Indian Institute of Technology Kanpur; February 2002.
- Rao DSP. Infrared thermography and its applications in civil engineering. Indian Concr J. 2008;82(5):41–50.
- Bagavathiappan S, Lahiri BB, Saravanan T, et al. Infrared thermography for condition monitoring – A review. Infrared Phys Technol. 2013;60:35–55.
- Shetty MS. Concrete technology theory and practice. New Delhi: S.Chand and company Ltd; 2011. p. 446–452.
- Pucinotti R, Hinterholz L, D’Elia A, et al. Influence of steel reinforcement on ultrasonic pulses velocity. 4th International conference on NDT; Hellenic Society for NDT, Chania, Crete-Greece; 2007.
- Fodil N, Chemrouk M, Ammar A. Influence of steel reinforcement on ultrasonic pulse velocity as a non-destructive evaluation of high-performance concrete strength. Eur J Environ Civ Eng. 2018;22:1–21.
- Lencis U, Ūdris A, Korjakins A. Decrease of the ultrasonic pulse velocity in concrete caused by reinforcement. J Mater Sci Eng. 2011;(12):1016–1028. DOI: 10.17265/2161-6213/2011.12.016
- Kumar R Some considerations for design of cement grouts for post tensioning application, [Master’s thesis], Kanpur; Indian Institute of Technology Kanpur; 2004.
- Schokker AJ, Koester BD, Breen JE, et al. Development of high performance grouts for bonded post-tensioned structures. USA: Report: Texas department of transportation; 1999.
- GSSI. StructureScan mini LT. [Accessed 2018 Aug 29]. Available from: https://www.geophysical.com/products/structurescan-mini-lt
- Proceq. Pundit ultrasonic pulse velocity and pulse echo tomography. [Accessed 2018 Aug 29]. Available from: https://www.proceq.com/compare/pundit-ultrasonic-pulse-velocity-and-pulse-echo-testing/
- FLIR. Thermal camera for predictive maintenance FLIR T640 model: T640 15° (WI-FI). [Accessed 2018 Aug 29]. Available from: https://www.flir.com/products/t640/
- Bungey JH. Sub-surface radar testing of concrete. Rev Constr Build Mater. 2004;18(1):1–8.
- American society for testing and materials (ASTM). Standard test method for expansion and bleeding of freshly mixed grouts for preplaced-aggregate concrete in the laboratory. (ASTM C940-10a).
- American society for testing and materials (ASTM). Standard test methods for time of setting of hydraulic cement by Vicat needle. ASTM C191.
- American society for testing and materials (ASTM). Standard test method for flow of grout for preplaced-aggregate concrete (Flow cone method). ASTM C939.
- American society for testing and materials. Standard test method for compressive strength of grouts for preplaced-aggregate concrete in the laboratory. ASTM C942.