References
- Ghosh D, Beniwal S, Ganguli A, et al. Reference free imaging of subsurface cracks in concrete using Rayleigh waves. Struct Control Health Monit. 2018;25(10):10. e2246.
- Sharma S, Mukherjee A. Longitudinal guided waves for monitoring chloride corrosion in reinforcing bars in concrete. Struct Health Monit. 2010;9(6):555–567.
- Reou J, Ann K. Electrochemical assessment on the corrosion risk of steel embedment in OPC concrete depending on the corrosion detection techniques. Mater Chem Phys. 2009;113(1):78–84.
- Reis H, Ervin BL, Kuchma DA, et al. Estimation of corrosion damage in steel reinforced mortar using guided waves. J Pressure Vessel Technol. 2005;127(3):255–261.
- Gadve S, Mukherjee A, Malhotra SN. Corrosion of steel reinforcements embedded in FRP wrapped concrete. Constr Build Mater. 2009;23(1):53–161.
- Ghosh D, Kumar R, Ganguli A, et al. Non-destructive evaluation of corrosion induced rebar damage in concrete through ultrasonic imaging. J Mater Civ Eng. 2020;32(10):04020294.
- Beniwal S, Ganguli A. Localized condition monitoring around rebars using focused ultrasonic field and SAFT. Res Non-destructive Eval. 2016;27(1):48–67.
- Ghosh D, Beniwal S, Ganguli A, et al. Simulation of ultrasonic Rayleigh wave based damage detection in concrete structures. Indian J Non Destr Test Eval. 2019;17(16):19–23.
- Sansalone M, Carino NJ. Impact-Echo: a Method for Flaw detection in Concrete using transient Waves. NBSIR 86-3452, National Bureau of Standards, pp.222, sept. 1986.
- Chaudhary M. Effectiveness of Impact Echo testing in detecting flaws in prestressed concrete slabs. Constr Build Mater. 2013;47:753–759.
- Wang Z, Zhou X. Impact-echo based non-destructive evaluation of grout condition in post-tensioned bridge ducts. Adv Mater Res. 2010;168:1122–1125.
- Liang M, Su P. Detection of the corrosion damage of rebar in concrete using impact-echo method. Cement Concr Res. 2001;31(10):1427–1436.
- Alhawat M, Khan A, Ashour A. Evaluation of steel corrosion in concrete structures using impact-echo method. Adv Mater Res. 2020;1158:147–164.
- Rickard L, Choi W. Evaluation of subsurface damage in concrete deck joints using impact echo method. Adv Mater Sci Eng. 2016;2016:1–7.
- Zhang J, Yan W, Cui D. Concrete condition assessment using impact-echo method and extreme learning machines. Sensors. 2016;16(4):447.
- Goldaran R, Turer A, Kouhdaragh M, et al. Identification of corrosion in a prestressed concrete pipe utilizing acoustic emission technique. Constr Build Mater. 2020;242:118053.
- Ramadan S, Gaillet L, Tessier C, et al. Assessment of the stress corrosion cracking in a chloride medium of cables used in prestressed concrete structures by the acoustic emission technique. Meas SciTechnol. 2008;19(11):115702.
- Sharma A, Sharma S, Sharma S, et al. Monitoring invisible corrosion in concrete using a combination of wave propagation techniques. Cem Concr Compos. 2018;90:89–99.
- Lu Y, Li J, Ye L, et al. Guided waves for damage detection in rebar-reinforced concrete beams. Constr Build Mater. 2013;47:370–378.
- Mukherjee A, Sharma S, Sharma S. Corrosion monitoring in infrastructures using ultrasonic wave propagation. 23rd Australasian Conference on the Mechanics of Structures and Materials, 2015, Australia, December 9- 12.
- Li D, Ruan T, Yuan J. Inspection of reinforced concrete interface delamination using ultrasonic guided wave non-destructive test technique. Sci China Technol Sci. 2012;55(10):2893–2901.
- Li D, Zhang S, Yang W, et al. “Corrosion Monitoring and Evaluation of Reinforced Concrete Structures Utilizing the Ultrasonic Guided Wave Technique”. Int J Distrib Sens Netw. 2014;10(2):827130.
- Zou D, Cheng H, Liu T, et al. Monitoring of concrete structure damage caused by sulfate attack with the use of embedded piezoelectric transducers. Smart Mater Struct. 2019;28(11):115041.
- Liu P, Hu Y, Geng B, et al. Investigation on novel embedded piezoelectric ultrasonic transducers for corrosion monitoring of reinforced concrete. Smart Mater Struct. 2019;28(11):115041.
- Grohmann M, Niederleithinger E, Buske S. Geometry determination of a foundation slab using the ultrasonic echo technique and geophysical migration methods. J Non-Destruct Eval. 2016;35:1.
- Müller S, Niederleithinger E, Bohlen T. Reverse time migration: a seismic imaging technique applied to synthetic ultrasonic data. Int J Geophys. 2012;2012:1–7.
- Watanabe T, Trang H, Harada K, et al. Evaluation of corrosion-induced crack and rebar corrosion by ultrasonic testing. Constr Build Mater. 2014;67:197.
- Beniwal S, Ghosh D, Ganguli A. Ultrasonic imaging of concrete using scattered elastic wave modes. NDT E Int. 2016;82:26–35.
- Ganguli A, Gao RX, Liang K, et al. “Experimental investigation of ultrasound wave focusing in attenuative solids. in. IEEE Trans Instrum Meas. 2010;59(9):2261–2271.
- Ghosh D, Beniwal S, Ganguli A (2015) “Detection of defect in concrete slab using Rayleigh waves”. IEEE International Ultrasonics Symposium, Taipei, Taiwan, pp. 1–4.
- De La Haza AO, Samokrutov AA, Samokrutov PA. Assessment of concrete structures using the Mira and Eyecon ultrasonic shear wave devices and the SAFT-C image reconstruction technique. Constr Build Mater. 2013;38:1276–1291.
- Wiggenhauser H, Samokrutov AA, Mayer K, et al. Large aperture ultrasonic system for testing thick concrete structures. J Infrastruct Syst. 2017;23(1):B4016004.
- Choi P, Kim D, Lee B, et al. Application of ultrasonic shear-wave tomography to identify horizontal crack or delamination in concrete pavement and bridge. Constr Build Mater. 2016;121:81–91.
- Choi H, Bittner J, Popovics JS. Comparison of ultrasonic imaging techniques for full-scale reinforced concrete. Transp Res Rec. 2016;2592(1):126–135.
- Kee SH, Zhu J. Using air-coupled sensors to determine the depth of a surface-breaking crack in concrete. J Acoust Soc Am. 2010;127(3):1279–1287.
- Zhu J, Popovics JS. Non-contact imaging for surface opening cracks in concrete with air-coupled sensors. Mater Struct. 2005;38:801–806.
- Abraham O, Popovics JS, and Cottineau LM, et al. Laser Ultrasonics for civil engineering: some applications in development for concrete non-destructive testing. J Phys. 2011;278 012014.
- Selim H, Delgado-Prieto M, Trull J, et al. Defect reconstruction by non-destructive testing with laser induced ultrasonic detection. Ultrasonics. 2020;101:106000.
- An YK, Park B, Sohn H. Complete noncontact laser ultrasonic imaging for automated crack visualization in a plate. Smart Mater Struct. 2013;22:2.
- Jacobs LJ, Whitcomb RW. Laser generation and detection of ultrasound in concrete. J Non-Destruct Eval. 1997;16(2):57–65.
- Furusawa A, Takenaka Y, Nishimura A. Proposal of Laser-Induced ultrasonic guided wave for corrosion detection of reinforced concrete structures in Fukushima Daiichi nuclear power plant decommissioning site. Appl Sci. 2019;9(7):3544.
- Mahbaz S, Cascante G, Dusseault MB. “De-bonding assessment of rebars using an ultrasonic method with laser vibrometer tests and numerical simulations. NDT E Int. 2021;120,:102442.
- Maaddawy E, Tamer A, Soudki KA. Effectiveness of impressed current technique to simulate corrosion of steel reinforcement in concrete. J Mater Civ Eng. 2003;15(1):41–47.
- Sharma S, Mukherjee A. Monitoring corrosion in oxide and chloride environments using ultrasonic guided waves. J Mater Civ Eng. 2011;23(2):207–211.
- Feng W, Tarakbay A, Memon SA, et al. Methods of accelerating chloride-induced corrosion in steel-reinforced concrete: a comparative review. Constr Build Mater. 2021;289:123165.
- Schickert M, Krause M, Müller W. Ultrasonic imaging of concrete elements using reconstruction by synthetic aperture focusing technique. J Mater Civ Eng. 2003;15(3):235–246.
- Ganguli A, Rappaport CM, Abramo D, et al. Synthetic aperture imaging for flaw detection in a concrete medium. NDT E Int. 2012;45(1):79–90.