660
Views
5
CrossRef citations to date
0
Altmetric
Research Article

Field analyzers for lead quantification in drinking water samples

ORCID Icon, ORCID Icon, , & ORCID Icon
Pages 2357-2388 | Published online: 26 Jun 2020

References

  • Akers, D. B., MacCarthy, M. F., Cunningham, J. A., Annis, J., & Mihelcic, J. R. (2015). Lead (Pb) contamination of self-supply groundwater systems in coastal Madagascar and predictions of blood lead levels in exposed children. Environmental Science & Technology, 49(5), 2685–2693. https://doi.org/10.1021/es504517r
  • American Academy of Pediatrics (APHA). (2016). With no amount of lead exposure safe for children, American Academy of Pediatrics calls for stricter regulations. Retrieved January 13, 2020, from https://www.aap.org/en-us/about-the-aap/aap-press-room/Pages/With-No-Amount-of-Lead-Exposure-Safe-for-Children,-American-Academy-of-Pediatrics-Calls-For-Stricter-Regulations.aspx
  • American Academy of Pediatrics (APHA). (2017a). 3010 Introduction, Standard methods for the examination of water and wastewater. https://www.standardmethods.org/doi/full/10.2105/SMWW.2882.039
  • American Academy of Pediatrics (APHA). (2017b). 3030 Preliminary treatment of samples, standard methods for the examination of water and wastewater. https://www.standardmethods.org/doi/abs/10.2105/SMWW.2882.041
  • American Academy of Pediatrics (APHA). (2017c). 3113 Metals by electrothermal atomic absorption spectrometry, standard methods for the examination of water and wastewater. https://www.standardmethods.org/doi/abs/10.2105/SMWW.2882.045
  • American Academy of Pediatrics (APHA). (2017d). 3125 Metals by inductively coupled plasma - Mass spectrometry, standard methods for the examination of water and wastewater. https://www.standardmethods.org/doi/abs/10.2105/SMWW.2882.048
  • American Academy of Pediatrics (APHA). (2017e). 3130 Metals by anodic stripping voltammetry, standard methods for the examination of water and wastewater, American Public Health Association. https://www.standardmethods.org/doi/abs/10.2105/SMWW.2882.049
  • American Academy of Pediatrics (APHA). (2017f). 3500-Pb Lead, standard methods for the examination of water and wastewater. https://www.standardmethods.org/doi/abs/10.2105/SMWW.2882.056
  • ANDalyze. (2018). Lead testing and on-site calibration for water testing, Detection Range: 2 – 100ppb, Champaign, IL, United States. Retrieved January 14, 2020, from http://andalyze.com/wp-content/uploads/Lead-AND010-7-2018.pdf
  • Argent, V. A., Southall, J. M., & D’Costa, E. (1994). Analysis of water for lead and copper using disposable sensor technology [Paper presentation]. Annual Conference of the American Water Works Association, New York, NY, United States, pp. 43–54.
  • ASTM International. (2015). ASTM D3559-15 Standard methods for lead in water, ASTM International, West Conshohocken, PA, United States. https://doi.org/10.1520/D3559-15
  • Baldo, M. A., Daniele, S., Ciani, I., Bragato, C., & Wang, J. (2004). Remote stripping analysis of lead and copper by a mercury-coated platinum microelectrode. Electroanalysis, 16(5), 360–366. https://doi.org/10.1002/elan.200302836
  • Bard, A. J., & Faulkner, L. R. (2001). Electrochemical methods: Fundamentals and applications. John Wiley & Sons, Inc.
  • Boffardi, B. P., & Sherbondy, A. M. (1991). Control of lead corrosion by chemical treatment. Corrosion, 47(12), 966–975. doi: https://doi.org/10.5006/1.3585211
  • Brown, M. J., Raymond, J., Homa, D., Kennedy, C., & Sinks, T. (2011). Association between children’s blood lead levels, lead service lines, and water disinfection, Washington, DC, 1998–2006. Environmental Research, 111(1), 67–74. doi: https://doi.org/10.1016/j.envres.2010.10.003
  • Cartier, C., Bannier, A., Pirog, M., Nour, S., & Prévost, M. (2012). A rapid method for lead service line detection. Journal - American Water Works Association, 104(11), E596–E607. https://doi.org/10.5942/jawwa.2012.104.0143
  • Chang, F.-C., & Lin, Y.-P. (2019). Survey of lead concentration in tap water on a university campus. Environmental Science and Pollution Research International, 26(24), 25275–25285. https://doi.org/10.1007/s11356-019-05771-1
  • Chang, I.-H., Tulock, J. J., Liu, J., Kim, W.-S., Cannon, D. M., Lu, Y., Bohn, P. W., Sweedler, J. V., & Cropek, D. M. (2005). Miniaturized lead sensor based on lead-specific dnazyme in a nanocapillary interconnected microfluidic device. Environmental Science & Technology, 39(10), 3756–3761. https://doi.org/10.1021/es040505f
  • Clark, B. N., Masters, S. V., & Edwards, M. A. (2015). Lead release to drinking water from galvanized steel pipe coatings. Environmental Engineering Science, 32(8), 713–721. https://doi.org/10.1089/ees.2015.0073
  • Deibler, K., & Basu, P. (2013). Continuing issues with lead: Recent advances in detection. European Journal of Inorganic Chemistry, 2013(7), 1086–1096. https://doi.org/10.1002/ejic.201200997
  • Del Toral, M. A., Porter, A., & Schock, M. R. (2013). Detection and evaluation of elevated lead release from service lines: A field study. Environmental Science & Technology, 47(16), 9300–9307. https://doi.org/10.1021/es4003636
  • Deshommes, E., Bannier, A., Laroche, L., Nour, S., & Prévost, M. (2016). Monitoring-based framework to detect and manage lead water service lines. Journal - American Water Works Association, 108(11), E555–E570. https://doi.org/10.5942/jawwa.2016.108.0167
  • Deshommes, E., Laroche, L., Nour, S., Cartier, C., & Prévost, M. (2010). Source and occurrence of particulate lead in tap water. Water Research, 44(12), 3734–3744. doi: https://doi.org/10.1016/j.watres.2010.04.019
  • Deshommes, E., Nour, S., Richer, B., Cartier, C., & Prévost, M. (2012). POU devices in large buildings: Lead removal and water quality. Journal - American Water Works Association, 104(4), E282–E297. https://doi.org/10.5942/jawwa.2012.104.0058
  • Deshommes, E., Trueman, B., Douglas, I., Huggins, D., Laroche, L., Swertfeger, J., Spielmacher, A., Gagnon, G. A., & Prévost, M. (2018). Lead levels at the tap and consumer exposure from legacy and recent lead service line replacements in six utilities. Environmental Science & Technology, 52(16), 9451–9459. https://doi.org/10.1021/acs.est.8b02388
  • District of Columbia Public Schools. (2018). Water testing for lead. Retrieved January 22, 2020, from https://dcps.dc.gov/page/water-testing-lead
  • Doré, E., Deshommes, E., Andrews, R. C., Nour, S., & Prévost, M. (2018). Sampling in schools and large institutional buildings: Implications for regulations, exposure and management of lead and copper. Water Research, 140, 110–122. doi: https://doi.org/10.1016/j.watres.2018.04.045
  • Ebner, P. D., Deering, A., Mojadady, M., Rahimi, Z., Amini, R., Popal, M., Eshaqzai, N., Barak, S., Amini, S., Azizi, E., Morshid, E., Mohammadi, N., Rahimi, M., McNamara, K., & Oliver, H. F. (2018). Capacity building through water quality and safety analyses in Herat, Afghanistan. Journal of Food Protection, 81(9), 1467–1471. doi: https://doi.org/10.4315/0362-028X.JFP-18-051
  • Edwards, M., & Dudi, A. (2004). Role of Chlorine and chloramine in corrosion of lead-bearing plumbing materials. Journal - American Water Works Association, 96(10), 69–81. https://doi.org/10.1002/j.1551-8833.2004.tb10724.x
  • Edwards, M., Triantafyllidou, S., & Best, D. (2009). Elevated blood lead in young children due to lead-contaminated drinking water: Washington, D.C., 2001 − 2004. Environmental Science & Technology, 43(5), 1618–1623. https://doi.org/10.1021/es802789w
  • Elfland, C., Scardina, P., & Edwards, M. (2010). Lead-contaminated water from brass plumbing devices in new buildings. Journal - American Water Works Association, 102(11), 66–76. https://doi.org/10.1002/j.1551-8833.2010.tb11340.x
  • Formal, C. L., Lytle, D. A., Harmon, S., Wahman, D., & DeSantis, M. K. (2020). The impact of orthophosphate on the solubility and properties of lead nanoparticles, manuscript under preparation.
  • Gulson, B. L., Law, A. J., Korsch, M. J., & Mizon, K. J. (1994). Effect of plumbing systems on lead content of drinking water and contribution to lead body burden. Science of the Total Environment, 144(1-3), 279–284. doi: https://doi.org/10.1016/0048-9697(94)90447-2
  • Hach. (2012). Method 8317 Leadtrak Fast column extraction method, p. 8. https://www.hach.com/asset-get.download-en.jsa?id=7639983725
  • Hanna-Attisha, M., LaChance, J., Sadler, R. C., & Schnepp, A. C. (2016). Elevated blood lead levels in children associated with the flint drinking water crisis: A spatial analysis of risk and public health response. American Journal of Public Health, 106(2), 283–290. https://doi.org/10.2105/AJPH.2015.303003
  • Health Canada. (2019). Guidelines for Canadian Drinking Water Quality: Guideline Technical Document – Lead (H144-13/11-2018E-PDF). Water and Air Quality Bureau – Healthy Environments and Consumer Safety Branch, p. 113, Ottawa, ON, Canada. https://www.canada.ca/content/dam/hc-sc/documents/services/publications/healthy-living/guidelines-canadian-drinking-water-quality-guideline-technical-document-lead/guidance-document/guidance-document.pdf
  • Hulsmann, A. D. (1990). Particulate lead in water supplies. Water and Environment Journal, 4(1), 19–25. https://doi.org/10.1111/j.1747-6593.1990.tb01553.x
  • Industrial Test Systems Inc. (2019). Exact LEADQuick instruction manual, ideal for screening for lead, mercury and cadmium in potable water, p. 20, Rock Hill, SC, United States. Retrieved January 13, 2020, from http://sensafe.com/content/486900-BT.pdf
  • Kim, H. N., Ren, W. X., Kim, J. S., & Yoon, J. (2012). Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions. Chemical Society Reviews, 41(8), 3210–3244. https://doi.org/10.1039/C1CS15245A
  • Kimbrough, D. E. (2007). Brass corrosion as a source of lead and copper in traditional and all-plastic distribution systems. Journal - American Water Works Association, 99(8), 70–76. https://doi.org/10.1002/j.1551-8833.2007.tb08008.x
  • Krajewski, A. (2016). Analysis of heavy metal exposures and evaluation of detection methods for heavy metals in drinking water [Doctoral dissertation, University of Illinois at Chicago]. https://indigo.uic.edu/articles/Analysis_of_Heavy_Metal_Exposures_and_Evaluation_of_Detection_Methods_for_Heavy_Metals_in_Drinking_Water/10782338/files/19295717.pdf
  • Kriss, R., Pieper, K., Parks, J., & Edwards, M. (2019). Detecting and measuring lead in drinking water using at-home test kits [Paper presentation]. Water Quality Technology Conference of the American Water Works Association, Dallas, TX, United States.
  • Lanphear, B. P., Hornung, R., Khoury, J., Yolton, K., Baghurst, P., Bellinger, D. C., Canfield, R. L., Dietrich, K. N., Bornschein, R., Greene, T., Rothenberg, S. J., Needleman, H. L., Schnaas, L., Wasserman, G., Graziano, J., & Roberts, R. (2005). Low-level environmental lead exposure and children’s intellectual function: An international pooled analysis. Environmental Health Perspectives, 113(7), 894–899. https://doi.org/10.1289/ehp.7688
  • Lanphear, B. P., Rauch, S., Auinger, P., Allen, R. W., & Hornung, R. W. (2018). Low-level lead exposure and mortality in US adults: A population-based cohort study. The Lancet. Public Health, 3(4), e177–e184. doi: https://doi.org/10.1016/S2468-2667(18)30025-2
  • Levallois, P., St-Laurent, J., Gauvin, D., Courteau, M., Prévost, M., Campagna, C., Lemieux, F., Nour, S., D'Amour, M., & Rasmussen, P. E. (2014). The impact of drinking water, indoor dust and paint on blood lead levels of children aged 1-5 years in Montréal (Québec, Canada). Journal of Exposure Science & Environmental Epidemiology, 24(2), 185–191. https://doi.org/10.1038/jes.2012.129
  • Lin, N. H., Torrents, A., Davis, A. P., Zeinali, M., & Taylor, F. A. (1997). Lead corrosion control from lead, copper‐lead solder, and brass coupons in drinking water employing free and combined chlorine. Journal of Environmental Science and Health. Part A: Environmental Science and Engineering and Toxicology, 32(4), 865–884. https://doi.org/10.1080/10934529709376583
  • Liu, J., & Lu, Y. (2003). A colorimetric lead biosensor using dnazyme-directed assembly of gold nanoparticles. Journal of the American Chemical Society, 125(22), 6642–6643. https://doi.org/10.1021/ja034775u
  • Lytle, D. A., Shock, M. R., Dues, N. R., & Clark, P. J. (1993). Investigating the preferential dissolution of lead from solder particulates. Journal - American Water Works Association, 85(7), 104–110. https://doi.org/10.1002/j.1551-8833.1993.tb06030.x
  • Manton, W. I., Angle, C. R., Stanek, K. L., Reese, Y. R., & Kuehnemann, T. J. (2000). Acquisition and retention of lead by young children. Environmental Research, 82(1), 60–80. doi: https://doi.org/10.1006/enrs.1999.4003
  • McCormick, L. A. (2018). Advances in lead in water testing methods and requirements: lessons from a pilot child care centers [Paper presentation]. Water Quality Technology Conference of the American Water Works Association, Toronto, ON, Canada.
  • McCormick, L. A., Lovell, S. C. (2019). Putting children first: Tackling lead in water at child care facilities, p. 43, Environmental defense fund, New York, NY, United States. Retrieved January 12, 2020 from https://www.edf.org/sites/default/files/documents/edf_child_care_report-062518.pdf
  • McNeil, L. S., & Edwards, M. (2004). Importance of Pb and Cu particulate species for corrosion control. Journal of Environmental Engineering, (130)(2), 136–144. doi: https://doi.org/10.1061/(ASCE)0733-9372(2004)130:2(136) https://doi.org/10.1061/(ASCE)0733-9372(2004)130:2(136)
  • Metrohm. (2019). Manual, 946 Portable Va Analyzer, p. 81, Herisau, Switzerland. Retrieved January 13, 2020, from https://partners.metrohm.com/GetDocumentPublic?action=get_dms_document&docid=3256850
  • Michigan Department of Environment, Great Lakes and Energy. (2020). School drinking water training program. Retrieved January 22, 2020, from https://www.michigan.gov/egle/0,9429,7-135-3313_3675_3691-474608–,00.html
  • Miller, S. A. (2004). Investigation of lead solubility and orthophosphate addition in high pH low DIC water [Masters of Science Dissertation, University of Cincinnati], https://etd.ohiolink.edu/!etd.send_file?accession=ucin1406821208&disposition=attachment
  • Minnesota Department of Education and Department of Health. (2019). Reducing Lead in drinking water: A technical guidance and model plan for Minnesota’s public schools. Minnesota Department of Education - Division of School Finance – Long-Term Facilities Maintenance and Minnesota Department of Health - Environmental Health Division - Drinking Water Protection, p. 28. Retrieved January 13, 2020, from https://www.health.state.mn.us/communities/environment/water/docs/pbschoolguide.pdf
  • ModernWater. (2012). Zinc, cadmium & lead at thin mercury film - Pdv6000ultra.
  • Mushak, P. (1998). Uses and Limits of Empirical Data in Measuring and Modeling Human Lead Exposure. Environmental Health Perspectives, 106(suppl 6), 1467–1484. https://doi.org/10.1289/ehp.98106s61467
  • Newkirk, S. H. (2005). Detection levels of drinking water contaminants using field portable ultraviolet and visible light (UV/Vis) spectrophotometry [Masters of Science in Public Health, Uniformed Services University of the Health Sciences]. https://apps.dtic.mil/dtic/tr/fulltext/u2/a439130.pdf
  • Ngueta, G., Abdous, B., Tardif, R., St-Laurent, J., & Levallois, P. (2016). Use of a cumulative exposure index to estimate the impact of tap water lead concentration on blood lead levels in 1- to 5-year-old children (Montreal, Canada). Environmental Health Perspectives, 124(3), 388–395. https://doi.org/10.1289/ehp.1409144
  • Null, E. L., Dugan, M. (2012). Heavy metals water testing powered by DNA: Fast, sensitive, specific, platform technology for metals detection, p. 14. Retrieved January 14, 2020, from http://andalyze.com/wp-content/uploads/ANDalyze-Heavy-Metal-Analysis-White-Paper.pdf
  • Odell, L., Pierson, G., & Donald, C. (1991). Reducing lead in school’s drinking water: A case study [Paper presentation]. Water Quality Technology Conference of the American Water Works Association, Orlando, FL, United States. pp. 353–378.
  • Palintest. (1999). Method 1001: Lead in drinking water by differential pulse anodic stripping voltammetry, p. 18, Erlanger, KY, United States.
  • Palintest. (2019). Scanning-analyzer user-manual. Retrieved January 14, 2020, from https://www.palintest.com/wp-content/uploads/2019/04/Scanning-Analyzer_User-Manual_Web.pdf
  • Pelletier, K. (2019). Personal Communication on Field Analyzers with Triantafyllidou, S.
  • Pinto, J. A., McAnally, A. S., & Flora, J. R. V. (1997). Evaluation of lead and copper corrosion control techniques. Journal of Environmental Science and Health. Part A: Environmental Science and Engineering and Toxicology, 32(1), 31–53. https://doi.org/10.1080/10934529709376526
  • Postawa, A. (2012). Best practice guide on the sampling and monitoring of metals in drinking water. IWA Publishing.
  • Riblet, C., Deshommes, E., Laroche, L., & Prévost, M. (2019). True exposure to lead at the tap: Insights from proportional sampling, regulated sampling and water use monitoring. Water Research, 156, 327–336. doi: https://doi.org/10.1016/j.watres.2019.03.005
  • Sandvig, A., Kwan, P., Kirmeyer, G., Maynard, B., Mast, D., Trussell, R. R., Trussell, S., Cantor, A., & Prescott, A. (2008). Contribution of service line and plumbing fixtures to lead and copper rule compliance issues, American Water Works Research Foundation, Denver, CO, USA.
  • Savely, S. M., Emery, R. J., & Connor, T. H. (2000). A comparison of methods for determining lead content in drinking water: A portable anodic stripping voltammetry instrument method versus the standard EPA 239.2 Method. AIHAJ: A Journal for the Science of Occupational and Environmental Health and Safety, 61(4), 557–562. https://doi.org/10.1080/15298660008984568
  • Schock, M. R., & Gardels, M. C. (1983). Plumbosolvency reduction by high pH and low carbonate—solubility relationships. Journal - American Water Works Association, 75(2), 87–91. https://doi.org/10.1002/j.1551-8833.1983.tb05072.x
  • Schock, M. R., & George, G. K. (1993). Evaluation of a field test kit for monitoring lead in drinking water. Journal - American Water Works Association, 85(8), 90–100. https://doi.org/10.1002/j.1551-8833.1993.tb06046.x
  • Sett, A., Das, S., & Bora, U. (2014). Functional nucleic-acid-based sensors for environmental monitoring. Applied Biochemistry and Biotechnology, 174(3), 1073–1091. https://doi.org/10.1007/s12010-014-0990-3
  • State of Illinois. (2020). Public Act 099-0922. http://www.ilga.gov/legislation/publicacts/99/099-0922.htm
  • Swertfeger, J., Harman, D. J., Shrive, C., Metz, D. H., & DeMarco, J. (2006). Water quality effects of partial line replacement [Paper presentation]. Annual conference of the American water works association, San Antonio, TX, United States.
  • Tang, X., Wang, P.-Y., & Buchter, G. (2018). Ion-selective electrodes for detection of lead (Ii) in drinking water: A mini-review. Environments, 5(9), 95. https://doi.org/10.3390/environments5090095
  • Trace2O. (2020). Portable Metalyser Deluxe Hm2000. Retrieved January 13, 2020, from https://www.trace2o.com/shop/metalyser-deluxe-hm2000/
  • Triantafyllidou, S., & Edwards, M. (2012). Lead (Pb) in tap water and in blood: Implications for lead exposure in the United States. Critical Reviews in Environmental Science and Technology, 42(13), 1297–1352. https://doi.org/10.1080/10643389.2011.556556
  • Triantafyllidou, S., Nguyen, C. K., Zhang, Y., & Edwards, M. A. (2013). Lead (Pb) quantification in potable water samples: Implications for regulatory compliance and assessment of human exposure. Environmental Monitoring and Assessment, 185(2), 1355–1365. https://doi.org/10.1007/s10661-012-2637-6
  • Trueman, B. F., Camara, E., & Gagnon, G. A. (2016). Evaluating the effects of full and partial lead service line replacement on lead levels in drinking water. Environmental Science & Technology, 50(14), 7389–7396. https://doi.org/10.1021/acs.est.6b01912
  • United States Environmental Protection Agency. (1994a). Method 200.8, Revision 5.4: Determination of trace elements in waters and wastes by inductively coupled plasma-mass spectrometry. Office of Research and Development, p. 58, Cincinnati, OH, United States.
  • United States Environmental Protection Agency. (1994b). Method 200.9, Revision 2.2: Determination of Trace Elements by Stabilized Temperature Graphite Furnace Atomic Absorption. Environmental Monitoring and Support Laboratory - Office of Research and Development, Cincinnati, OH, United States.
  • United States Environmental Protection Agency. (1994c). Technical notes on drinking water methods. Office of Research and Development (ed.), p. 112. Washington D.C, United States.
  • United States Environmental Protection Agency. (2003). Method 200.5 Determination of trace elements in drinking water by axially viewed inductively coupled plasma- atomic emission spectrometry, Cincinnati, OH, United States.
  • United States Environmental Protection Agency. (2013). Environmental technology verification report: ANDalyze Lead 100 Test Kit and AND1000 Fluorimeter.
  • United States Environmental Protection Agency. (2019a). Analytical methods approved for drinking water compliance monitoring of inorganic contaminants and other inorganic constituents. Office of Water, p. 66.
  • United States Environmental Protection Agency. (2019b). Basic information about lead in drinking water. Retrieved January 20, 2020, from https://www.epa.gov/ground-water-and-drinking-water/basic-information-about-lead-drinking-water
  • United States Environmental Protection Agency. (2019c). CFR Title 40 - Protection of environment, Chapter I - Environmental protection agency, Subchapter D. Water Programs, Part 141. National Drinking Water Regulations, Subpart I. Control of Lead and Copper, Section 141.80 General Requirements, Washington D.C, United States.
  • van den Hoven, T., & Slaats, N. (2006). Analytical methods for drinking water. In Advances in sampling and analysis (pp. 63–113). Wiley.
  • W.K. Kellogg Foundation. (2016). Managing lead in drinking water at schools and early childhood education facilities.
  • Wasserstrom, L., Nelson, J., Webb, D., McCormick, L. A., Triantafyllidou, S., Patrick, D., & Swertfeger, J. (2019). Assessing portable analyzers for lead testing in school drinking water [Paper presentation]. Water Quality Technology Conference of the American Water Works Association, Dallas, TX, United States.
  • Wiese, P. M. (1989). Monitoring method for lead in first-draw drinking water samples [Paper presentation]. Annual Conference and Exposition of the American Water Works Association, Los Angeles, CA, United States., pp. 1309–1313
  • Woebkenberg, M. L., & Ashley, K. (1998). Instrument performance criteria. Applied Occupational and Environmental Hygiene, 13(2), 94–98. https://doi.org/10.1080/1047322X.1998.10389131
  • Ziegler, E. E., Edwards, B. B., Jensen, R. L., Mahaffey, K. R., & Fomon, S. J. (1978). Absorption and retention of lead by infants. Pediatric Research, 12(1), 29–34. https://doi.org/10.1203/00006450-197801000-00008

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.