REFERENCES
- Hanko, V.P.; Rohrer, J.S. Determination of Carbohydrates, Sugar Alcohols, and Glycols in Cell Cultures and Fermentation Broths Using High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection. Anal. Biochem. 2000, 283(2), 192–199.
- Palmqvist, E.; Galbe, M.; Hahn-Hägerdal, B. Evaluation of Cell Recycling in Continuous Fermentation of Enzymatic Hydrolysates of Spruce with Saccharomyces Cerevisiae and On-line Monitoring of Glucose and Ethanol. Appl. Microbiol. Biot. 1998, 50(5), 545–551.
- Zook, C.M.; LaCourse, W.R. Pulsed Amperometric Detection of Microdialysates from the Glucose Oxidase Reaction. Anal. Chem. 1998, 70(4), 801–806.
- Stenken, J.A.; Puckett, D.L.; Lunte, S.M.; Lunte, C.E. Detection of N-acetylcysteine, Cysteine and Their Disulfides in Urine by Liquid Chromatography with a Dual-electrode Amperometric Detector. J. Pharmaceut. Biomed. 1990, 8(1), 85–89.
- Torto, N.; Gorton, L.; Laurell, T.; Marko-Varga, G. Technical Issues of in vitro Microdialysis Sampling in Bioprocess Monitoring. Trends Anal. Chem. 1999, 18(4), 252–260.
- Morrison, P.F.; Bungay, P.M.; Hsiao, J.K.; Mefford, I.N.; Dykstra, K.H.; Dedrick, R.L. Quantitative Microdialysis. In Techniques in the Behavioral and Neural Sciences; Robinson, T.E. Justice Jr., J.B. Eds.; Elsevier, New York, 1991; Vol. 7, pp. 47–80.
- Hansen, P.K.; Davies, M.I.; Lunte, S.M.; Lunte, C.E. Pharmacokinetic and Metabolism Studies using Microdialysis Sampling. J. Pharm. Sci. 1999, 88(1), 14–27.
- Bungay, P.M.; Morrison, P.F.; Dedrick, R.L. Steady-state Theory for Quantitative Microdialysis of Solutes and Water in vivo and in vitro. Life Sci. 1990, 46(2), 105–119.
- Buttler, T.; Nilsson, C.; Gorton, L.; Marko-Varga, G.; Laurell, L. Membrane Characterisation and Performance of Microdialysis Probes Intended for Use as Bioprocess Sampling Units. J. Chromatogr. A 1996, 725(1), 41–56.
- Olson, R. J.; Justice Jr. J.B. Quantitative Microdialysis under Transient Conditions. Anal. Chem. 1993, 65(8), 1017–1022.
- Snyder, K.L.; Nathan, A.Y.; Stenken, J.A. Diffusion and Calibration Properties of Microdialysis Sampling membranes in Biological Media. Analyst 2001, 126(8), 1261–1268.
- Zook, C.M.; LaCourse, W.R. Pulsed Amperometric Detection of Carbohydrates in Fruit Juices Following High Performance Anion Exchange Chromatography. Curr. Sep. 1998, 17(2), 41–45.
- Modi, S.J.; LaCourse, W.R. Monitoring Carbohydrate Enzymatic Reactions by Quantitative in vitro Microdialysis. J. Chromatogr. A 2006, 1118(1), 125–133.