References
- Primmerman, C. A. Detection of Biological Agents. Linc. Lab. J 2000, 12, 3–32.
- Roffey, R.; Lantorp, K.; Tegnell, A.; Elgh, F. Biological Weapons and Bioterrorism Preparedness: importance of Public-Health Awareness and International Cooperation. Clin. Microbiol. Infect. 2002, 8, 522–528. DOI: https://doi.org/10.1046/j.1469-0691.2002.00497.x.
- Jeys, T. H.; Herzog, W. D.; Hybl, J. D.; Czerwinski, R. N.; Sanchez, A. Advanced Trigger Development. Linc. Lab. J. 2007, 17, 29–62.
- Jonsson, P.; Kullander, F. Bioaerosol Detection with Fluorescence Spectroscopy. Bioaerosol Detection Technologies; Springer: New York, NY, 2014; pp 111–141. DOI: https://doi.org/10.1007/978-1-4419-5582-1_7.
- Jonsson, P.; Kullander, F.; Vahlberg, C.; Jelger, P.; Tiihonen, M.; Wästerby, P.; Tjärnhage, T.; Lindgren, M. Spectral Detection of Ultraviolet Laser Induced Fluorescence from Individual Bio-Aerosol Particles. In Optically Based Biological and Chemical Detection for Defence III, Proc. SPIE: Stockholm, Sweden, 2006; pp 6398:63980F. DOI: https://doi.org/10.1117/12.689666.
- Sivaprakasam, V.; Lin, H. B.; Huston, A. L.; Eversole, J. D. Spectral Characterization of Biological Aerosol Particles Using Two-Wavelength Excited Laser-Induced Fluorescence and Elastic Scattering Measurements. Opt. Express 2011, 19, 6191–6208. DOI: https://doi.org/10.1364/OE.19.006191.
- Choi, K.; Ha, Y.; Lee, H. K.; Lee, J. Development of a Biological Aerosol Detector Using Laser-Induced Fluorescence and a Particle Collection System. Instr. Sci. Tech. 2014, 42, 200–214. DOI: https://doi.org/10.1080/10739149.2013.855639.
- Jeong, Y. S.; Lee, J. M.; Park, J.; Chong, E.; Choi, K. Development of a Real-Time Handheld Bioaerosol Monitoring System Using Ultraviolet-Light Emitting Diode Induced Fluorescence. Instrum. Sci. Technol 2020, 48, 417–430. DOI: https://doi.org/10.1080/10739149.2020.1735413.
- Carrano, J. Chemical and Biological Sensor Standards Study; Defense Advanced Research Projects Agency: Arlington, VA, 2005.
- Poldmae, A.; Cabalo, J.; De Lucia, M.; Narayanan, F.; Strauch, L. III; Sickenberger, D. Biological Aerosol Detection with the Tactical Biological (TAC-BIO) Detector. In Optically Based Biological and Chemical Detection for Defence III, Proc. SPIE: Stockholm, Sweden, 2006; pp 6398:63980E. DOI: https://doi.org/10.1117/12.687944.
- Brosseau, L. M.; Vesley, D.; Rice, N.; Goodell, K.; Nellis, M.; Hairston, P. Differences in Detected Fluorescence among Several Bacterial Species Measured with a Direct-Reading Particle Sizer and Fluorescence Detector. Aerosol. Sci. Technol. 2000, 32, 545–558. DOI: https://doi.org/10.1080/027868200303461.
- Shannak, B.; Corsmeier, U.; Kottmeier, C.; Al-Azab, T. Wind Tunnel Study of Twelve Dust Samples by Large Particle Size. Atmos. Environ. 2014, 98, 442–453. DOI: https://doi.org/10.1016/j.atmosenv.2014.08.062.
- Park, J.; Jeong, Y. S.; Nam, H.; Choi, K. Signal Encoder of Real-Time Bio-Aerosol Counter Using 280nm UV-LED Induced Fluorescence. IEEE Sensors J. 2020, 20, 13471–13479. DOI: https://doi.org/10.1109/JSEN.2020.3006880.