References
- Thermo Scientific NanoDrop Products. Thermo Fisher Scientific. http://tools.thermofisher.com/content/sfs/brochures/Thermo-Scientific-NanoDrop-Products-Brochure-EN.pdf (accessed May 14, 2021).
- NanoPhotometer NP80/N60/N50/C40 User Manual. Implen GmbH. https://www.implen.de/wp-content/uploads/2015/08/User-ManualV1.1.0_NP80_N60_N50_C40-15_08_14.pdf (accessed May 14, 2021).
- FastTrack UV/VIS Spectroscopy. Mettler-Toledo GmbH. https://www.mt.com/dam/Analytical/uv-vis/uv-pdf/family-bro/30256091A_V12.15_UVVIS_Excell_Family_Bro_EN_LR.pdf (accessed May 14, 2021).
- DS-11 Series Comparison to NanoDrop One. Denovix. https://www.denovix.com/tn-166-ds-11-series-comparison-to-nanodrop%E2%84%A2-one (accessed May 14, 2021).
- Senra-Ferreiro, S.; Pena-Pereira, F.; Lavilla, I.; Bendicho, C. Griess micro-assay for the determination of nitrite by combining fibre optics-based cuvetteless UV-vis micro-spectrophotometry with liquid-phase microextraction. Anal. Chim. Acta. 2010, 668, 195–200. DOI: https://doi.org/10.1016/j.aca.2010.04.038.
- Abadi, M. D. M.; Ashraf, N.; Chamsaz, M.; Shemirani, F. An Overview of Liquid Phase Microextraction Approaches Combined with UV-Vis spectrophotometry. Talanta 2012, 99, 1–12. DOI: https://doi.org/10.1016/j.talanta.2012.05.027.
- Passos, M. L. C.; Saraiva, M. L. F. S. Detection in UV-Visible Spectrophotometry: Detectors, Detection Systems, and Detection Strategies. Measurement 2019, 135, 896–904. DOI: https://doi.org/10.1016/j.measurement.2018.12.045.
- Oh, S. R.; Kim, S. Micro-Volume Spectrophotometer with a Slope Spectroscopy Technique. Measurement 2021, 167, 108270. DOI: https://doi.org/10.1016/j.measurement.2020.108270.
- Desjardins, P.; Hansen, J. B.; Allen, M. Microvolume Protein Concentration Determination Using the NanoDrop 2000c Spectrophotometer. J. Vis. Exp 2009. DOI: https://doi.org/10.3791/1610.
- Yoo, H.-B.; Yang, I.; Kim, J. H.; Jung, I.-I.; Kang, H.; Jung, H.; Park, I.-Y.; Kim, Y. H.; Park, S.-R. High-Sensitivity Microvolume UV Absorption Spectrometry for Routine Analysis of Small-Volume Biological Samples. Biotechniques. 2021, 70, 251–262. DOI: https://doi.org/10.2144/btn-2021-0005.
- Shojaei-Baghini, E.; Zheng, Y.; Sun, Y. Automated Micropipette Aspiration of Single Cells. Ann. Biomed. Eng. 2013, 41, 1208–1216. DOI: https://doi.org/10.1007/s10439-013-0791-9.
- Heinrich, V.; Rawicz, W. Automated, High-Resolution Micropipet Aspiration Reveals new Insight into the Physical Properties of Fluid Membranes. Langmuir 2005, 21, 1962–1971. DOI: https://doi.org/10.1021/la047801q.
- Liu, X.; Wang, Y.; Sun, Y. Cell Contour Tracking and Data Synchronization for Real-Time, High-Accuracy Micropipette Aspiration. IEEE Trans. Automat. Sci. Eng. 2009, 6, 536–543. DOI: https://doi.org/10.1109/TASE.2009.2021356.
- Kong, F.; Yuan, L.; Zheng, Y. F.; Chen, W. Automatic Liquid Handling for Life Science: A Critical Review of the Current State of the Art. J. Lab. Autom. 2012, 17, 169–185. DOI: https://doi.org/10.1177/2211068211435302.
- Uematsu, C.; Makino, I.; Matsunaga, T.; Harada, K. An Automated Liquid Handling System for Polymerase Chain Reaction Sample Preparation. J. Biosci. Bioeng. 2004, 97, 432–435. DOI: https://doi.org/10.1016/S1389-1723(04)70233-9.
- Maya, F.; Horstkotte, B.; Estela, J. M.; Cerdà, V. Automated in-Syringe Dispersive Liquid-Liquid Microextraction. Trend. Anal. Chem. 2014, 59, 1–8. DOI: https://doi.org/10.1016/j.trac.2014.03.009.
- Chayen, N. E.; Shaw Stewart, P. D.; Maeder, D. L.; Blow, D. M. An Automated System for Micro-Batch Protein Crystallization and Screening. J. Appl. Crystallogr. 1990, 23, 297–302. DOI: https://doi.org/10.1107/S0021889890003260.
- McCormick, M. L.; Banishki, N.; Powell, S.; Rumack, A.; Garrett, J. M. A Low Cost Multi-Level Sampling Device for Synchronous Aseptic Collection of Environmental Water Samples. J. Microbiol. Methods. 2014, 105, 51–53. DOI: https://doi.org/10.1016/j.mimet.2014.07.014.
- Lenk, G.; Ullah, S.; Stemme, G.; Beck, O.; Roxhed, N. Evaluation of a Volumetric Dried Blood Spot Card Using a Gravimetric Method and a Bioanalytical Method with Capillary Blood from 44 Volunteers. Anal. Chem. 2019, 91, 5558–5565. DOI: https://doi.org/10.1021/acs.analchem.8b02905.
- Han, S. D.; Kim, G. B.; Lee, S. J. A New Flow Control Technique for Handling Infinitesimal Flows inside a Lab-On-a-Chip. Kor. Soc. Mech. Eng. 2006, 30, 110–116. DOI: https://doi.org/10.3795/KSME-B.2006.30.2.110.
- Ion, V.; Legoff, C.; Cavalier, E.; Delanaye, P.; Servais, A.-C.; Muntean, D.-L.; Fillet, M. Determination of Iohexol by Capillary Blood Microsampling and UHPLC-MS/MS. J. Pharm. Anal. 2019, 9, 259–265. DOI: https://doi.org/10.1016/j.jpha.2019.06.003.
- Kang, H.; Park, J.; Cho, J.; Kim, J.; Oh, J. A New Method for Maintaining Constant Dither Amplitude in Low Frequency PWM. AECE. 2017, 17, 89–94. DOI: https://doi.org/10.4316/AECE.2017.01013.
- Hardware Assessment: OPB9000 Reflective Light Sensor from TTElectronics. EETech Media LLC. https://www.allaboutcircuits.com/projects/hardware-assessment-opb9000-reflective-light-sensor-TTElectronics (accessed May 14, 2021).
- SMD Reflective Optical Sensor OPB9000. TT Electronics. https://www.ttelectronics.com/TTElectronics/media/ProductFiles/Optoelectronics/Datasheets/OPB9000.pdf (accessed May 14, 2021).