REFERENCES
- ANSI/ASHRAE . 1991 . Method of Testing Air-to-air Heat Exchangers Atlanta : ASHRAE. . Standard 84–1991
- ANSI/ASME . 1985 . Instruments and Apparatus—Part 1: Measurement Uncertainty New York : ASME. . Standard PTC 19.1
- ANSI/ASME . 1991 . Air Cooled Heat Exchangers New York : ASME. . Standard PTC 30
- ASHRAE . 1997 . Fundamentals Handbook. Atlanta : ASHRAE. .
- ASHRAE . 1996 . HVAC Systems and Equipment Handbook. Atlanta : ASHRAE. .
- ASHRAE . 1995 . HVAC Applications Handbook. Atlanta : ASHRAE. .
- Chang , W. R. , Wang , C. and Chang , Y. J. 1994 . Effect of an Inclined Angle on the Heat Transfer and Pressure Drop Characteristics of a Wavy-Finned-Tube Heat Exchanger . ASHRAE Transactions , 100 ( 2 ) : 826 – 832 .
- Dhital , P. , Besant , R. W. and Schoenau , G. J. 1995 . Integrating Run-Around Heat Exchanger Systems into the Design of Large Office Buildings . ASHRAE Transactions , 101 ( 2 ) : 978 – 990 .
- Hill , J. M. and Jeter , S. M. 1994 . The Use of Heat Pipe Heat Exchangers for Enhanced Dehumidification . ASHRAE Transactions , 100 ( 1 ) : 91 – 102 .
- Hill , J. M. and Lau , A. S. 1993 . Performance of Supermarket Air-conditioning Systems Equipped with Heat Pipe Heat Exchangers . ASHRAE Transactions , 99 ( 1 ) : 1315 – 1330 .
- Huang , L. , El-Genk , M. S. and Tournier , J. Transient Performance of an Inclined Water Heat Pipe With a Screen Wick . Proc. 29th National Heat Transfer Conference . pp. 87 – 92 .
- Huang , B. J. and Tsuei , J. T. 1985 . A Method of Analysis for Heat Pipe Heat Exchangers . Journal of Heat and Mass Transfer , 28 ( 3 ) : 563 – 571 .
- Hunn , B. D. and Peterson , J. L. 1996 . Cost Effectiveness of Indirect Evaporative Cooling for Buildings in Texas . ASHRAE Transactions , 102 ( 2 ) : 434 – 447 .
- Incropera , F. P. and DeWitt , D. P. 1996 . Fundamentals of Heat and Mass Transfer, , 4th edition New York : John Wiley & Sons. .
- ISO . 1991 . Measurement of Fluid Flow by Means of Pressure Differential Devices—Part 1: Orifice Plates, Nozzles, and Venturi Tubes Inserted in Circular Cross-Section Conduits Running Full Geneva, , Switzerland : International Standards Organization (ISO). . Standard 5167–1
- Johnson , A. B. , Besant , R. W. and Schoenau , G. J. 1995 . Design of Multi-Coil Run-Around Heat Exchanger Systems for Ventilation Air Heating and Cooling . ASHRAE Transactions , 101 ( 2 ) : 967 – 978 .
- Judd , R. L. , Aftab , K. and Elbestawi , M. A. 1994 . Investigation of The Use of Heat Pipes for Machine Tool Spindle Bearing Cooling . International Journal of Machine Tools & Manufacture , 34 : 1031 – 1042 .
- McFarland , J. K. , Jeter , M. A. and Abdel-khalik , S. I. 1996 . Effect of a Heat Pipe on Dehumidification of a Controlled Air Space . ASHRAE Transactions , 102 ( 1 ) : 132 – 139 .
- Shah , R. K. and Giovannelli , A. D. 1988 . “ Heat Pipe Exchanger Design Theory. ” . In Heat Transfer Equipment Design 609 – 653 . New York : Hemisphere Publishing Corporation. .
- Wang , C. C. , Chen , P. Y. and Jang , J. Y. 1996 . Heat Transfer and Friction Characteristics of Convex-Louver Fin-and Tube Heat Exchangers . Experimental Heat Transfer , 9 : 61 – 78 .