145
Views
5
CrossRef citations to date
0
Altmetric
Original Articles

Performance of ASHRAE models in assessing pollutant dispersion from rooftop emissions

, &
Pages 72-79 | Received 03 Dec 2012, Accepted 08 Jul 2013, Published online: 08 Jan 2014

References

  • Arya , S. P.S. and Lape , J. F. 1990 . A comparative study of the different criteria for the physical modeling of buoyant plume rise in a neutral atmosphere . Atmospheric Environment , 24 : 289 – 95. .
  • ASHRAE . 1997 . ASHRAE Applications Handbook, Chapter 43, Building air intake and exhaust design. ASHRAE , Atlanta, GA.
  • ASHRAE . 1999 . ASHRAE Applications Handbook, Chapter 43, Building air intake and exhaust design. ASHRAE , Atlanta, GA.
  • ASHRAE . 2003 . ASHRAE Applications Handbook, Chapter 44, Building air intake and exhaust design. ASHRAE , Atlanta, GA.
  • ASHRAE . 2007 . ASHRAE Applications Handbook, Chapter 44, Building air intake and exhaust design. ASHRAE , Atlanta, GA.
  • ASHRAE . 2009 . ASHRAE Applications Handbook, Chapter 24, Airflow around buildings. ASHRAE , Atlanta, GA.
  • ASHRAE . 2011 . ASHRAE Applications Handbook, Chapter 45, Building air intake and exhaust design. ASHRAE , Atlanta, GA.
  • Briggs , G. A. 1984 . Plume rise and buoyancy effects in atmospheric science and power production . D. Randerson, ed. U.S. Department of Energy D.O.E./TIC-27601 (DE 84005177), Washington, DC
  • Chui , E. H. and Wilson , D. J. 1988 . Effects of varying wind direction on exhaust gas dilution . Journal of Wind Engineering and Industrial Aerodynamics , 31 : 87 – 104 .
  • Cimoreli , A. J. , Perry , S. G. , Venkatram , A. , Weil , J. C. , Paine , R. J. , Wilson , R. B. , Lee , R. F. , Peters , W. D. and Brode , R. W. 2005 . AERMOD: A dispersion model for industrial source applications. Part I: General model formulation and boundary layer characterisation . Applied Meteorology , 44 : 682 – 93 .
  • Gupta , A. , Stathopoulos , T. and Saathoff , P. J. 2012 . Evaluation of ASHRAE dilution models to estimate dilution from rooftop exhausts . ASHRAE Transactions , 118 : 200 – 18 .
  • Hajra , B. and Stathopoulos , T. 2012 . A wind tunnel study of the effect of downstream buildings on near-field pollutant dispersion . Building and Environment , 52 : 19 – 31 .
  • Hajra , B. , Stathopoulos , T. and Bahloul , A. 2011 . The effect of upstream buildings on near-field pollutant dispersion in the built environment. . Atmospheric Environment , 45 : 4930 – 40 .
  • Halitsky , J. 1963 . Gas diffusion near buildings . ASHRAE Transactions , 69 : 464 – 84 .
  • Holmes , N. S. and Morawska , L. 2006 . A review of dispersion modelling and its application to the dispersion of particles: An overview of different dispersion models available . Atmospheric Environment , 40 : 5902 – 28 .
  • Labovsky , J. and Jelemensky , L. 2011 . Verification of CFD pollution dispersion modelling based on experimental data . Journal of Loss Prevention in the Process Industries , 24 : 166 – 77 .
  • Petersen , R. L. , Carter , J. J. and Le-Compte , J. 2004 . Exhaust contamination of hidden versus visible air intakes . ASHRAE Transactions , 110 : 600 – 10 .
  • Saathoff , P. , Stathopoulos , T. and Dobrescu , M. 1995 . Effects of model scale in estimating pollutant dispersion near buildings . Journal of Wind Engineering and Industrial Aerodynamics , 54 : 549 – 59 .
  • Snyder , W. H. Guidelines for fluid modeling of atmospheric diffusion . EPA-600/8-81-009, Environmental Protection Agency, Office of Air Quality, Planning, and Standards, Research Triangle Park , NC
  • Stathopoulos , T. , Bahloul , A. and Hajra , B. Analytical evaluation of the dispersion of polluting emissions from building stacks . Research report (R-576), Institut de recherche Robert Sauvé en santé et en sécurité du travail , Montreal , , Canada
  • Touma , J. S. , Isakov , V. , Ching , J. and Seigneur , C. 2006 . Air quality modeling of hazardous pollutants: Current status and future directions . Air and Waste Management Association , 56 : 547 – 58 .
  • Wilson , D. J. 1979 . Flow patterns over flat-roofed buildings and application to exhaust stack design . ASHRAE Transactions , 85 ( pt. 2 ) : 284 – 95 .
  • Wilson , D. J. 1982 . Critical wind speeds for maximum exhaust gas re-entry from flush vents at roof level intakes . ASHRAE Transactions , 88 : 503 – 13 .
  • Wilson , D. J. and Chui , E. 1985 . Influence of exhaust velocity and wind incidence angle on dilution from roof vents . ASHRAE Transactions , 91 : 1693 – 706 .
  • Wilson , D. J. and Chui , E. 1987 . Effect of turbulence from upwind buildings on dilution of Exhaust gases . ASHRAE Transactions , 93 : 2186 – 197 .
  • Wilson , D. J. and Lamb , B. 1994 . Dispersion of exhaust gases from roof level stacks and vents on a laboratory building . Atmospheric Environment , 28 : 3099 – 111 .
  • Wilson , D. J. , Fabris , I. , Chen , J. and Ackerman , M. Adjacent building effects on laboratory fume hood exhaust stack design . ASHRAE Research Report 897, ASHRAE , Atlanta , GA

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.