References
- Alvarez‐Fernández , J. A. , Quirce , S. , Calleja , J. L. , Cuevas , M. and Losada , E. 1998 . Hypersensitivity pneumonitis due to an ultrasonic humidifier . Allergy , 53 ( 2 ) : 210 – 212 .
- Arundel , A. V. , Sterling , E. M. , Biggin , J. H. and Sterling , T. D. 1986 . Indirect health effects of relative humidity in indoor environments . Environmental Health Perspectives , 65 : 351
- Burge , H. A. , Solomon , W. R. and Boise , J. R. 1980 . Microbial prevalence in domestic humidifiers . Applied and Environmental Microbiology , 39 ( 4 ) : 840 – 4 .
- EPA . 2007 . BASE buildings test space HVAC characteristics: Humidification system types . http://www.epa.gov/iaq/base/pdfs/test_space_hvac_characteristics/thc-19.pdf
- Goldblith , S. A. and Wang , D. I.C. 1967 . Effect of microwaves on Escherichia coli and Bacillus subtilis . Applied and Environmental Microbiology , 15 ( 6 ) : 1371 – 5 .
- Green , G. H. 1985 . Indoor relative humidities in winter and the related absenteeism . ASHRAE Transactions , 91 ( 1 ) : 643 – 53 .
- International Electrotechnical Commission (IEC) . 1988 . Methods for measuring the performance of microwave ovens for household and similar purposes. , IEC Publication 705, International Electrotechnical Commission . Geneva, Switzerland.
- International Commission on Non-Ionizing Radiation Protection . 1998 . Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). International Commission on Non-Ionizing Radiation Protection . Health Physics , 74 ( 4 ) : 494 – 522 .
- Kang , Y. and Kato , S. 2013 . Thermal and non-thermal germicidal effects of microwave radiation on microbial agents . Indoor and Built Environment , doi: 10.1177/1420326X13490180.
- Katsui , N. , Nakata , H. , Sakamoto , M. , Nishikawa , F. and Kita , E. 1996 . Experimental study on the microbial contamination of evaporating-type humidifiers . The Society of Heating, Air-Conditioning and Sanitary Engineers of Japan (SHASE) , 61 : 37 – 44 . [in Japanese]
- Marinkovich , V. A. and Hill , A. 1975 . Hypersensitivity alveolitis . The Journal of the American Medical Association , 231 ( 9 ) : 944 – 7 .
- Shaw , C. Y. , Magee , R. J. , Shirtliffe , C. J. and Unligil , H. 1991 . Indoor air quality assessment in an office-library building: Part II-Test results . ASHRAE Transactions , 97 ( 2 ) : 136 – 45 .
- Shimotsu , T. , Yanagi , U. , Takatori , K. , Yoneda , M. , Harada , M. , Takase , Y. and Nakabayashi , T. 2010 . “ Study of microbial decontamination method in evaporative humidifier ” . In Proceedings of Contamination Control Vol. A08 , 73 – 88 . Tokyo, Japan
- Stout , J. E. , Best , M. G. and Yu , V. L. 1986 . Susceptibility of members of the family legionellaceae to thermal stress: Implications for heat eradication methods in water distribution systems . Applied and Environmental Microbiology , 52 ( 2 ) : 396 – 9 .
- Strindehag , O. , Josefsson , I. and Henningson , E. 1991 . Emission of bacteria from air humidifiers . Environment International , 17 ( 4 ) : 235 – 41 .
- Sung , M. , Kato , S. , Yanagi , U. , Kim , M. and Harada , M. 2011 . Disinfection performance of ultraviolet germicidal irradiation systems for the microbial contamination on an evaporative humidifier . HVAC&R Research , 17 ( 1 ) : 22 – 30 .
- Tyndall , R. L. , Lehman , E. S. , Bowman , E. K. , Milton , D. K. and Barbaree , J. M. 1995 . Home humidifiers as a potential source of exposure to microbial pathogens, endotoxins, and allergens . Indoor Air , 5 ( 3 ) : 171 – 8 .
- Woo , I. S. , Rhee , I. K. and Park , H. D. 2000 . Differential damage in bacterial cells by microwave radiation on the basis of cell wall structure . Applied and Environmental Microbiology , 66 : 2243 – 7 .