References
- Alaska Housing Finance Corporation. 2012. Alaska Retrofit Information System (ARIS). Alaska Housing Finance Corporation, Anchorage, AK.
- Anagnost, S.E. 2007. Sampling and Analysis of Indoor Microorganisms, Chapter 8, Wood in the built environment—Conditions for mold and decay. C.S. Yang and P.A. Heinsohn, eds. New York, NY: John Wiley & Sons.
- ASHRAE. 2009. 2009 ASHRAE Handbook—Fundamentals. Atlanta, GA: ASHRAE.
- Derome, D., and G. Desmarais. 2006. Exposure to condensation moisture of sheathing in retrofitted leaky wall assemblies. Journal of Architectural Engineering 12:72–82.
- Handegord, G.O.P. 1985. Prediction of the moisture performance of walls. ASHRAE Transactions 91(2):1501–8.
- International Code Council, Inc. 2010. 2009 International residential code® for one- and two-family dwellings. Country Club Hills, IL: International Code Council, Inc.
- Kane, R., and G. Titley. 1987. Thermal Insulation: Materials and Systems, ASTM STP 922, pp. 615–29, Case histories of moisture monitoring in residential walls. F.J. Powell and S.L. Matthew, eds. Philadelphia, PA: ASTM.
- Karagiozis, A.N., J. Lstiburek, and A. Desjarlais. 2007. Scientific analysis of vapor retarder recommendations for wall systems constructed in North America. Proceedings of Thermal Performance of the Exterior Envelopes of Whole Buildings X, Clearwater Beach, FL, December 2–7.
- Lstiburek, J., and J. Carmody. 1994 Moisture Control Handbook, Principles and Practices for Residential and Small Commercial Buildings. New York, NY: John Wiley and Sons.
- McFadden, T. 1989. Moisture accumulation in insulated walls in cold regions. Journal of Cold Regions Engineering 3:73–83.
- Sherwood, G.E. 1983. Condensation potential in high thermal performance walls—Cold winter climate. Research paper FPL 433, U.S. Department of Agriculture Forest Products Laboratory, Madison, WI.
- Spinu, M. 2012. Without compromise: balancing durable and energy-efficient buildings. The Construction Specifier . November: 36–53.
- Sterling, E., A. Arundel, and T. Sterling. 1985. Criteria for human exposure to humidity in occupied buildings. ASHRAE Transactions 91(1):611–22.
- Straube, J.D. 2001. The influence of low-permeance vapor barriers on roof and wall performance. Proceedings of Thermal Performance of Whole Buildings VIII, Clearwater Beach, FL, December 2–7.
- Straube, J., D. Onysko, and C. Schumacher. 2002. Methodology and design of field experiments for monitoring the hygrothermal performance of wood frame enclosures. Journal of Thermal Envelope and Building Science 26:123–51.
- Straube, J., R. Smith, and G. Finch. 2009. Spray polyurethane foam: The need for vapour retarders in above-grade residential walls. . University of Waterloo, Canada.
- Tsongas, G. 2009. Moisture Control in Buildings: The Key Factor in Mold Prevention, 2nd Ed. Chapter 13, Case studies of moisture problems in residences. H.R. Trechsel and M.T. Bomberg, eds. West Conshohocken, PA: ASTM.
- Viitanen, H. 1994. Factors affecting the development of biodeterioration in wooden constructions. Materials and Structures 27:483–93.
- Viitanen, H., and T. Ojanen. 2007. Improved model to predict mold growth in building materials. Proceedings of Thermal Performance of the Exterior Envelopes of Whole Buildings X, Clearwater Beach, FL, December 2–7.