82
Views
2
CrossRef citations to date
0
Altmetric
Original Articles

Pressurized planar electrochromatography as a supporting tool for qualitative toxicological chemical analysis with thin-layer chromatography and UV–Vis spectrometry

, , , , , , & show all

References

  • Jain, R.; Sherma, J. Planar Chromatography in Clinical Chemistry. In Encyclopedia of Analytical Chemistry; Meyers, R. A. Ed.; John Wiley & Sons Ltd: Chichester, 2000; 1583–1603 pp.
  • Ojanperä, I.; Nokua, J.; Vuori, E.; Sunila, P.; Sippola, E. Thin-Layer Chromatography and Mass Spectrometry for Screening of Biological Samples for Drugs and Metabolites. J. Planar Chromatogr. 1999, 12, 96–108.
  • Pfeifer, A. M.; Kovar, K.-A. Identification of LSD, MBDB, and Atropine in Real Samples with On-Line HPTLC-FTIR Coupling. J. Planar Chromatogr. 1995, 8, 388–392.
  • Poortman, A. J.; Lock, E. Analytical Profile of 4-Methylthioamphetamine (4-MTA), a New Street Drug. Forensic Sci. Int. 1999, 100, 221–233.
  • Ludányi, K.; Gömöry, A.; Klebovich, I.; Monostory, K.; Vereczkey, L.; Újszászy, K.; Vékey, K. Application of TLC-FAB Mass Spectrometry in Metabolism Research. J. Planar Chromatogr. 1997, 10, 90–96.
  • Wilson, I. D.; Morden, W. Advances in Application in the Use of HPTLC-MS-MS. J. Planar Chromatogr. 1996, 9, 84–91.
  • Spangenberg, B.; Seigel, A.; Kempf, J.; Weinmann, W. Forensic Drug Analysis by Means of Diode-Array HPTLC Using RF and UV Library Search. J. Planar Chromatogr. 2005, 18, 336–343.
  • Demme, U.; Arndt, C.; Dorn, M.; Werner, R. Application of Two-Dimensional High-Performance Thin-Layer Chromatography to Qualitative and Quantitative Toxicological–Chemical Analysis. J. Planar Chromatogr. 2014, 27, 299–314.
  • Ojanperä, I.; Ojansivu, R.-L.; Nokua, J.; Vuori, E. Comprehensive TLC Drug Screening in Forensic Toxicology: Comparison of Findings in Urine and Liver. J. Planar Chromatogr. 1999, 12, 38–41.
  • Benda, L.; Bălălău, D.; Guţu, C. M.; Ilie, M.; Baconi, D. L. Qualitative and Semiquantitative TLC Analysis of Certain Phenothiazines in Human Plasma. Farmacia 2009, 57, 542–548.
  • Isenschmid, D.; Levine, B. Cocaine. In The Clinical Toxicology Laboratory: Contemporary Practice of Poisoning Evaluation; Shaw, L. M., Ed.-in-Chief.; AACC Press: Washington, 2001, 97–112 pp.
  • Timcheh-Hariri, A.; Balali-Mood, M.; Sadeghi, M.; Lari, N.; Riahi-Zanjani, B. Comparison of ELISA and TLC Methods for the Morphine Detection in Urine of Drug Abusers. Iran. J. Toxicol. 2016, 10, 47–50.
  • Sadeg, N.; François, G.; Petit, B.; Dutertre-Catella, H.; Dumontet, M. Automated Liquid-Chromatographic Analyzer Used for Toxicology Screening in a General Hospital: 12 Months’ Experience. Clin. Chem. 1997, 43, 498–504.
  • Celiński, R.; Albert, M.; Olszowy, Z.; Kulikowska, J. A Case of Suicidal Poisoning with Cinnarizine. Probl. Forensic Sci. 2003, 55, 67–75.
  • Maurer, H. H. Systematic Toxicological Analysis Procedures for Acidic Drugs and/or Metabolites Relevant to Clinical and Forensic Toxicology and/or Doping Control. J. Chromatogr. B. 1999, 733, 3–25.
  • Drummer, O. H. Chromatographic Screening Techniques in Systematic Toxicological Analysis. J. Chromatogr. B. 1999, 733, 27–45.
  • Franke, J. P.; de Zeeuw, R. A. Solid-Phase Extraction Procedures in Systematic Toxicological Analysis. J. Chromatogr. B. 1998, 713, 51–59.
  • Polettini, A. Systematic Toxicological Analysis of Drugs and Poisons in Biosamples by Hyphenated Chromatographic and Spectroscopic Techniques. J. Chromatogr. B. 1999, 733, 47–63.
  • Gergov, M.; Boucher, B.; Ojanpera, I.; Vuori, E. Toxicological Screening of Urine for Drugs by Liquid Chromatography/Time-of-Flight Mass Spectrometry with Automated Target Library Search Based on Elementa Formulas. Rapid Commun. Mass Spectrom. 2001, 15, 521–526.
  • Lambert, W. E.; Meyer, E.; De Leenheer, A. P. Screening, Identification, and Quantitation of Benzodiazepines in Postmortem Samples by HPLC with Photodiode Array Detection. J. Anal. Toxicol. 1995, 19, 73–78.
  • de Zeeuw, R. A.; Hartstra, J.; Franke, J. P. Potential and Pitfalls of Chromatographic Techniques and Detection Modes in Substance Identification for Systematic Toxicological Analysis. J. Chromatogr. A. 1994, 674, 3–13.
  • Berezinka, H.; Dallakian, P.; Budzikiewicz, H. Thin-Layer Chromatography and Mass Spectromettry for Screening of Biological Samples for Drugs and Metabolites. J. Planar Chromatogr. 1999, 12, 96–108.
  • Nurok, D.; Koers, J. M.; Novotny, A. L.; Carmichael, M. A.; Kosiba, J. J.; Santini, R. E.; Hawkins, G. L.; Replogle, R. W. Apparatus and Initial Results for Pressurized Planar Electrochromatography. Anal. Chem. 2004, 76, 1690–1695.
  • Novotny, A. L.; Nurok, D.; Replogle, R. W.; Hawkins, G. L.; Santini, R. E. Results with an Improved Apparatus for Pressurized Planar Electrochromatography. Anal. Chem. 2006, 78, 2823–2831.
  • Dzido, T. H.; Mróz, J.; Jóźwiak, G. Application of a Horizontal DS Chamber to Planar Electrochromatography in a Closed System. J. Planar Chromatogr. 2004, 17, 404–410.
  • Dzido, T. H.; Płocharz, P. W.; Ślązak, P. Apparatus for Pressurized Planar Electrochromatography in Completely Closed System. Anal. Chem. 2006, 78, 4713–4721.
  • Płocharz, P. W.; Dzido, T. H.; Ślązak, P.; Jóźwiak, G.; Torbicz, A. Influence of Sample Application Mode on Performance of Pressurized Planar Electrochromatography in Completely Closed System. J. Chromatogr. A. 2007, 1170, 91–100.
  • Dzido, T. H.; Płocharz, P. W.; Ślązak, P.; Hałka, A. Progress in Planar Electrochromatography. Anal. Bioanal. Chem. 2008, 391, 2111–2118.
  • Chomicki, A.; Ślązak, P.; Dzido, T. H. Preliminary Results for 2-D Separation with High-Performance Thin-Layer Chromatography and Pressurized Planar Electrochromatography. Electrophoresis 2009, 30, 3718–3725.
  • Hałka, A.; Płocharz, P. W.; Torbicz, A.; Dzido, T. H. Reversed-Phase Pressurized Planar Electrochromatography and Planar Chromatography of Acetylsalicylic Acid, Caffeine and Acetaminophen. J. Planar Chromatogr. 2010, 23, 420–425.
  • Płocharz, P.; Klimek-Turek, A.; Dzido, T. H. Pressurized Planar Electrochromatography, High-Performance Thin-Layer Chromatography and High-Performance Liquid Chromatography – Comparison of Performance. J. Chromatogr. A. 2010, 1217, 4868–4872.
  • Polak, B.; Wojtanowski, K. K.; Ślązak, P.; Dzido, T. H. Separation of Some Aromatic Amino Acid Enantiomers with Pressurized Planar Electrochromatography and TLC. Chromatographia 2011, 73, 339–345.
  • Hałka-Grysińska, A.; Ślązak, P.; Torbicz, A.; Sajewicz, M.; Dzido, T. H. A Modified Device for Pressurized Planar Electrochromatography and Preliminary Results with On-Line Sample Application. Chromatographia 2013, 76, 1271–12790.
  • Dzido, T. H.; Łopaciuk, E.; Płocharz, P. W.; Chomicki, A.; Zembrzycka, M.; Frank, H. Equipment and Preliminary Results for Orthogonal Pressurized Planar Electrochromatography. J. Chromatogr. A. 2014, 1334, 149–155.
  • Gajos, R.; Łopaciuk, E.; Dzido, T. H. Influence of Some Operation Variables on Continuous Separation Process of Orthogonal Pressurized Planar Electrochromatography. J. Chromatogr. A. 2015, 1396, 131–139.
  • Polak, B.; Chomicki, A.; Wierzchowski, P.; Klimek-Turek, A. Influence of Some Variables on Separation of Diastereomeric FVDA-Amino Alcohol Derivatives in High-Performance Thin-Layer Chromatography and Pressurized Planar Electrochromatography Systems. Curr. Anal. Chem. 2016, 12, 335–348.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.