121
Views
0
CrossRef citations to date
0
Altmetric
Case Conference

Ventricular Fibrillation Simulated Electrocardiogram Artifact by a Deep Brain Stimulator

ORCID Icon, , & ORCID Icon
Pages 1115-1117 | Received 03 Jan 2023, Accepted 07 Mar 2023, Published online: 30 Mar 2023

References

  • Perlmutter JS, Mink JW. Deep brain stimulation. Annu Rev Neurosci. 2006;29:229–57. doi:10.1146/annurev.neuro.29.051605.112824.
  • Mayberg HS, Lozano AM, Voon V, McNeely HE, Seminowicz D, Hamani C, Schwalb JM, Kennedy SH. Deep brain stimulation for treatment-resistant depression. Neuron. 2005;45(5):651–60. doi:10.1016/j.neuron.2005.02.014.
  • Martin WA, Camenzind E, Burkhard PR. ECG artifact due to deep brain stimulation. Lancet. 2003;361(9367):1431. doi:10.1016/S0140-6736(03)13136-4.
  • Mruk M, Stroop R, Boergel J, Lang NM, Nakamura M, Lehrke R, Zawy Alsofy S. Neurostimulator-induced ECG artefacts: a systematic analysis. Clin Neurol Neurosurg. 2021;203:106557. doi:10.1016/j.clineuro.2021.106557.
  • Stelzer MA, Padanilam MS, Miller JJ, Foreman J, Golden K, Ahmed AS. Identifying and troubleshooting low-frequency artifacts mimicking atrial flutter caused by deep brain stimulator. HeartRhythm Case Rep. 2021;7(10):683–6. doi:10.1016/j.hrcr.2021.07.001.
  • Hockman CH, Mauck HP, Hoff EC. ECG changes resulting from cerebral stimulation: II. A spectrum of ventricular arrhythmias of sympathetic origin. Am Heart J. 1966;71(5):695–700. doi:10.1016/0002-8703(66)90322-X.
  • Carlson C, Devinsky O. The excitable cerebral cortex Fritsch G, Hitzig E. Uber die elektrische Erregbarkeit des Grosshirns. Arch Anat Physiol Wissen 1870;37:300-32. Epilepsy Behav. 2009;15(2):131–2. doi:10.1016/j.yebeh.2009.03.002.
  • Cooper IS, Riklan M, Amin I, Waltz JM, Cullinan T. Chronic cerebellar stimulation in cerebral palsy. Neurology. 1976;26(8):744–53. doi:10.1212/wnl.26.8.744.
  • Lozano AM, Lipsman N. Probing and regulating dysfunctional circuits using deep brain stimulation. Neuron. 2013;77(3):406–24. doi:10.1016/j.neuron.2013.01.020.
  • Gagnier JJ, Kienle G, Altman DG, Moher D, Sox H, Riley D. The CARE guidelines: consensus-based clinical case reporting guideline development. Glob Adv Health Med. 2013;2(5):38–43. doi:10.7453/gahmj.2013.008.
  • Knight BP, Pelosi F, Michaud GF, Strickberger SA, Morady F. Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia. N Engl J Med. 1999;341(17):1270–4. doi:10.1056/NEJM199910213411704.
  • Neumann W-J, Memarian Sorkhabi M, Benjaber M, Feldmann LK, Saryyeva A, Krauss JK, Contarino MF, Sieger T, Jech R, Tinkhauser G, et al. The sensitivity of ECG contamination to surgical implantation site in brain computer interfaces. Brain Stimul. 2021;14(5):1301–6. doi:10.1016/j.brs.2021.08.016.
  • Jacob S, Panaich SS, Maheshwari R, Haddad JW, Padanilam BJ, John SK. Clinical applications of magnets on cardiac rhythm management devices. Europace. 2011;13(9):1222–30. doi:10.1093/europace/eur137.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.