1,432
Views
4
CrossRef citations to date
0
Altmetric
Technical Papers

Testing equivalency of an alternative method based on portable FTIR to the European Standard Reference Methods for monitoring emissions to air of CO, NOx, SO2, HCl, and H2O

, , , , , , & show all
Pages 1011-1019 | Received 23 Feb 2015, Accepted 27 May 2015, Published online: 25 Jul 2015

References

  • Bureau International des Poids et Measures. 2006. Le Système International de’Unités, 8th ed. www.bipm.org/
  • Coleman, M.D., R.A. Robinson, M. Williams, R. Elliott, M. Clack, and A. Curtis. 2010. Demonstrating equivalence of an alternative method for SO2 emissions monitoring using NPL’s Stack Simulator facility. PPChem. 12(4):218.
  • Coleman, M.D., R.A. Robinson, M.B. Williams, M.J. Clack, and D.M. Butterfield. 2013. State of UK emissions monitoring of stacks and flues: An evaluation of proficiency testing data for SO2, NO and particulates. Accred. Qual. Assur. 18:517–24. doi:10.1007/s00769-013-1011-x
  • Comité Européen de Normalisation. 1999. Guide to the Expression of Uncertainty in Measurement. ENV 13005. https://www.cen.eu/
  • Comité Européen de Normalisation. 2004. Stationary Source Emissions—Quality Assurance of Automated Measuring Systems. EN 14181. https://www.cen.eu/
  • Comité Européen de Normalisation. 2005a. Stationary Source Emissions—Determination of Mass Concentration of Sulphur Dioxide—Reference Method. EN 14791. https://www.cen.eu/
  • Comité Européen de Normalisation. 2005b. Stationary Source Emissions—Determination of the Water Vapour in Ducts. EN 14790. https://www.cen.eu/
  • Comité Européen de Normalisation. 2005c. Stationary Source Emission—Intralaboratory Validation Procedure for an Alternative Method Compared to a Reference Method. CEN/TS 14793. https://www.cen.eu/
  • Comité Européen de Normalisation. 2006. Stationary Source Emissions—Determination of the Mass Concentration of Carbon Monoxide (CO). Reference Method: Non-Dispersive Infrared Spectrometry. EN 15058. https://www.cen.eu/
  • Comité Européen de Normalisation. 2007a. Air Quality—Certification of Automated Measuring Systems. EN 15267-3. https://www.cen.eu/
  • Comité Européen de Normalisation. 2007b. Air Quality—Measurement of Stationary Source Emissions—Requirements for Measurement Sections and Sites and for the Measurement Objective, Plan and Report. EN 15259. https://www.cen.eu/
  • Comité Européen de Normalisation. 2007c. Stationary Source Emissions—Determination of Mass Concentration of Nitrogen Oxides (NOx)—Reference Method: Chemiluminescence. EN 14792. https://www.cen.eu/
  • Comité Européen de Normalisation. 2010. Stationary Source Emissions—Determination of Mass Concentration of Gaseous Chlorides Expressed as HCl. Standard Reference Method. EN 1911. https://www.cen.eu/
  • Environment Agency for England. 2012a. Personnel Competency Standard for Manual Stack Emission Monitoring, version 8.1. https://www.gov.uk/
  • Environment Agency for England. 2012b. Technical Guidance Note M22, Measuring Stack Gas Emissions using FTIR Instruments. version 3. https://www.gov.uk/
  • European Commission. 2000. Directive 2000/76/EC of the European Parliament and of the Council of 4 December 2000 on the Incineration of Waste. Off. J. Eur. Commun. L332:91–111.
  • European Commission. 2001. Directive 2001/80/EC of the European Parliament and of the Council of 23 October 2001 on the Limitation of Emissions of Certain Pollutants into the air from Large Combustion Plants. Off. J. Eur. Commun. L309:1–21.
  • European Commission. 2010. Directive 2010/75/EU of the European Parliament and of the Council of 24 November 2010 on Industrial Emissions (Integrated Pollution Prevention and Control). Off. J. Eur. Commun. L334:17–119.
  • European Commission. 2006. Regulation (EC) No 166/2006 of the European Parliament and of the Council of 18th January 2006 Concerning the Establishment of a European Pollutant Release and Transfer Register and Amending Council Directives 91/689/EEC and 96/61/EC. Off. J. Eur. Union L33:1–17.
  • International Organization for Standardization. 1994a. Accuracy (Trueness and Precision) of Measurement Methods and Results—Part 2: Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method. ISO 5725-2. http://www.iso.org
  • International Organization for Standardization. 1994b. Accuracy (Trueness and Precision) of Measurement Methods and Results—Part 6: Use in Practice of Accuracy Values. ISO 5725-6. http://www.iso.org
  • International Organization for Standardization. 2002. Air Quality—Evaluation of the Suitability of a Measurement Procedure by Comparison with a Required Measurement Uncertainty. ISO 14956. http://www.iso.org
  • International Organization for Standardization. 2005. General Requirements for the Competence of Testing and Calibration Laboratories. ISO 17025. http://www.iso.org
  • MCERTS. 2014. MCERTS Certified Products. http://www.siraenvironmental.com/UserDocs/mcerts/MCERTSCertifiedProductsCEMS.pdf (accessed October 2014).
  • United Nations Economic Commission for Europe. 1979. Convention on Long-range Transboundary Air Pollution. Geneva, Switzerland: UNECE.
  • United Nations. 2003. Protocol on Pollutant Release and Transfer Registers. Kiev, Ukraine, May 21.
  • Williams, M.B. 2011. Gas Measurement Proficiency Testing Scheme Round 2. NPL Report AS57. http://www.npl.co.uk/publications

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.