3,017
Views
11
CrossRef citations to date
0
Altmetric
Technical Papers

Experimental and simulation study on bake-out with dilution ventilation technology for building materials

, , &
Pages 1098-1108 | Received 19 Feb 2016, Accepted 06 Jun 2016, Published online: 22 Jun 2016

References

  • Brinke, J., S. Selvin, A.T. Hodgson, W.J. Fisk, M.J. Mendell, C.P. Koshland, and J.M. Daisey. 1998. Development of new VOC exposure metrics and their relationship to “sick building syndrome” symptoms. Indoor Air 8:140–52. doi:10.1111/ina.1998.8.issue-3
  • Chan, D., C. Tam, and A.P. Jones. 2007. An inter-comparison of VOC types and distribution in different indoor environments in a university campus. Indoor Built Environ. 16:376–82. doi:10.1177/1420326X07081094
  • Choi, D.W., K.W. Moon, S.H. Byeon, E.I. Lee, D.G. Sul, and J.H. Lee. 2009. Indoor volatile organic compounds in atopy patients’ houses in South Korea. Indoor Built Environ. 18:144–54.
  • Cui, X.L. 2010. Study and application of TVOC content in indoor air by capillary gas chromatography. Qiingdao University, Qiingdao, China.
  • Du, R.G., Qi Bing, and H.H. Guo. 2005. Detection of benzene series and TVOC in indoor air. Zhejiang Chem. Eng. 36(8):29–31.
  • Edwards, R.D., J.K. Jurvelin, K. Koistinen Saarela, and M. Jantunen. 2001. VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki Finland. Atmos. Environ. 35:4829–41. doi:10.1016/S1352-2310(01)00271-0
  • Etkin, D.S. 1996. Volatile organic compounds in indoor environments. Arlington, VA: Cutter Information Corp.
  • Follin, T. 1997. Airing out pollutions. Proceedings of the Healthy Buildings/ IAQ’97, vol. 3, Healthy Buildings/IAQ’97, Washington, DC, 3:353–56.
  • Girman, J.R., L.E. Alevantis, G.C. Kulasingam, M.X. Petreas, and L.M. Webber. 1989. The bake-out of an office building: A case study. Environ. Int. 15:449–53. doi:10.1016/0160-4120(89)90061-5
  • Girman, J.R. 1989. Volatile organic compounds and building bake-out. In Problem building: Building-associated illness and the sick building syndrome, ed. J.E. Cone and M.J. Hodgson, 695–712. Philadelphia, PA: Hanley & Belfus. doi:10.1177/014362448901000305
  • Hicks, J., K. Worl, and K. Hall. 1990. Building bake-out during commissioning. Proc Indoor Air 90, Toronto, Canada, 5th International Conference on Indoor Air Quality and Climate 3:413–18.
  • Hodgson, M., H. Levin, and P. Wolkoff. 1994. Volatile organic compounds and indoor air. J. Allergy Clin. Immunol. 94:296–303. doi:10.1053/ai.1994.v94.a56008
  • Kang, D.H., D.H. Choi, and S.M. Lee. 2010. Effect of bake-out on reducing VOC emissions and concentrations in a residential housing unit with a radiant floor heating system. Building Environ. 45(8):1816–25. doi:10.1016/j.buildenv.2010.02.010
  • Kang, D.H., D.H. Choi, S.S. Kim, M.Y. Park, M.S. Yeo, and K.W. Kim. 2006. Ventilation strategies for effective bake-out in new apartment buildings. Healthy Building 4:321–24.
  • Katsoyiannis, A., P. Leva, and D. Kotzias. 2008. VOC and carbonyl emissions from carpets: a comparative study using four types of environmental chambers. J. Hazard. Mater. 152:669–76. doi:10.1016/j.jhazmat.2007.07.058
  • Kim, S., Y.K. Choi, K.W. Park, and J.T. Kim. 2010. Test methods and reduction of organic pollutant compound emissions from wood-based building and furniture materials. Bioresource Technol. 101:6562–68. doi:10.1016/j.biortech.2010.03.059
  • Kim, S., and H.J. Kim. 2005. Comparison of formaldehyde emission from building finishing materials at various temperatures in under heating system; ONDOL. Indoor Air 15(5):317–25. doi:10.1111/ina.2005.15.issue-5
  • Kim, S., J.A. Kim, J.Y. An., H.J. Kim, and S.J. Moon. 2006. Development of a test method using a VOC analyzer to measure VOC emission from adhesives for building materials. J. Adhesion Sci. Technol. 20(15):1783–99. doi:10.1163/156856106779024445
  • Kim, S.Y., K.Y. Kim, Y.S. Han, and J.W. Koo. 2010. Variation of indoor air quality in a new apartment building by bake-out. Int. J. Environ. Res. 4(2):263–70.
  • Kondo, Y., S. Kato, and S. Mulakami. 1999. Physical model and numerical analysis of VOCS emission from building materials (part2) prediction of short term and long term VOCS emission based on micro-macro model. Summaries of Technical Papers of Annual Convention AIJ: 125–126.
  • Lee, C.S., F. Haghighat, and W.S. Ghaly. 2005. A study on VOC source and sink behavior in porous building materials–analytical model development and assessment. Indoor Air 15(3):183–96. doi:10.1111/ina.2005.15.issue-3
  • Levin, H. 1989. Building materials and indoor air quality. In: Cone, J.E., Hodgson, M.J. (Eds.), Problem Buildings: Building-Associated Illness and the Sick Building Syndrome. Hanley & Belfus, Inc., Philadelphia, PA. 667–69. doi:10.1177/014362448901000305
  • Li, J., Y. Liu, Y. Lu, B. Xie, and S. Deng. 2005. Improve of IAQ by a new bake-out method based on chamber tests. 6th Int, Conf. on Indoor Air Quality and Climate, Beijing, China. Indoor Air 3075–79.
  • Li, M. 2009. Actuality and development of floor radiation heating system of hot water. Forestry sci. Technol. Inform. 2:72–73.
  • Liu, J., J. Li, Y. Lv, and J.R. Zhang. 2007. Study on CFD numerical simulation on technological process of bake out method coupled with intermittent ventilation. J. Environ. Sci. 33(4):67–69.
  • Lu, H.X., Q.Y. Cai, S. Wen, Y.G. Chi, S.J. Guo, G.Y. Sheng, J.M. Fu, and A. Katsoyiannis. 2010. Carbonyl compounds and BTEX in the special rooms of hospital in Guangzhou, China. J. Hazard. Mater. 178:673–79.
  • Lu, Y., J. Liu, Y. Hiroshi, B.N. Lu, and A.X. Jiang. 2012. Use of Biotechnology coupled with Bake-out Exhaust to Remove Indoor VOC. Indoor and Built Environment. 21(6):741–48. doi:10.1177/1420326X11428342
  • Lu, Y., J. Liu, B.N. Lu, A.X. Jiang, J.R. Zhang, B. Xie, J. Li, and L. Zhang. 2007. Numerical value research on bake-out technology with dilution ventilation for building materials. Proc. Building Simulation 2007 907–11.
  • Lu, Y., J. Liu, B.N. Lv, A.X. Jiang, and C.L. Wan. 2010. Study on the removal of indoor VOCs using biotechnology. J. Hazard. Mater. 182(1–3):204–9. doi:10.1016/j.jhazmat.2010.06.016
  • Nozaki, A., K. Iikura, and S. Yoshizaw. 2000. Effects of bake out as a source control technique for indoor chemical substances (part1). J. Architect. Plan. Environ. Eng. 530:61–66.
  • Offerman, F.J., S.A. Loiselle, and G. Arbor. 1993. Indoor contaminant emission rates before and after a building bake-out. Proceedings of the Sixth International Conference on Indoor Air Quality and Climate 6:147–50.
  • Park, E.Y., D.H. Kang, D.H. Choi, S.M. Lee, Y.S. Min, J.H. An, M.S. Yeo, and K.W. Kim. 2007. Comparison of ventilation strategies during bake-out in winter at newly built apartment buildings. 6th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings, Sendai, Japan, October 28–31.
  • Qin, J.S., and P.H. Dang. 2004. Indoor environmental pollution hazards. Chongqing Building 4:55–57.
  • Shuangxiu Li. 2015. Indoor air quality assessment and purification research. Qingdao University of Science & Technology, Qingdao, China.
  • Saarela, K., T. Tirkkonen, J. Laine-Ylijoki, J. Jurvelin, M.J. Nieuwenhuijsen, and M. Jantunen. 2003. Exposure of population and microenvironmental distributions of volatile organic compound concentrations in the EXPOLIS study. Atmos. Environ. 37:5563–75. doi:10.1016/j.atmosenv.2003.09.031
  • Song, G.S. 2003. Prevention and Cure Guide of Indoor Environment Pollution. Beijing, China: Mechanical Industry Press.
  • Steeman, H.J., M.V. Belleghem, A. Janssens, and M.D. Paepe. 2009. Coupled simulation of heat and moisture transport in air and porous materials for the assessment of moisture related damage. Building Environ. 44:2176e84. doi:10.1016/j.buildenv.2009.03.016
  • Tao, G., and C. Liang. 2008. Analysis on development tendency of domestic and global plasticizer market. Plastics Sci. Technol. 36(6):78–81.
  • Tuomainen, M., A.L. Pasanen, and A. Tuomainen. 2001. Usefulness of the Finnish classification of indoor climate, construction and finishing materials: Comparison of indoor climate between two new blocks of flats in Finland. Atmos. Environ. 35(2):305–13. doi:10.1016/S1352-2310(00)00157-6
  • Van der Wal, J.F., A.W. Hoogeveen, and P. Wouda. 1997. The influence of temperature on the emission of volatile organic compounds from PVC flooring, carpet, and paint. Indoor Air 7(3):215–21. doi:10.1111/ina.1997.7.issue-3
  • Wang, K. 2004. Study on Measurement and Estimate and Control of Indoor Pollutants. Ph.D. dissertation, Harbin Inst. Technol, China.
  • Wang, L.X., B. Zhao, and C. Liu. 2010. Indoor SVOC pollution in China: A review. Chin. Sci. Bull. 55(15):1469–1478. doi:10.1007/s11434-010-3094-7
  • Wieslander, G., D. Norbäck, and C. Edling. 1997. Airway symptoms among house painters in relation to exposure to volatile organic compounds (VOCs)—A longitudinal study. Ann. Occup. Hyg. 41(2):155–66. doi:10.1093/annhyg/41.2.155
  • Wiglusz, R., E. Sitko G. Nikel, I. Jarnuszkiewicz, and B. Igielska. 2002. The effect of temperature on the emission of formaldehyde and volatile organic compounds (VOCs) from laminate flooring e case study. Building Environ. 37:41–47. doi:10.1016/S0360-1323(00)00091-3
  • World Health Organization. 2002. Department of Protection of the Human Environment, healthy environments for children: Initiating an alliance for action. Geneva, Switzerland: World Health Organization.
  • Wu, Q. 2001. Volatile organic compounds pollution. Chem. Teaching 7:17–18.
  • Yang, X.D., Q.Y. Chen, and P.M. Bluyssen. 1998. Prediction of short-term and long-term volatile organic compound emissions from SBR bitumen-backed carpet under different temperatures. ASHRAE Trans. 104:1297–308.
  • Yang, X.M., and G. Wu. 2006. Present situation and development of low-temperature water floor radiant heating system in China. J. Zhengzhou Univ. Light Ind. Nat. Sci. Ed. 21(4):54–57.
  • Yang, S., Q. Chen, and P.M. Bluyssen. 1998. Prediction of short-term and long-term VOC emissions from SBR bitumen-backed carpet under different temperatures. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
  • Zhang, Y., X. Luo, X. Wang, K. Qian, and R. Zhao. 2007. Influence of temperature on formaldehyde emission parameters of dry building materials. Atmos. Environ. 41(15):3203–16. doi:10.1016/j.atmosenv.2006.10.081
  • Zhang, Y., and Y. Xu. 2003. Characteristics and correlations of VOC emissions from building materials. Int. J. Heat Mass Transfer 46(25):4877–83. doi:10.1016/S0017-9310(03)00352-1
  • Zhou, D.G., and S.G. Han. 1997. Effect of temperature on emission of formaldehyde from flake board. Architecture Manmade Plane 4:3–8.
  • Zhu, T., J. Hao, and Z. Zhou. 2002. Present situation, formative causes and countermeasures of indoor air pollution in China. Technol. Equip. Environ. Pollut. Control 3(10):14–18.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.