1,126
Views
1
CrossRef citations to date
0
Altmetric
Article

Experimental temperature evaluation during a robotized bone drilling process

, , , &
Pages 117-125 | Received 01 Nov 2022, Accepted 14 Dec 2022, Published online: 30 Dec 2022

References

  • Timon C, Keady C. Thermal osteonecrosis caused by bone drilling in orthopedic surgery: a literature review. Cureus. 2019;11(7):e5226.
  • Zhang Y, Xu L, Wang C, et al. Mechanical and thermal damage in cortical bone drilling in vivo. Proc Inst Mech Eng H. 2019;233(6):621–635.[Mismatch]
  • Akhbar MFA, Sulong AW. Surgical drill bit design and thermomechanical damage in bone drilling: a review. Ann Biomed Eng. 2021;49(1):29–56.
  • Feldmann A, Wandel J, Zysset P. Reducing temperature elevation of robotic bone drilling. Med Eng Phys. 2016;38(12):1495–1504.
  • Shu L, Bai W, Shimada T, et al. Thermographic assessment of heat-induced cellular damage during orthopedic surgery. Med Eng Phys. 2020;83:100–105.
  • Pazarci O, Torun Y, Ozturk A, et al. Comparative study of different drills for bone drilling: a systematic approach. Malays Orthop J. 2020;14(2):83–89.
  • Augustin G, Davila S, Mihoci K, et al. Thermal osteonecrosis and bone drilling parameters revisited. Arch Orthop Trauma Surg. 2008;128(1):71–77.
  • Chen Y, Hsiao C, Ciou J, et al. Effects of implant drilling parameters for pilot and twist drills on temperature rise in bone analog and alveolar bones. Med Eng Phys. 2016;38(11):1314–1321.
  • Fernandes M, Fonseca E, Jorge R, et al. Effect of drill speed on the strain distribution during drilling of bovine and human bones. J Biomech Eng. 2018;2(5):69–74.
  • Hou Y, Li C, Ma H, et al. An experimental research on bone drilling temperature in orthopaedic surgery. TOMSJ. 2015;9(1):178–188.
  • Lughmani W, Bouazza-Marouf K, Ashcroft I. Drilling in cortical bone: a finite element model and experimental investigations. J Mech Behav Biomed Mater. 2015;42:32–42.
  • Staroveski T, Brezak D, Udiljak T. Drill wear monitoring in cortical bone drilling. Med Eng Phys. 2015;37(6):560–566.
  • Yen P, Ho T. Shared control for a handheld orthopedic surgical robot. IEEE Robot. Autom. Lett. 2021;6(4):8394–8400.
  • Welcome BM, Gilmer BB, Lang SD, et al. Comparison of manual hand drill versus an electric dual-motor drill for bedside craniotomy. Interdiscip Neurosurg: Adv Tech Case Manag. 2021;23:100928.
  • SMARTdrill 6.0 Now Available for Orthopedic Surgery, https://www.prnewswire.com/news-releases/smartdrill-6-0-now-available-for-orthopedic-surgery-300809777.html.
  • IntelliSense Drill Technology, https://www.mcginleyorthopedicinnovations.com/.
  • Louredo M, Diaz I, Gil J. DRIBON: a mechatronic bone drilling tool. Mechatronics. 2012;22(8):1060–1066.
  • Gil J, Díaz I, Accini F. Inferring material properties in robotic bone drilling processes. Acta Bioeng Biomech. 2019;21(3):109–118.
  • Jamil M, Rafique S, Khan AM, et al. Comprehensive analysis on orthopedic drilling: a state-of-the-art review. Proc Inst Mech Eng H. 2020;234(6):537–561.[Mismatch]
  • Akhbar MFA, Yusoff AR. Drilling of bone: effect of drill bit geometries on thermal osteonecrosis risk regions. Proc Inst Mech Eng H. 2019;233(2):207–218.[Mismatch]
  • Hou Y, Li C, Ma H, et al. A theoretical analysis on bone drilling temperature field of superhard drill. TOMEJ. 2016;10(1):109–125.
  • You F, Li J, Cui H, et al. Study of the influence of models on the drilling temperature of bone measured by thermocouples. Adv Compos Lett. 2020;29:2633366X2092140–2633366X2092149.
  • Ben-Zvi Y, Reznikov N, Shahar R, et al. 3D architecture of trabecular bone in the porcine mandible and femur: inter-trabecular angle distributions. Front Mater. 2017;4:29.
  • Sarparast M, Ghoreishi M, Jahangirpoor T, et al. Modelling and optimization of temperature and force behaviour in high speed bone drilling. Biotechnol Biotechnol Equip. 2019;33(1):1616–1625.
  • Sarparast M, Ghoreishi M, Jahangirpoor T, et al. Experimental and finite element investigation of high‑speed bone drilling: evaluation of force and temperature. J Braz Soc Mech Sci. 2020;42:349.
  • Islam M, Kamarrudin N, Daud R, et al. Temperature measurement methods in an experimental setup during bone drilling: a brief review on the comparison of thermocouple and infrared thermography. J. Phys.: Conf. Ser. 2021;2129(1):012096. ICMProTech 2021
  • Boiadjiev T, Boiadjiev G, Delchev K, et al. Far cortex automatic detection aimed for partial or full bone drilling by a robot system in orthopaedic surgery. Biotechnol Biotechnol Equip. 2017;31(1):200–205.
  • Boiadjiev T, Boiadjiev G, Delchev K, et al. Feed rate control in robotic bone drilling process. Proc Inst Mech Eng H. 2021;235(3):273–280.[Mismatch]
  • Feldmann A, Zysset P. Experimental determination of the emissivity of bone. Med Eng Phys. 2016;38(10):1136–1138.
  • Augustin G, Davila S, Udiljak T, et al. Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report. Arch Orthop Trauma Surg. 2009;129(5):703–709.
  • Shakouri E, Sadeghi MH, Maerefat M, et al. Experimental and analytical investigation of the thermal necrosis in high-speed drilling of bone. Proc Inst Mech Eng H. 2014;228(4):330–341.[Mismatch]
  • Niehues SM, Elezkurtaj S, Bresssem KK, et al. Evaluation of potential tissue heating during percutaneous drill-assisted bone sampling in an in vivo porcine study. Skeletal Radiol. 2022;51(4):829–836.[Mismatch]
  • Augustin G, Zigman T, Davila S, et al. Cortical bone drilling and thermal osteonecrosis. Clin Biomech (Bristol, Avon). 2012;27(4):313–325.
  • Wang W, Shi Y, Yang N, et al. Experimental analysis of drilling process in cortical bone. Med Eng Phys. 2014;36(2):261–266.
  • Boiadjiev T, Boiadjiev G, Delchev K, et al. Orthopedic bone drilling robot ODRO: basic characteristics and areas of applications. In Latest developments in medical robotics systems. IntechOpen. 2021, p. 1–21.