1,757
Views
0
CrossRef citations to date
0
Altmetric
Research Article

Performance analysis of air curtains on indoor environment and dehumidification energy consumption in a low humidity plant

, & ORCID Icon
Pages 1648-1663 | Received 03 Jan 2022, Accepted 29 Jun 2022, Published online: 09 Jul 2022

References

  • Alipourtarzanagh, E., A. Chinnici, G. J. Nathan, and B. B. Dally. 2020. “Experimental Investigation on the Influence of an Air Curtain on the Convective Heat Losses from Solar Cavity Receivers under Windy Condition.” AIP Conference Proceedings Daegu, South Korea. 080001.
  • ANSYS. 2013. “ANSYS Fluent 14.0: Theory Guide.” Canonsburg: Ansys Inc, in Chinese.
  • Blocken, B. 2015. “Computational Fluid Dynamics for Urban Physics: Importance, Scales, Possibilities, Limitations and ten Tips and Tricks Towards Accurate and Reliable Simulations, Build.” Environment 91: 219–245.
  • Chen, Y.-G. 2009. “Parametric Evaluation of Refrigerated Air Curtains for Thermal Insulation.” International Journal of Thermal Sciences 48 (10): 1988–1996. doi:10.1016/j.ijthermalsci.2009.03.003
  • Deo, R. C., G. J. Nathan, and J. Mi. 2007. “Comparison of Turbulent Jets Issuing from Rectangular Nozzles with and without Sidewalls.” Experimental Thermal and Fluid Science 32 (2): 596–606. doi:10.1016/j.expthermflusci.2007.06.009.
  • Duan, R., and J. Liu. 2020. “Comparative Study on pollution-block Performance of ceiling-supply Air Curtain System for Commercial Building Entrance”. Building Simulation Conference Proceedings Rome, Italy.650–656.
  • Foster, A. M., M. J. Swain, R. Barrett, P. D’Agaro, L. P. Ketteringham, and S. J. James. 2007. “Three-dimensional Effects of an Air Curtain Used to Restrict Cold Room Infiltration.” Applied Mathematical Modelling 31 (6): 1109–1123. doi:10.1016/j.apm.2006.04.005.
  • GB 50009-2012. 2012. Load code for the design of building structures. Beijing: National Standards of the People’s Republic of China, in Chinese. 30–62 .
  • Geng, F., C. Gui, Y. Wang, F. Zhou, S. Hu, and G. Luo. 2019. “Dust Distribution and Control in A Coal Roadway Driven by an Air Curtain System: A Numerical Study.” Process Safety and Environmental Protection 121: 32–42. doi:10.1016/j.psep.2018.09.005.
  • Gil-Lopez, T., J. Castejon-Navas, M. A. Galvez-Huerta, and P. G. O’Donohoe. 2014. “Energetic, Environmental and Economic Analysis of Climatic Separation by Means of Air Curtains in Cold Storage Rooms.” Energy and Buildings 74: 8–16. doi:10.1016/j.enbuild.2014.01.026.
  • Goubran, S., D. Qi, W. F. Saleh, L. (Leon) Wang, and R. Zmeureanu. 2016. Experimental Study on the Flow Characteristics of Air Curtains at Building Entrances. 105 225–235. doi:10.1016/j.buildenv.2016.05.037
  • Guyonnaud, L., C. Solliec, M. Dufresne de Virel, and C. Rey. 2000. “Design of Air Curtains Used for Area Confinement in Tunnels.” Experiments in Fluids 28 (4): 377–384. doi:10.1007/s003480050397.
  • Huang, Y. 2005. “Numerical Simulation of Flow-field around the Building Based on FLUENT”. Master Thesis. Huazhong University of Science and Technology, in Chinese.
  • JB/T 9067-1999. 1999. “Air Curtain.” S. Beijing: National Standards of the People’s Republic of China, in Chinese.
  • Jiang, Y., D. Alexander, H. Jenkins, R. Arthur, and Q. Y. Chen. 2003. “Natural Ventilation in Buildings: Measurement in a Wind Tunnel and Numerical Simulation with large-eddy Simulation.” Journal of Wind Engineering and Industrial Aerodynamics 91 (3): 331–353. doi:10.1016/S0167-6105(02)00380-X.
  • Li, S. B. “Empirical Formula of Temperature and Saturated Humidity Ratio, HV&AC.” 2003. 112–113.
  • Liu, F. R. 2006. “Conversion between Mass Flow Rate of Evaporating Water and Heat Power of Steam Boilers.” China Special Equipment Safety 22: 63–68.
  • Liu, J., and J. Niu. 2016. “CFD Simulation of the Wind Environment around an Isolated high-rise Building: An Evaluation of SRANS.” Building and Environment 96: 91–106. doi:10.1016/j.buildenv.2015.11.007.
  • Liu, Y., and H. L. Wang. 2020. “Exploration of energy-saving Design of HVAC in Industrial Plants.” Plant Maintenance Engineering 20: 179–181.
  • Navaz, H. K., B. S. Henderson, R. Faramarzi, A. Pourmovahed, and F. Taugwalder. 2005. “Jet Entrainment Rate in Air Curtain of Open Refrigerated Display Cases.” International Journal of Refrigeration 28 (2): 267–275. doi:10.1016/j.ijrefrig.2004.08.002.
  • P4450E-1996. 1996. Recommendations for Loads on Building. Tokyo: Architectural Institute of Japan, in Japanese.
  • Rai, A., J. Sun, and S. A. Tassou. 2019. Three-dimensional Investigation on the Positioning of Air Curtain on Its Effectiveness in Refrigerated Vehicles Used for Food Distribution. 224–231. Energy Procedia.
  • Ramponi, R., and B. Blocken. 2012. “CFD Simulation of cross-ventilation for a Generic Isolated Building: Impact of Computational Parameters.” Building and Environment 53: 34–48. doi:10.1016/j.buildenv.2012.01.004.
  • Shen, X., G. Zhang, and B. Bjerg. 2012. “Comparison of Different Methods for Estimating Ventilation Rates through Wind Driven Ventilated Buildings.” Energy and Buildings 54: 297–306. doi:10.1016/j.enbuild.2012.07.017.
  • Tominaga, Y., A. Mochida, R. Yoshie, H. Kataoka, T. Nozu, M. Yoshikawa, and T. Shirasawa. 2008. “AIJ Guidelines for Practical Applications of CFD to Pedestrian Wind Environment around Buildings.” Journal of Wind Engineering and Industrial Aerodynamics 96 (10–11): 1749–1761. doi:10.1016/j.jweia.2008.02.058.
  • Toparlar, Y., B. Blocken, B. Maiheu, and G. J. F. van Heijst. 2017. “A Review on the CFD Analysis of Urban Microclimate.” Renewable Sustainability Energy Review 80: 1613–1640.
  • Wang, L., and Z. Zhong. 2014. “An Approach to Determine Infiltration Characteristics of Building Entrance Equipped with Air Curtains.” Energy and Buildings 75: 312–320. doi:10.1016/j.enbuild.2014.02.020.
  • Yang, S. 2019. Wind effects on air curtain performance at building entrances. Building and Environment. 13
  • Yin, S., W. Nie, Q. Liu, and Y. Hua. 2019. “Transient CFD Modelling of space-time Evolution of Dust Pollutants and air-curtain Generator Position during Tunneling.” Journal of Cleaner Production 239: 117924. doi:10.1016/j.jclepro.2019.117924.
  • Yu, L.-X., F. Liu, T. Beji, M.-C. Weng, and B. Merci. 2018. Experimental study of the effectiveness of air curtains of variable width and injection angle to block fire-induced smoke in a tunnel configuration 134: 13–26. doi:10.1016/j.ijthermalsci.2018.07.044
  • Zhao, R. 2009. Air Conditioning. Beijing: China Architecture & Building Press, in Chinese.