References
- Braun, K., Walker, K., Sürth, W., Löwenheim, H., Tropitzsch, A. 2019. Triphasic pulses in cochlear implant patients with facial nerve stimulation. Otology and Neurotology, 40(10): 1268–1277. doi:https://doi.org/10.1097/MAO.0000000000002398.
- Brummer, S.B., Turner, M.J. 1975. Electrical stimulation of the nervous system: The principle of safe charge injection with noble metal electrodes. Bioelectrochemistry and Bioenergetics, 2(1): 13–25. doi:https://doi.org/10.1016/0302-4598(75)80002-X.
- Frijns, J.H.M., De Snoo, S.L., Ten Kate, J.H. 1996. Spatial selectivity in a rotationally symmetric model of the electrically stimulated cochlea. Hearing Research, 95(1–2): 33–48. doi:https://doi.org/10.1016/0378-5955(96)00004-4.
- Gärtner, L., Büchner, A., Illg, A., Lenarz, T. 2021. Hidden electrode failure in a cochlear implant user. The Laryngoscope, 131(4): E1275–E1278. doi:https://doi.org/10.1002/lary.29023.
- Herrmann, D.P., Kalkman, R.K., Frijns, J.H.M., Bahmer, A. 2019. Investigating the reduction of the facial nerve stimulation in cochlear implants by triphasic pulses. 22. Jahrestagung Der Deutschen Gesellschaft Für Audiologie, March.
- Macherey, O., Carlyon, R.P., Van Wieringen, A., Deeks, J.M., Wouters, J. 2008. Higher sensitivity of human auditory nerve fibers to positive electrical currents. JARO - Journal of the Association for Research in Otolaryngology, 9(2): 241–251. doi:https://doi.org/10.1007/s10162-008-0112-4.
- Macherey, O., Van Wieringen, A., Carlyon, R.P., Deeks, J.M., Wouters, J. 2006. Asymmetric pulses in cochlear implants: effects of pulse shape, polarity, and rate. JARO - Journal of the Association for Research in Otolaryngology, 7(3): 253–266. doi:https://doi.org/10.1007/s10162-006-0040-0.
- Moon, A.K., Zwolan, T.A., Pfingst, B.E. 1993. Effects of phase duration on detection of electrical stimulation of the human cochlea. Hearing Research, 67(1–2): 166–178. doi:https://doi.org/10.1016/0378-5955(93)90244-U.
- Pieper, S.H., Brill, S., Bahmer, A. 2020. Loudness perception and dynamic range depending on interphase gaps of biphasic pulses in cochlear implants. Ear and Hearing, 41(5): 1251–1257. doi:https://doi.org/10.1097/AUD.0000000000000843.
- Van Den Abbeele, T., Noël-Petroff, N., Akin, I., Caner, G., Olgun, L., Guiraud, J., … Arnold, L. 2012. Multicentre investigation on electrically evoked compound action potential and stapedius reflex: how do these objective measures relate to implant programming parameters? Cochlear Implants International, 13(1): 26–34. doi:https://doi.org/10.1179/1754762810Y.0000000001.
- Van Horn, A., Hayden, C., Mahairas, A.D., Leader, P., Bush, M.L. 2020. Factors influencing aberrant facial nerve stimulation following cochlear implantation: A systematic review and meta-analysis. Otology and Neurotology, 41(8): 1050–1059. doi:https://doi.org/10.1097/MAO.0000000000002693.
- van Wieringen, A., Carlyon, R.P., Macherey, O., Wouters, J. 2006. Effects of pulse rate on thresholds and loudness of biphasic and alternating monophasic pulse trains in electrical hearing. Hearing Research, 220(1–2): 49–60. https://doi.org/https://doi.org/10.1016/j.heares.2006.06.015.