1,634
Views
14
CrossRef citations to date
0
Altmetric
Engineering and structural materials

Deposition of boron doped DLC films on TiNb and characterization of their mechanical properties and blood compatibility

, , , , , & show all
Pages 76-87 | Received 15 Jun 2016, Accepted 15 Nov 2016, Published online: 16 Jan 2017

References

  • Hang R, Qi Y. A study of biotribological behavior of DLC coatings and its influence to human serum albumin. Diamond Relat Mater. 2010;19:62–66.10.1016/j.diamond.2009.11.008
  • Sui JH, Gao ZY, Cai W, et al. DLC films fabricated by plasma immersion ion implantation and deposition on the NiTi alloys for improving their corrosion resistance and biocompatibility. Mater Sci Eng A. 2007;454-455:472–476.10.1016/j.msea.2006.11.133
  • Gutensohn K, Beythien C, Bau J, et al. In Vitro analyses of diamond-like carbon coated stents: reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res. 2000;99:577–585.10.1016/S0049-3848(00)00295-4
  • Jones MI, McColl IR, Grant DM, et al. Protein adsorption and platelet attachment and activation, on TiN, TiC, and DLC coatings on titanium for cardiovascular applications. J Biomed Mater Res. 2000;52:413–421.10.1002/(ISSN)1097-4636
  • Sui JH, Cai W. Effect of diamond-like carbon (DLC) on the properties of the NiTi alloys. Diamond Relat Mater. 2006;15:1720–1726.10.1016/j.diamond.2006.03.004
  • Takeno T, Shiota H, Sugawara T, et al. Highly adherent tungsten-containing diamond-like carbon (W-DLC) coating on a NiTi shape memory alloy under 10% tensile strain. Diamond Relat Mater. 2009;18:403–406.10.1016/j.diamond.2008.09.012
  • Bonetti LF, Capote G, Santos LV, et al. Adhesion studies of diamond-like carbon films deposited on Ti6Al4 V substrate with a silicon interlayer. Thin Solid Films. 2006;515:375–379.10.1016/j.tsf.2005.12.154
  • Ferrari AC, Kleinsorge B, Morrison NA, et al. Stress reduction and bond stability during thermal annealing of tetrahedral amorphous carbon. J Appl Phys. 1999;85:7191–7197.10.1063/1.370531
  • Tang XS, Wang HJ, Feng L, et al. Mo-doped DLC nanocomposite coatings with improved mechanical and blood compatibility properties. Appl Surf Sci. 2014;311:758–762.10.1016/j.apsusc.2014.05.155
  • Chhowalla M, Yin Y, Amaratunga GAJ, et al. Highly tetrahedral amorphous carbon films with low stress. Appl Phys Lett. 1996;69:2344–2346.10.1063/1.117519
  • Tan M, Zhu J, Han J, et al. Stress evolution of tetrahedral amorphous carbon upon boron incorporation. Scr Mater. 2007;57:141–144.10.1016/j.scriptamat.2007.03.036
  • He XM, Walter KC, Nastasi M. Plasma-immersion ion-processed boron-doped diamond-like carbon films. J Phys: Condens Matter. 2000;12:183–189.
  • Liza S, Ohtake N, Akasaka H, et al. Tribological and thermal stability study of nanoporous amorphous boron carbide films prepared by pulsed plasma chemical vapor deposition. Sci Technol Adv Mater. 2015;16:1–13.
  • Ahmad AA, Alsaad AM. Adhesive B-doped DLC films on biomedical alloys used for bone fixation. Bull Mater Sci. 2007;30:301–308.10.1007/s12034-007-0050-5
  • Koga K, Kaji A, Hirosaki K, et al. Cytotoxic evaluation of cubic boron nitride in human origin cultured cells. Toxicol in Vitro. 2006;20:1370–1377.10.1016/j.tiv.2006.06.008
  • Klepper CC, Williams JM, Truhan JJ Jr, et al. Tribo-mechanical properties of thin boron coatings deposited on polished cobalt alloy surfaces for orthopedic applications. Thin Solid Films. 2008;516:3070–3080.10.1016/j.tsf.2007.10.111
  • Lousinian S, Kalfagiannis N, Logothetidis S. Optical and surface characterization of amorphous boron nitride thin films for use as blood compatible coatings. Solid State Sci. 2009;11:1801–1805.10.1016/j.solidstatesciences.2009.05.010
  • Rebelo N, Fu R, Lawrenchuk M. Study of a nitinol stent deployed into anatomically accurate artery geometry and subjected to realistic service loading. J Mater Eng Perform. 2009;18:655–663.10.1007/s11665-009-9375-0
  • Wang YB, Zheng YF. Corrosion behaviour and biocompatibility evaluation of low modulus Ti-16Nb shape memory alloy as potential biomaterial. Mater Lett. 2009;63:1293–1295.10.1016/j.matlet.2009.02.062
  • McMahon RE, Ma J, Verkhoturov SV, et al. A comparative study of the cytotoxicity and corrosion resistance of nickel-titanium and titanium-niobium shape memory alloys. Acta Biomater. 2012;8:2863–2870.10.1016/j.actbio.2012.03.034
  • Cifre J, Puigdollers J, Polo MC, et al. Trimethylboron doping of CVD diamond thin films. Diamond Relat Mater. 1994;3:628–631.10.1016/0925-9635(94)90238-0
  • Tiainen V-M. Amorphous carbon as a bio-mechanical coating-mechanical properties and biological applications. Diamond Relat Mater. 2001;10:153–160.10.1016/S0925-9635(00)00462-3
  • Ferreira T, Rasband W. ImageJ user guide. 2012 [cited 2015 May 21]. Available from: http://imagej.nih.gov/ij/docs/guide/user-guide.pdf
  • Kitazaki Y, Hata T. Surface-chemical criteria for optimum adhesion. J Adhes. 1972;4:123–132.10.1080/00218467208072217
  • Hata T, Kitazaki Y, Saito T. Estimation of the surface energy of polymer solids. J Adhes. 1987;21:177–194.10.1080/00218468708074968
  • Černe L, Simončič B, Željko M. The influence of repellent coatings on surface free energy of glass plate and cotton fabric. Appl Surf Sci. 2008;254:6467–6477.
  • Jongwannasiri C, Moolsradoo N, Khantachawana A, et al. The comparison of biocompatibility properties between ti alloys and fluorinated diamond-like carbon films. Adv Mater Sci Eng. 2012;2012:1–8.10.1155/2012/724126
  • Tanaka Y, Kurashima K, Saito H, et al. In vitro short term platelet adhesion on various metals. J Artif Organs 2009;12:182–186.10.1007/s10047-009-0468-1
  • Hasebe T, Nagashima S, Kamijo A, et al. Hydrophobicity and non-thrombogenicity of nanoscale dual rough surface coated with fluorine-incorporated diamond-like carbon films: Biomimetic surface for blood-contacting medical devices. Diamond Relat Mater. 2013;38:14–18.10.1016/j.diamond.2013.06.001
  • Saito T, Hasebe T, Yohena S, et al. Antithrombogenicity of fluorinated diamond-like carbon films. Diamond Relat Mater. 2005;14:1116–1119.10.1016/j.diamond.2004.09.017
  • Roy RK, Choi HW, Yi JW, et al. Hemocompatibility of surface-modified, silicon-incorporated, diamond-like carbon films. Acta Biomater. 2009;5:249–256.10.1016/j.actbio.2008.07.031
  • Rusop M, Tian XM, Kinugawa T, et al. The effects of boron content in the target of pulsed laser deposition on the properties of boron doped amorphous carbon thin films. Mod Phys Lett B. 2004;18:1379–1393.10.1142/S0217984904007906
  • Pu J-C, Wang S-F, Lin C-L, et al. Characterization of boron-doped diamond-like carbon prepared by radio frequency sputtering. Thin Solid Films. 2010;519:521–526.10.1016/j.tsf.2010.07.018
  • Onate JI, Garcia A, Bellido V, et al. Deposition of hydrogenated B-C thin films and their mechanical and chemical characterization. Surf Coat Technol. 1991;49:548–553.10.1016/0257-8972(91)90115-D
  • Yu J, Wang EG, Ahn J, et al. Turbostratic boron carbonitride films produced by bias-assisted hot filament chemical vapor deposition. J Appl Phys. 2000;87:4022–4025.10.1063/1.372456
  • Wada Y, Yap YK, Yoshimura M, et al. The control of B-N and B-C bonds in BCN films synthesized using pulsed laser. Diamond Relat Mater. 2010;9:620–624.
  • Bendavid A, Martin PJ, Randeniya L, et al. The properties of fluorine containing diamond-like carbon films prepared by plasma-enhanced chemical vapor deposition. Diamond Relat Mater. 2009;18:66–71.10.1016/j.diamond.2008.09.021
  • Agathopoulos S, Nikolopoulos P. Wettability and interfacial interactions in bioceramic-body-liquid systems. J Biomed Mater Res. 1995;29:421–429.10.1002/(ISSN)1097-4636
  • Liu SB, Peyronnel A, Wang QJ, et al. An extension of the Hertz theory for three-dimensional coated bodies. Tribol Lett. 2005;18:303–314.10.1007/s11249-004-2757-4
  • Dresselhuis DM, Klok HJ, Stuart MAC, et al. Tribology of o/w emulsions under mouth-like conditions: determinants of friction. Food Biophys. 2007;2:158–171.10.1007/s11483-007-9040-9
  • Goodman SL, Grasel TG, Cooper SL, et al. Platelet shape change and cytoskeletal reorganization on polyurethaneureas. J Biomed Mater Res. 1989;23:105–123.10.1002/(ISSN)1097-4636
  • Allen RD, Zacharski LR, Widirstky ST, et al. Transformation and motility of human platelets: details of the shape change and release reaction observed by optical and electron microscopy. J Cell Biol. 1979;83:126–142.10.1083/jcb.83.1.126
  • Liu H, Zhang D, Shen F, et al. Hemocompatibility and anti-endothelialization of copper-titanium coating for vena cava filters. Surf Coat Technol. 2012;206:3501–3507.10.1016/j.surfcoat.2012.02.025
  • Hancock LF, Fagan SM, Ziolo MS. Hydrophilic, semipermeable membranes fabricated with poly(ethylene oxide)-polysulfone block copolymer. Biomaterials. 2000;21:725–733.10.1016/S0142-9612(99)00237-9
  • Wan GJ, Yang P, Shi XJ, et al. In vitro investigation of hemocompatibility of hydrophilic SiNx: H films fabricated by plasma-enhanced chemical vapor deposition. Surf Coat Technol. 2005;200:1945–1949.10.1016/j.surfcoat.2005.08.068
  • Hasebe T, Ishimaru T, Kamijo A, et al. Effects of surface roughness on anti-thrombogenicity of diamond-like carbon films. Diamond Relat Mater. 2007;16:1343–1348.10.1016/j.diamond.2006.12.009
  • Vroman L, Adams AL. Effect of heparin on reactions at aminated polymer-blood interfaces. J Colloid Interface Sci. 1969;31:188–195.10.1016/0021-9797(69)90325-7
  • Brash JL, Davidson VJ. Adsorption on glass and polyethylene from solutions of fibrinogen and albumin. Thromb Res. 1976;9:249–259.10.1016/0049-3848(76)90214-0
  • Massa TM, McClung WG, Yang ML, et al. Fibrinogen adsorption and platelet lysis characterization of fluorinated surface-modified polyetherurethanes. J Biomed Mater Res A. 2007;81:178–185.10.1002/(ISSN)1552-4965
  • Tsai WB, Grunkemeier JM, McFarland CD, et al. Platelet adhesion to polystyrene-based surfaces preadsorbed with plasmas selectively depleted in fibrinogen, fibronectin, vitronectin, or von Willebrand’s factor. J Biomed Mater Res A. 2002;60:348–359.10.1002/jbm.10048
  • Roach P, Farrar D, Perryl CC. Interpretation of protein adsorption: surface-induced conformational changes. J Am Chem Soc. 2005;127:8168–8173.10.1021/ja042898o
  • Slack SM, Horbett TA. Changes in fibrinogen adsorbed to segmented polyurethanes and hydroxyethylmethacrylate-ethylmethacrylate copolymers. J Biomed Mater Res. 1992;26:1633–1649.10.1002/(ISSN)1097-4636
  • Hashmi MSJ. Comprehensive Materials Processing. 1st ed. Oxford: Elsevier; 2014.
  • Huang N, Yang P, Leng YX, et al. Hemocompatibility of titanium oxide films. Biomaterials. 2003;24:2177–2187.10.1016/S0142-9612(03)00046-2
  • Koh LB, Rodriguez I, Venkatraman SS. The effect of topography of polymer surfaces on platelet adhesion. Biomaterials. 2010;31:1533–1545.10.1016/j.biomaterials.2009.11.022
  • Sutherland DS, Broberg M, Nygren H, et al. Influence of nano-scale surface topography and chemistry on the functional behavior of an adsorbed model macromolecule. Macromol Biosci. 2001;1:270–273.10.1002/(ISSN)1616-5195
  • Bahl S, Raj S, Vanamali S, Suwas S, Chatterjee K. Effect of boron addition and processing of Ti–6Al–4 V on corrosion behaviour and biocompatibility. Maters Techno Adv Biomaters. 2014;29:B64–B68.10.1179/1753555713Y.0000000118
  • Weber J, O’brien B. Boron-enhanced shape memory endoprostheses. U.S. Patent No. 11, 777,729 issued 2014 Mar 12.