An Improved Directional Sensor for On-line Partial Discharge Measurement in Overhead Covered Conductors

, , , , &
Pages 1543-1550 | Received 21 Jul 2015, Accepted 08 Feb 2016, Published online: 15 Aug 2016

References

  • Pihler, J., and Ticar, I., “Design of systems of covered overhead conductors by means of electric field calculation,” IEEE Trans. Power Del., Vol. 20, No. 2, pp. 807–814, 2005.
  • Hashmi, G.M., Lehtonen, M., and Nordman, M., “Modeling and experimental verification of on-line PD detection in MV covered-conductor overhead networks,” IEEE Trans. Dielectr. Electr. Insul., Vol. 17, No. 1, pp. 167–180, 2010.
  • Hashmi, G.M., and Lehtonen, M., “On-line PD detection for condition monitoring of covered-conductor overhead distribution networks—a literature survey,” 2nd International Conference on Electrical Engineering, pp. 237–242, Lahore, Pakistan, 25–26 March 2008.
  • Brian, W., Wood Pole Overhead Lines, 1st ed., London, UK: IET Press, pp. 143–155, 2005.
  • Nobrega, A.M., Martinez, M.L. B., and De Queiroz, A.A. A., “Analysis of the XLPE insulation of distribution covered conductors in Brazil,” J. Mater. Eng. Perform., Vol. 23, No. 3, pp. 723–735, 2014.
  • Chen, W.J., Gu, S.Q., He, J.L., and Yin, B., “Development of arc-guided protection devices against lightning breakage of covered conductors on distribution lines,” IEEE Trans. Power Del., Vol. 25, No. 1, pp. 196–205, 2010.
  • Pakonen, P., “Characteristics of partial discharges caused by trees in contact with covered conductor lines,” IEEE Trans. Dielectr. Electr. Insul., Vol. 15, No. 6, pp. 1626–1633, 2008.
  • Mardiana, R., and Su, C.Q., “Phase difference method for two-end partial discharge locating system of power cables,” Electr. Power Compon. Syst., Vol. 39, No. 9, pp. 863–878, 2011.
  • Isa, M., Elkalashy, N.I., Lehtonen, M., Hashmi, G.M., and Elmusrati, M.S., “Multi-end correlation-based PD location technique for medium voltage covered-conductor lines,” IEEE Trans. Dielectr. Electr. Insul., Vol. 19, No. 3, pp. 936–946, 2012.
  • Fernando, S.C., Rowe, W.S. T., and Wong, K.L., “Long wire antenna-like behavior of uninsulated overhead distribution cables,” IEEE Trans. Power Del., Vol. 27, No. 3, pp. 1116–1123, 2012.
  • Tungkanawanich, A., Kawasaki, Z.I., Abe, J., and Matsuura, K., “Location of partial discharge source on distribution line by measuring emitted pulse-train electromagnetic waves,” Power Engineering Society Winter Meeting, pp. 2453–2458, Singapore, 23–27 January 2000.
  • Bengtsson, T., Leijon, M., and Ming, L., “Directivity of acoustic-signals from partial discharges in oil,” IEEE Proc. Sci. Meas. Technol., Vol. 142, No. 1, pp. 85–88, 1995.
  • Pommerenke, D., Strehl, T., Heinrich, R., Kalkner, W., Schmidt, F., and Weissenberg, W., “Discrimination between internal PD and other pulses using directional coupling sensors an HV cable systems,” IEEE Trans. Dielectr. Electr. Insul., Vol. 6, No. 6, pp. 814–824, 1999.
  • Lundback, J., Nordebo, S., and Biro, T., “A digital directional coupler with applications to partial discharge measurements,” IEEE Trans. Instrum. Meas., Vol. 57, No. 11, pp. 2561–2567, 2008.
  • Stone, G.C., “Partial discharge diagnostics and electrical equipment insulation condition assessment,” IEEE Trans. Dielectr. Electr. Insul., Vol. 12, No. 5, pp. 891–904, 2005.
  • Sack, K., and Su, C.Q., “A non-contact directional sensor for partial discharge measurements,” IEEE International Symposium on Electrical Insulation (ISEI), San Diego, CA, 6–9 June 2010.
  • Study of direction identification of partial discharge using multi small loop sensors,” International Symposium on Electrical Insulating Materials (ISEIM), pp. 245–248, Niigata, Japan, 1–5 June 2014.
  • Gong, D., Sun, J., and Zhao, Z., “Research on directional coupler measurement in partial discharge monitoring of XLPE cable,” International Symposium on Electrical Insulating Materials (ISEIM), pp. 253–256, Niigata, Japan, 1–5 June 2014.
  • Shafiq, M., Amjad Hussain, G., Lehtonen, M., Hyv nen, P., and Elkalashy, N.I., “Integration of online proactive diagnostic scheme for partial discharge in distribution networks,” IEEE Trans. Dielectr. Electr. Insul., Vol. 22, No. 1, pp. 436–447, 2015.
  • Hemmati, E., and Shahrtash, S.M., “Investigation on Rogowski coil performance for structuring its design methodology,” IET Sci. Meas. Technol., Vol. 7, No. 6, pp. 306–314, 2013.
  • Tumanski, S., “Induction coil sensors—a review,” Meas. Sci. Technol., Vol. 18, No. 3, pp. 31–46, 2007.
  • Hashmi, G.M., Lehtonen, M., and Nordman, M., “Calibration of on-line partial discharge measuring system using Rogowski coil in covered-conductor overhead distribution networks,” IET Sci. Meas. Technol., Vol. 5, No. 1, pp. 5–13, 2011.
  • Argueso, M., Robles, G., and Sanz, J., “Implementation of a Rogowski coil for the measurement of partial discharges,” Rev. Sci. Instrum., Vol. 76, No. 6, 2005.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.