174
Views
19
CrossRef citations to date
0
Altmetric
APPLIED STUDIES

Quantitative Fit Testing Techniques and Regulations for Tight-Fitting Respirators: Current Methods Measuring Aerosol or Air Leakage, and New Developments

, &
Pages 219-228 | Published online: 18 Jun 2010

References

  • National Institute for Occupational Safety and Health (NIOSH) . 1987 . Guide to Industrial Respiratory Protection 3 – 123 . Washington , DC : Government Printing Office. . (DHHS/NIOSH pub. no. 87–116)
  • Colton , C. E. , Birkner , L. R. and Brosseau , L. M. , eds. 1991 . Respiratory Protection: A Manual and Guideline, , 2nd ed. Fairfax , VA : American Industrial Hygiene Association. .
  • National Institute for Occupational Safety and Health (NIOSH) . 1987 . Respirator Decision Logic 50 – 51 . Washington , DC : Government Printing Office. . (DHHS/NIOSH pub. no. 87–108)
  • Crutchfield , C. D. and Van Ert , M. D. 1993 . An examination of issues affecting the current state of quantitative respirator fit testing . J. Int. Soc. Respir. Prot. , 11 ( 2 ) : 5 – 18 .
  • da Roza , R. A. , Biermann , A. H. , Foote , K. L. McCormack , C. 1991 . Evaluation of Portacount for determining respirator fit factors, Part III: Human subject tests and comparison with an aerosol photometer . J. Int. Soc. Respir. Prot. , 9 ( 3 ) : 22 – 37 .
  • Oestenstad , R. K. and Graffeo , J. B. 1993–1994 . Determination of respirator fit by an aerosol method and a negative pressure method . J. Int. Soc. Respir. Prot. , 11 ( 3 ) : 6 – 14 .
  • Biermann , A. H. and Bergman , W. 1988 . Filter penetration measurements using a condensation nuclei counter and an aerosol photometer . J. Aerosol Sci. , 19 ( 4 ) : 471 – 483 .
  • Biermann , A. H. , da Roza , R. A. , Sawyer , S. R. Foote , K. L. 1991 . Evaluation of Portacount for determining respirator fit factors, Part II: Laboratory breathing machine tests of stability and comparison with an aerosol photometer . J. Int. Soc. Respir. Prot. , 9 ( 2 ) : 26 – 41 .
  • Crutchfield , C. D. , Park , D. L. , Hensel , J. L. Kvesic , M. K. 1995 . Determination of known respirator leakage using controlled negative pressure and ambient aerosol QNFT systems . Am. Ind. Hyg. Assoc. J: , 56 : 16 – 23 .
  • 1994 . “Asbestos,”. ” . In Code of Federal Regulations 34 – 42 . Title 29, Part 1910.1001
  • Myers , W. R. , Lenhart , S. W. , Campbell , D. and Provost , G. 1983 . Letter to the editor . Am. Ind. Hyg Assoc. J. , 44 : B25 – B26 .
  • AIHA's Respiratory Protection Committee . 1985 . Respirator performance terminology: Letter to the editor . Am. Ind. Hyg. Assoc. J. , 46 : B22 – B24 .
  • Brown , R. C. 1992 . Protection factors of respirators with special reference to dust respirators . J. Int. Soc. Respir. Prot. , 10 ( 1 ) : 5 – 33 .
  • da Roza , R. A. , Cadena-Fix , C. A. , Carlson , G. J. Hardis , K. E. 1983 . Reproducibility of respirator fit as measured by quantitative fitting tests . Am. Ind. Hyg. Assoc. J. , 44 : 788 – 794 .
  • Carpenter , D. and Willeke , K. 1988 . Quantitative respirator fit testing: dynamic pressure versus aerosol measurement . Am. Ind. Hyg. Assoc. J. , 49 : 492 – 496 .
  • Rose , J. C. , Oestenstad , R. K. and Rose , V. E. 1990 . A comparison of respirator fit factors determined by portable condensation nuclei counting and forward light-scattering photometric methods . Appl. Occup. Environ. Hyg. , 5 ( 11 ) : 792 – 797 .
  • Krishnan , U. , Willeke , K. , Juozaitis , A. Myojo , T. 1994 . Variation in quantitative respirator fit factors due to fluctuations in leak size during tit testing . Am. Ind. Hyg. Assoc. J. , 55 : 309 – 314 .
  • Krishnan , U. , Willeke , K. , Juozaitis , A. Lehtimaki , M. 1994 . Development of a dichotomous-flow quantitative fit test for half-mask and full-face-piece respirators . Am. Ind. Hyg. Assoc. J. , 55 : 223 – 229 .
  • Myers , W. R. , Allender , J. , Plummer , R. and Stobbe , T. 1986 . Parameters that bias the measurement of airborne concentration within a respirator . Am. Ind. Hyg Assoc. J. , 47 : 106 – 114 .
  • Myers , W. R. , Allender , J. R. , Iskander , W. and Stanley , C. 1988 . Causes of in-facepiece sampling bias—I. Half-facepiece respirators . Ann. Occup. Hyg. , 32 ( 3 ) : 345 – 359 .
  • Myers , W. R. and Allender , J. R. 1988 . Causes of in-facepiece sampling bias—II. Full-facepiece respirators . Ann. Occup. Hyg. , 32 ( 3 ) : 361 – 372 .
  • Holton , P. M. , Tackett , D. L. and Willeke , K. 1987 . Particle size-dependent leakage and losses of aerosol in respirators . Am. Ind. Hyg. Assoc. J. , 48 : 848 – 854 .
  • Holton , P. M. and Willeke , K. 1987 . The effect of aerosol size distribution and measurement method on respirator fit . Am. Ind. Hyg. Assoc. J. , 48 : 855 – 860 .
  • Willeke , K. and Krishnan , U. 1990 . Present procedures in quantitative respirator tit testing: problems and potential solutions . Appl. Occup. Environ. Hyg. , 5 ( 11 ) : 762 – 765 .
  • Oestenstad , R. K. , Perkins , J. L. and Rose , V. E. 1990 . Identification of faccscal leak sites on a half-mask respirator . Am. Ind. Hyg. Assoc. J. , 51 : 280 – 284 .
  • Burgess , W. A. , Silverman , L. and Stein , F. 1961 . A new technique for evaluating respirator performance . Am. Ind. Hyg. Assoc. J. , 22 : 422 – 429 .
  • Hyatt , E. C. , Pritchard , J. A. and Richards , C. P. 1972 . Respirator efficiency measurement using quantitative DOP man tests . Am. Ind. Hyg. Assoc. J. , 33 : 635 – 643 .
  • International Commission on Radiological Protection . 1966 . Deposition and retention models for internal dosimetry of the human respiratory tract . Health Phys. , 12 : 173 – 207 .
  • Chan , T. L. and Lippmann , M. 1980 . Experimental measurements and empirical modeling of the regional deposition of inhaled particles in humans . Am. Ind. Hyg. Assoc. J. , 41 : 399 – 109 .
  • Blanchard , J. D. and Willeke , K. 1984 . Total deposition of ultrafme sodium chloride particles in human lungs . J. Applied. Physiol.: Resp. Environ. Exer. Physiol. , 57 : 1850 – 1856 .
  • Johnson , B. R. , Bjork , K. A. and Weed , J. B. 1992 . A new sampling technique that allows quantitative fit testing by using the employee's own respirator . Am. Ind. Hyg. Assoc. J. , 53 : 776 – 79 .
  • Japuntich , D. A. and Johnston , A. R. 1987 . “Respirator Leak Tracking Using a Fluorescent Aerosol.” . Paper presented at the International Society for Respiratory Protection Conference . October 1987 , Toronto , Canada.
  • Hinds , W. and Kraske , G. 1987 . Performance of dust respirators with facial seal leaks: I. Experimental . Am. Ind. Hyg. Assoc. J. , 48 : 836 – 841 .
  • Myers , W. R. , Kim , H. and Kadrichu , N. 1991 . Effect of particle size on assessment of faceseal leakage . J. Int. Soc. Rcspir. Prot. , 9 ( 3 ) : 6 – 20 .
  • Oestenstad , R. K. , Hollenbeck , S. M. and Sherill , J. L. 1995 . “Variation of Respirator Fit Among the Exercises of a Quantitative Fit Test as Measured in a Respiratory Protection Program.” . Paper presented at the American Industrial Hygiene Conference & Exposition . May 1995 , Kansas City , Mo .
  • Lehtimaki , M. and Willeke , K. 1993 . “ Measurement methods. ” . In Aerosol Measurement Edited by: Willeke , K. and Baron , P. A. New York : Van Nostrand Reinhold. .
  • National Institute for Occupational Safety and Health (NIOSH) . 1976 . A Guide to Industrial Respiratory Protection Edited by: Pritchard , J. A. 133 – 135 . Cincinnati , OH : NIOSH. . (NIOSH 76–189)
  • Willeke , K. , Ayer , H. E. and Blanchard , J. D. 1981 . New methods for quantitative respirator fit testing with aerosols . Am. Ind. Hyp. Assoc. J. , 42 : 121 – 125 .
  • Sinclair , D. and Hoopes , G. S. 1975 . A continuous condensation nucleus counter . J. Aerosol Sci. , 6 ( 1 ) : 1 – 7 .
  • Ernstberger , H. G. , Gall , R. B. and Turok , C. W. 1988 . Experiments supporting the use of ambient aerosols for quantitative respirator fit testing . Am. Ind. Hyg. Assoc. J. , 49 : 613 – 619 .
  • Crosby , D. W. 1995 . Quantitative respirator fit testing—Which technology to use? [Newsletter Article] . Respir. Prot. Update , 6 ( 1 ) Jefferson, MD: Respirator Support Services, 1995
  • Carpenter , D. and Willeke , K. 1988 . Noninvasive, quantitative respirator fit testing through dynamic pressure measurement . Am. Ind. Hyg. Assoc. J. , 49 : 485 – 491 .
  • Crutchfield , C. D. , Eroh , M. P. and Van Ert , M. D. 1991 . A feasibility study of quantitative respirator fit testing by controlled negative pressure . Am. Ind. Hyg. Assoc. J. , 52 : 172 – 176 .
  • Crutchfield , C. D. , Murphy , R. W. and Van Ert , M. D. 1991 . A comparison of controlled negative pressure and aerosol quantitative respirator fit test systems by using fixed leaks . Am. Ind. Hyg. Assoc. J. , 52 : 249 – 251 .
  • Crutchfield , C. D. , Murphy , R. W. and Van Ert , M. D. 1993 . A comparison of controlled negative pressure and aerosol quantitative respirator fit test systems by using human subjects . Am. Ind. Hyg. Assoc. J: , 54 : 10 – 14 .
  • Crutchfield , C. D. , Pham , T. K. and Van Ert , M. D. 1993 . Determination of inspiratory pressure and flow rates for work rate-dependent quantitative respirator fit testing . Appl. Occup. Environ. Hyg. , 8 : 103 – 107 .
  • McGlone , J. T. 1988 . Quantitative respirator fit testing through dynamic pressure decay measurement . Appl. Ind. Hyg. , 3 ( 11 ) : F27 – F29 .
  • Xu , M. , Han , D. , Hangal , S. and Willeke , K. 1991 . Respirator fit and protection through determination of air and particle leakage . Ann. Occup. Hyg , 35 ( 1 ) : 13 – 24 .
  • Chen , C. C. and Willeke , K. 1992 . Characteristics of faceseal leakage in filtering facepieces . Am. Ind. Hyg. Assoc. J. , 53 : 533 – 539 .
  • Han , D. , Xu , M. , Foo , S. Pilacinski , W. 1991 . Simplified pressure method for respirator fit testing . Am. Ind. Hyg. Assoc. J. , 52 : 305 – 308 .
  • 1995 . “Respiratorv Protective Devices; Final Rules and Notice,” . Federal Register , 60 8 June : 110 30336 – 30398 .
  • Chen , C. C. , Lehtimaki , M. and Willeke , K. 1992 . Aerosol penetration through filtering facepieces and respirator cartridges . Am. Ind. Hyg. Assoc. J. , 53 : 566 – 574 .
  • Iverson , S. G. , Danisch , S. G. , Mullins , H. E. and Rudolph , S. K. 1992 . Validation of a quantitative fit test for dust/fume/mist respirators: Part I . Appl. Occup. Environ. Hyg. , 7 ( 3 ) : 161 – 167 .
  • Danisch , S. G. , Mullins , H. E. and Rhoe , C. R. 1992 . A quantitative fit test for dust/mist respirator: Part II . Appl. Occup. Environ. Hyg. , 7 ( 4 ) : 241 – 245 .
  • Myojo , T. , Willeke , K. and Chen , C. C. 1994 . Fit test for filtering facepieces: search for a low-cost, quantitative method . Am. Ind. Hyg. Assoc. J. , 55 : 797 – 805 .
  • Brown , R. C. and Vaughan , N. P. 1993 . Measurement of the leakage and fit factor of a filtering facepiece by commons monitoring of pressure pulsations . Am. Ind. Hyg. Assoc. J. , 54 : 409 – 116 .
  • Centers for Disease Control and Prevention . 1992 . NIOSH Recommended Guidelines for Personal Respiratory Protection of Workers in Health-Care Facilities Potentially Exposed to Tuberculosis. 32 – 55 . Washington , DC : Government Printing Office. .
  • Chen , C. C. and Willeke , K. 1992 . Aerosol penetration through surgical masks . Am. J. Infect. Control , 20 ( 4 ) : 177 – 184 .
  • Chen , S. K. , Vesley , D. , Brosseau , L. M. and Vincent , J. H. 1994 . Evaluation of single-use masks and respirators for protection of health care workers against mycobacterial aerosols . Am. J. Infect. Control , 22 ( 2 ) : 65 – 74 .
  • Weber , A. , Willeke , K. , Marchioni , R. Myojo , T. 1993 . Aerosol penetration and leakage characteristics of masks used in the health care industry . Am. J. Infect. Control , 21 ( 4 ) : 167 – 173 .
  • Laye , R. 1987 . Evaluation of a miniaturized condensation nucleus counter for measurement of respirator fit factor . J. Int. Soc. Respir. Prot. , 5 ( 3 ) : 1 – 7 .
  • Burnis , R. P. 1991 . A comparison of fit factors determined by an aerosol method and a dynamic negative pressure method Department of Environmental Health Sciences, University of Alabama at Birmingham. . Master's research project report
  • 1994 . “Cadmium,”. ” . In Code of Federal Regulations Title 204 – 208 . 29, Part 1910.1027
  • American National Standards Institute (ANSI) . 1992 . American National Standard for Respiratory Protection New York : ANSI. . (ANSI Z88.2–1992)
  • European Committee for Standardization . 1989 . “EN 136 Respiratory Protective Devices: Fullface Masks; Requirements, Testing, Marking.” Brussels , , Belgium : European Committee for Standardization. .
  • European Committee for Standardization . 1989 . “EN 140 Half-masks and Quarter-masks; Requirements, Testing, Marking.” Brussels , , Belgium : European Committee for Standardization. .
  • Standards Australia and Standards New Zealand . 1994 . AS/NZS 1716:1994, Respiratory Protective Devices. Australia : Standards Australia. . Homebush, NSW 2140
  • 1994 . “Occupational Safetv and Health Standards,”. ” . In Code of Federal Regulations 66 – 584 . Title 29, Part 1910
  • 1994 . “Safety and Health Regulations for Construction,”. ” . In Code of Federal Regulations 1 – 951 . Title 29, Part 1926
  • 1994 . “Respiratory Protection,”. ” . In Code of Federal Regulations 413 – 417 . Title 29, Part 1910.134
  • 1994 . “Respiratory Protection; Proposed Rule,” . Federal Register , 59 15 November : 219 58884 – 58956 .
  • Shepich , T. J. and Boggs , R. F. 8 February 1988 . Occupational Health and Safety Administration CD-ROM 8 February , Washington , DC (OSHA A95–3) through June 1995(1995)
  • Miles , J. B. and Sekulic , T. 25 September 1986 . Occupational Health and Safetv Administration CD-ROM 25 September , Washington , DC (OSHA A95–3) through June 1995, (1995)
  • June 24 1994 . “Quantitative Respirator Fit Testing Requirements and Compliance.” June 24 , Washington , DC : Memorandum from U. S. Department of Labor. . 20210, dated
  • Colton , C. E. 1994 . Qualitative fit testing or quantitative lit testing: Which one should you use? . 3M JobHealth Highlights , vol. 12 ( 2 ) : 3 – 4 . St. Paul, MN: 3M
  • Standards Australia and Standards New Zealand . 1994 . AS/NZS 1715.1994, Selection, Use and Maintenance of Respiratory Protective Devices. Australia : Standards Australia. . Homebush, NSW 2140
  • Canadian Standards Association . 1993 . Selection, Use, and Care of Respirators. Rexdale, Ontario , , Canada : Canadian Standards Association. . Z94.4–93
  • Occupational Safety and Health Administration . October 27 1980 . “29 CFR 1910.134(e)(5)-Respirator Fit Testing.” [Compliance Directive CPL 2–2.29] October 27 , Washington , DC
  • Johanson , R. E. and Morgan , M. S. 1984 . Some observations on frequency of respirator fit tests . Am. Ind. Hyg. Assoc. J. , 45 : 134 – 135 .
  • Hyatt , E. C. 1974 . Respiratory Studies for the National Institute for Occupational Safety and Health July 1, 1972 through June 3, 1975. Los Alamos , NM : Los Alamos Scientific Laboratory. . (LA-5620 PR)
  • Nelson , T. J. , Wilmes , D. P. and da Roza , R. A. 1994 . ANSI Z88.2 (1992): Practices for Respiratory Protection . Am. Ind. Hyg. Assoc. J. , 55 : 660 – 662 .
  • Nelson , T. J. March 29 1996 . “The ANSI Requirement for a Fit Factor of 10 Times APF.” March 29 , [Private Communication]. NIHS, Inc., 2401 East Mall, Ardentown, DE 19810
  • Dixon , S. W. and Nelson , T. J. 1984 . Workplace protection factors for negative pressure half-mask tacepiece respirator . J. Int. Soc. Respir. Prot. , 2 : 347 – 361 .
  • Colton , C. E. , Johnson , A. R. , Mullins , H. E. and Rhoe , C. R. 1989 . “Workplace Protection Factor Study on a Full Facepiece Respirator.” . Paper presented at the American Industrial Hygiene Conference . May 1989 , St. Louis , Mo .
  • 1994 . “Methylenedianiline,”. ” . In Code of Federal Regulations 461 – 168 . Title 29, Part 1910.1050.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.