  • Myers , W. R. , Allender , J. R. , Iskander , W. I. and Stanley , C. 1988 . Causes of in-facepiece sampling bias—II. Full-facepiece respirators . Ann. Occup. Hyg. , 32 : 361 – 372 .
  • Colton , C. E. , Johnston , A. R. , Mullins , H. E. , Rhoe , C. R. and Myers , W. R. 1990 . Workplace protection factor study on a half-mask dust/mist respirator . Presented at the American Industrial Hygiene Conference and Exposition . May 17 1990 , Orlando , Fla. . (OSHA H-049C-Ex. 1-146)
  • Colton , C. E. and Mullins , H. E. 1990 . Workplace protection factor study on a half mask respirator in a brass foundry . Paper Presented at the American Industrial Hygiene Conference and Exposition . May 15 1990 , Orlando , Fla. . (OSHA H-049C Ex. 1-146)
  • Johnston , A. R. and Mullins , H. E. 1987 . Workplace protection factor study for airborne metal dusts . Paper presented the American Industrial Hygiene Conference and Exposition . June 4 1987 , Orlando , Fla. . Montreal , , Canada (OSHA H-049C Ex. 1-146)
  • Colton , C. E. and Mullins , H. E. 1992 . Respirator workplace protection factors for a half-mask dust/mist/fume respirator . Poster presented at the American Industrial Hygiene Conference and Exposition . May 17 1992 , Orlando , Fla., Salt Lake City, Utah . (OSHA H-049C Ex. 1-146)
  • Nelson , T. J. and Dixon , S. W. 1985 . Respirator protection factors for asbestos, Parts I & II . Presented at the American Industrial Hygiene Conference and Exposition . May 19–24 1985 , Las Vegas , Nev. .
  • Graboury , A. and Burd , D. H. 1993 . Workplace protection factor evaluation of respiratory protective equipment in a primary aluminum smelter . Appl. Occup. Environ. Hyg. , 8 : 19 – 25 .
  • Gosselink , D. W. , Wilmes , D. P. and Mullins , H. E. 1986 . Workplace protection factor study for airborne asbestos . Presented at the American Industrial Hygiene Conference and Exposition . May 10–15 1986 , Dallas , Texas .
  • Dixon , S. W. and Nelson , T. J. 1984 . Workplace protection factors for negative pressure half-mask facepiece respirators . J. Int. Soc. Respir. Prot. , 2 : 347 – 361 .
  • Meyers , W. R. and Zhuang , Z. January 1993 . Workplace Protection Factor Study Conducted with Half Facepiece Class Respirators at Three Brass Foundries , January , Washington , DC : National Paint and Coatings Association .
  • Colton , C. E. 1990 . “3M 9970 Summary,” 3M internal ocrrespondence, November 26
  • Hinds , W. C. and Kraske , G. 1987 . Performance of dust respirators with facial seal leaks: I. experimental . Am. Ind. Hyg. Assoc. J. , 48 : 836 – 841 .
  • Myers , W. R. , Kim , H. and Kadrichu , N. 1991 . Effect of particle size on assessment of faceseal leakage . J. Int. Soc. Respir. Prot. , 9 : 6 – 21 .
  • Holton , P. M. , Tackett , D. L. and Willeke , K. 1987 . Particle size-dependent leakage and losses of aerosols in respirators . Am. Ind. Hyg. Assoc. J. , 48 : 848 – 854 .
  • Myers , W. R. , Zhuang , Z. , Nelson , T. J. , Sides , S. and Wilmes , D. 1995 . Field performance measurements of half-facepiece respirators-study protocol . Am. Ind. Hyg. Assoc. J. , 56 : 765 – 775 .
  • Myers , W. R. and Zhuang , Z. 1996 . Field performance measurements of half-facepiece respirators: Foundry operations . Am. Ind. Hyg. Assoc. J. , 57 : 166 – 174 .
  • Janssen , L. L. , Nelson , T. J. and Cuta , K. T. Workplace protection factors for an N95 filtering facepiece respirator . J. Occup. Environ. Hyg. , (In Press.)
  • Janssen , L. L. , Bidwell , J. O. , McCullough , N. V. and Nelson , T. J. Performance of an N95 Filtering Facepiece Respirator in a Grinding Operation . J. Int. Soc. Respir. Prot , (Submitted)
  • Johnston , A. R. , Myers , W. R. , Colton , C. E. , Birkner , J. S. and Campbell , C. E. 1992 . Review of respirator performance testing in the workplace: Issues and concerns . Am. Ind. Hyg. Assoc. J. , 53 : 705 – 712 .
  • 2006 . “Assigned Protection Factors; Final Rule,” . Federal Register , 71 24 August : 164 50122 – 50192 .
  • 2005 . “Respiratory Protection,” . Code of Federal Regulations , : 419 – 444 . Title 29 (6), Section 1910.134
  • American Industrial Hygiene Association (AIHA) . 2001 . American National Standard Respirator for Fit Testing Methods , Fairfax , Va. : AIHA . (ANSI Z 88.10) [Standard]
  • Myers , W. R. and Hornung , R. W. 1993 . Evaluation of new in-facepiece sampling procedures for full and half facepieces . Ann. Occup. Hyg , 37 ( 2 ) : 151 – 166 .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.