139
Views
5
CrossRef citations to date
0
Altmetric
Original Articles

Verifying Interpretive Criteria for Bioaerosol Data Using (Bootstrap) Monte Carlo Techniques

&
Pages 85-93 | Published online: 19 Dec 2007

REFERENCES

  • Fung , F. and Hughson , W. G. 2003 . Health effects of indoor fungal bioaerosol exposure . Appl. Occup. Environ. Hyg. , 18 : 535 – 544 .
  • Gots , R. E. , Layton , N. J. and Pirages , W. W. 2003 . Indoor health: Background levels of fungi . Am. Ind. Hyg. Assoc. J. , 64 : 427 – 438 .
  • Horner , W. E. , Worthan , A. G. and Morey , P. R. 2004 . Air and dustborne mycoflora in houses free of water damage and fungal growth . Appl. Environ. Microbiol. , 70 : 6394 – 6400 .
  • Kuhn , R. C. , Trimble , M. W. , Vasanthi , H. , Lee , M. and Nassof , R. S. 2005 . Prevalence and airborne spore levels of Stachybotrys spp. in 200 houses with water incursions in Houston, Texas . Can. J. Microbiol , 51 : 25 – 28 .
  • MacIntosh , D. L. , Brightman , H. S. Baker , B. J. 2006 . Airborne fungal spores in a cross sectional study of office buildings . J. Occup. Environ. Hyg. , 3 : 379 – 389 .
  • Mahooti-Brooks , N. , Storey , E. , Yang , C. , Simcox , N. J. , Turner , W. and Hodgson , M. 2004 . Characterization of mold and moisture indicators in the home . J. Occup. Environ. Hyg. , 1 : 826 – 839 .
  • Niemeier , R. T. , Sivasubramani , S. K. , Reponen , T. and Grinshpun , S. A. 2006 . Assessment of fungal contamination in mold homes: Comparison of different methods . J. Occup. Environ. Hyg. , 3 : 262 – 273 .
  • Spicer , R. C. and Gangloff , H. J. 2000 . Limitations in application of Spearman's Rank Correlation to bioaerosol sampling data . Am. Ind. Hyg. Assoc. J. , 61 : 361 – 366 .
  • Baxter , D. M. , Perkins , J. L. , McGhee , C. R. and Selzer , J. M. 2005 . A regional comparison of mold spore concentrations outdoors and inside “clean” and “mold contaminated” Southern California buildings . J. Occup. Environ. Hyg. , 2 : 8 – 18 .
  • Flannigan , B . Guidelines for evaluation of airborne microbial contamination of buildings . Proceedings of the International Conference: Fungi and Bacteria in Indoor Air Environments Saratoga Springs . 1994 , New York . Edited by: Johanning , E. and Yang , C. S. pp. 123 – 130 . Latham , N.Y. : Eastern New York Occupational Health Program .
  • Kemp , P. C. , Neumeister-Kemp , H. G. , Esposito , B. , Lysek , G. and Murray , F. 2003 . Changes in airborne fungi from the outdoors to indoor air; large HVAC systems in non problem buildings in two climates . Am. Ind. Hyg. Assoc. J. , 64 : 269 – 275 .
  • Lappalainen , S. , Lindroos , O. and Reijula , K. 1999 . “ Concentrations of airborne viable spores of fungi and Actinomycetes in mold-damaged offices and schools ” . In Bioaerosols, Fungi, and Mycotoxins: Health Effects, Assessment, Prevention and Control , Edited by: Johanning , E. 616 – 619 . Albany , N.Y. : Eastern New York Occupational & Environmental Health Center .
  • Meklin , T. , Hyvarinen , A. Toivola , M. 2003 . Effect of building frame and moisture damage on microbial indoor air quality in school buildings . Am. Ind. Hyg. Assoc. J. , 64 : 108 – 116 .
  • Miller , J. D. 2001 . “ Mycological investigations of indoor environments ” . In Microorganisms in Home and Indoor Work Environments , 231 – 246 . Boca Raton , Fla. : CRC Press .
  • Miller , J. D. , Dales , M. D. and White , J. 1999 . “ Exposure measures for studies of mold and dampness and respiratory health ” . In Bioaerosols, Fungi, and Mycotoxins: Health Effects, Assessment, Prevention and Control , Edited by: Johanning , E. 298 – 305 . Albany, New York : Eastern New York Occupational & Environmental Health Center .
  • Mullins , J. 2001 . “ Microorganisms in outdoor air ” . In Microorganisms in Home and Indoor Work Environments , Edited by: Flannigan , B. , Samson , R. A. and Miller , J. D. 3 – 16 . Boca Raton , Fla. : CRC Press .
  • Rand , T. G. 1999 . “ An assessment of mold contamination problems in Atlantic Canada Schools: Mold burdens, amplifying sites and benefits of proactive school Inspection policies ” . In Bioaerosols, Fungi, and Mycotoxins: Health Effects, Assessment, Prevention and Control , Edited by: Johanning , E. 581 – 592 . Albany , N.Y. : Eastern New York Occupational & Environmental Health Center .
  • Shelton , B. K. , Kirkland , H. , Flanders , W. D. and Morris , G. K. 2002 . Profiles in airborne fungi in buildings and outdoor environments in the United States . Appl. Environ. Microbiol. , 68 : 1743 – 1753 .
  • Spurgeon , J. 2003 . A method for detecting fungal contamination in wall cavities . Am Ind. Hyg. Assoc. J. , 64 : 40 – 47 .
  • Ramachandran , G. , Adgate , J. L. , Banerjee , S. , Church , T. R. , Jones , D. , Frederickson , A. and Sexton , K. 2005 . Indoor air quality in two urban elementary schools—Measurements of airborne fungi, carpet allergens, CO2, temperature, and relative humidity . J. Occup. Environ. Hyg. , 2 : 553 – 566 .
  • Godish , T. J. and Godish , D. R. 2006 . Mold infestation of wet-spray-applied cellulose insulation . J. Air Waste Manage. Assoc. , 56 : 90 – 95 .
  • Spicer , R. C. and Gangloff , H. J. 2005 . Establishing site specific reference levels for fungi in outdoor air for building evaluation . J. Occup. Environ. Hyg. , 2 : 257 – 266 .
  • Spicer , R. C. and Gangloff , H. J. 2003 . Bioaerosol data distribution: Probability and Implications for sampling in evaluating problematic buildings . Appl. Occup. Environ. Hyg. , 18 : 584 – 590 .
  • Hung , L. L. , Miller , J. D. and Dillon , H. K. , eds. 2005 . “ Viable fungi and bacteria in air, bulk, and surface samples and legionella ” . In Guide for the Determination of Biological Contaminants in Environmental Samples, , 2nd Ed. , 109 – 110 . Fairfax , Va. : AIHA Press .
  • Macher , J. 1999 . “ Data analysis ” . In Bioaerosols Assessment and Control , Edited by: Macher , J. 13-1 – 13-16 . Cincinnati , Ohio : American Conference of Governmental Industrial Hygienists .
  • Mooney , C. Z. and Duval , R. D. 1993 . Bootstrapping: A Nonparametric Approach to Statistical Inference , 1 – 22 . Thousand Oaks , Calif. : Sage Publications .
  • Sobol , I. 1994 . “ Simulating random variables ” . In A Primer for the Monte Carlo Method , 2 – 33 . Boca Raton , Fla. : CRC Press .
  • Sobol , I. 1994 . “ Examples of the Application of the Monte Carlo Method ” . In A Primer for the Monte Carlo Method , 44 – 47 . Boca Raton , Fla. : CRC Press .
  • Davison , A. C. and Hinkley , D. V. 2003 . Tests in Bootsrap Methods and their Application , 136 – 190 . Cambridge , , England : Cambridge University Press .
  • New York City Department of Health . 2002 . Guidelines on Assessment and Remediation of Fungi in Indoor Environments , New York : New York City Department of Health .
  • Environmental Protection Agency (EPA) . March 2001 . Mold Remediation in Schools and Commercial Buildings , March , Washington , D.C. : EPA Office of Air and Radiation, Indoor Environments Division . (EPA 402-K-01-001)
  • Burge , H. , Macher , J. and Milton , D. 1999 . “ Data evaluation ” . In Bioaerosols: Assessment and Control , Edited by: Macher , J. 14-1 – 14-11 . Cincinnati , Ohio : American Conference of Governmental Industrial Hygienists .
  • Macher , J. , ed. 1999 . “ Data interpretation ” . In Bioaerosols: Assessment and Control , 7-1 – 7–15 . Cincinnati , Ohio : American Conference of Governmental Industrial Hygienists .

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.