REFERENCES
- National Institute of Occupational Safety and Health (NIOSH) . 1994 . “ Method 1501. Hydrocarbons, aromatic ” . In NIOSH Manual of Analytical Methods, , 4th ed. , Cincinnati, Ohio : NIOSH .
- Seko , T. and Onda , N. 1997 . Analysis of VOCs in air by automated tube sampling and thermal desorption GC-MS . Anal. Sci. , 13 ( Suppl ) : 437 – 442 .
- Wang , J. L. , Chen , S. W. and Chew , C. 1999 . Automated gas chromatography with cryogenic/sorbent trap for the measurement of volatile organic compounds in the atmosphere . J. Chromatogr. A , 863 ( 2 ) : 183 – 193 .
- Clausen , P. A. and Wolkoff , P. 1997 . Degradation products of Tenax TA formed during sampling and thermal desorption analysis: Indicators of reactive species indoors . Atmos. Environ. , 31 ( 5 ) : 715 – 725 .
- Tuduri , L. , Desauziers , V. and Fanlo , J. L. 2002 . Dynamic versus static sampling for the quantitative analysis of volatile organic compounds in air with polydimethylsiloxane-Carboxen solid-phase microextraction fibers . J. Chromatogr. A , 963 ( 1–2 ) : 49 – 56 .
- Mocho , P. , Larroque , V. and Desauziers , V. 2007 . Modelling of toluene solid-phase microextraction for indoor air sampling . Anal. Bioanal. Chem. , 388 ( 1 ) : 147 – 156 .
- Tuduri , L. , Desauziers , V. and Fanlo , J. L. 2003 . A simple calibration procedure for volatile organic compounds sampling in air with adsorptive solid-phase microextraction fibres . Analyst , 128 ( 8 ) : 1028 – 1032 .
- Larroque , V. , Desauziers , V. and Mocho , P. 2006 . Development of a solid phase microextraction (SPME) method for the sampling of VOC traces in indoor air . J. Environ. Monit. , 8 : 106 – 111 .
- Tuduri , L. , Desauziers , V. and Fanlo , J. L. 2001 . Potential of solid-phase microextraction fibers for the analysis of volatile organic compounds in air . J. Chromatogr. Sci. , 39 ( 12 ) : 521 – 529 .
- Tumbiolo , S. , Gal , J. F. , Maria , P. C. and Zerbinati , O. 2005 . SPME sampling of BTEX before GC/MS analysis: Examples of outdoor and indoor air quality measurements in public and private sites . Ann. Chim. , 95 : 757 – 766 .
- Tumbiolo , S. , Gal , J. F. , Maria , P. C. and Zerbinati , O. 2004 . Determination of benzene, toluene, ethylbenzene and xylenes in air by solid phase micro-extraction/gas chromatography/mass spectrometry . Anal. Bioanal. Chem. , 380 ( 5–6 ) : 824 – 830 .
- Parreira , F. V. , de Carvalho , C. R. and Cardeal , Z. D. 2002 . Evaluation of indoor exposition to benzene, toluene, ethylbenzene, xylene, and styrene by passive sampling with a solid-phase microextraction device . J. Chromatogr. Sci. , 40 ( 3 ) : 122 – 126 .
- Periago , J. F. and Prado , C. 2005 . Evolution of occupational exposure to environmental levels of aromatic hydrocarbons in service stations . Ann. Occup. Hyg. , 49 ( 3 ) : 233 – 240 .
- Chakroun , R. , Kaabachi , N. Hedhili , A. 2002 . Benzene exposure monitoring of Tunisian workers . J. Occup. Environ. Med. , 44 ( 12 ) : 1173 – 1178 .
- Brugnone , F. , Perbellini , L. , Romeo , L. , Cerpelloni , M. , Bianchin , M. and Tonello , A. 1999 . Benzene in blood as a biomarker of low level occupational exposure . Sci. Total Environ. , 235 ( 1–3 ) : 247 – 252 .
- Maria , P. C. , Gal , J. F. , Balza , M. , Pere-Trepat , E. , Tumbiolo , S. and Couret , J. M. 2002 . Using Thermogravimetry for weight loss monitoring of permeation tubes used for generation of trace concentration gas standards . Anal. Chem. , 74 ( 1 ) : 305 – 307 .
- Delcourt , J. , Guénier , J. P. and Muller , J. 1989 . Sampling of gaseous pollutants. INRS diffusive sampler. 1. Description 587 – 592 . Cahiers de Notes Documentaires. No. 137
- Zhou , S. N.S. , Zhang , X. , Ouyang , G. , Es-Haghi , A. and Pawliszyn , J. 2007 . On-fiber standardization technique for solid-coated solid-phase microextraction . Anal. Chem. , 79 ( 3 ) : 1221 – 1230 .
- Gorecki , T. , Yu , X. M. and Pawliszyn , J. 1999 . Theory of analyte extraction by selected porous polymer SPME fibres . Analyst , 124 : 643 – 649 .
- Griefahn , B. , Kunemund , C. and Gehring , U. 2001 . The impact of draught related to air velocity, air temperature and workload . Appl. Ergon. , 32 ( 4 ) : 407 – 417 .